Scintillation Fiber-Optic Detectors for Dosimetry of 60 MeV Proton Beam

Scintillation fiber-optic detectors (FODs) offer a compact, electrically passive, and versatile solution for real-time proton beam monitoring in clinical radiation therapy. In this work, we systematically investigate and compare FODs based on GAGG:Ce, Al2O3:C, and Al2O3:C,Mg crystal scintillators under identical proton irradiation conditions. The detectors were evaluated using a 60 MeV clinical proton beam over a dose range of 0.5–15 Gy, with radioluminescence spectra acquired at integration times as short as 70 ms. The GAGG:Ce-based FOD exhibited the highest signal intensity, a fast temporal response, and excellent stability under repeated irradiation cycles, enabling reliable real-time dose monitoring. In contrast, the FODs based on Al2O3:C and Al2O3:C,Mg demonstrated high sensitivity, reproducible dose–response characteristics, and a low effective atomic number (Zeff ≈ 11), providing near tissue-equivalent behavior. Mg co-doping modified the luminescence characteristics of Al2O3:C by enhancing the contribution of visible emission centers. However, under the present proton irradiation conditions, the overall RL signal remained lower than that of Al2O3:C while preserving good signal stability. All detector configurations maintained consistent performance across multiple irradiation cycles, with GAGG:Ce showing the lowest signal variation. Overall, these results demonstrate that scintillation FODs constitute a robust platform for proton beam diagnostics and dosimetry. GAGG:Ce-based detectors are shown to have promising potential for real-time proton beam monitoring, whereas sapphire-based detectors provide advantages for dosimetric applications where tissue equivalence is essential.

Authors

Institutions

Publication Details

Journal
Materials
Published
2026-09-01
DOI
https://doi.org/10.3390/ma19173724
Primary Topic
Advanced Radiotherapy Techniques
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Scintillation Fiber-Optic Detectors for Dosimetry of 60 MeV Proton Beam

P. Bilski, Anna Mrozik, Yu. Zorenko, Jan Swakoń et al.
Materials
Advanced Radiotherapy Techniques
article

Scintillation Fiber-Optic Detectors for Dosimetry of 60 MeV Proton Beam

P. Bilski, Anna Mrozik, Yu. Zorenko, Jan Swakoń, Janusz Winiecki, Mark Akselrod, Sandra Witkiewicz-Łukaszek, Damian Wróbel, Michał Sądel, Bogna Sobiech
article en

Abstract

Scintillation fiber-optic detectors (FODs) offer a compact, electrically passive, and versatile solution for real-time proton beam monitoring in clinical radiation therapy. In this work, we systematically investigate and compare FODs based on GAGG:Ce, Al2O3:C, and Al2O3:C,Mg crystal scintillators under identical proton irradiation conditions. The detectors were evaluated using a 60 MeV clinical proton beam over a dose range of 0.5–15 Gy, with radioluminescence spectra acquired at integration times as short as 70 ms. The GAGG:Ce-based FOD exhibited the highest signal intensity, a fast temporal response, and excellent stability under repeated irradiation cycles, enabling reliable real-time dose monitoring. In contrast, the FODs based on Al2O3:C and Al2O3:C,Mg demonstrated high sensitivity, reproducible dose–response characteristics, and a low effective atomic number (Zeff ≈ 11), providing near tissue-equivalent behavior. Mg co-doping modified the luminescence characteristics of Al2O3:C by enhancing the contribution of visible emission centers. However, under the present proton irradiation conditions, the overall RL signal remained lower than that of Al2O3:C while preserving good signal stability. All detector configurations maintained consistent performance across multiple irradiation cycles, with GAGG:Ce showing the lowest signal variation. Overall, these results demonstrate that scintillation FODs constitute a robust platform for proton beam diagnostics and dosimetry. GAGG:Ce-based detectors are shown to have promising potential for real-time proton beam monitoring, whereas sapphire-based detectors provide advantages for dosimetric applications where tissue equivalence is essential.

MaterialsVol. 19(17)
Oklahoma State University (US), Kazimierz Wielki University in Bydgoszcz (PL), University of Bydgoszcz (PL), Institute of Nuclear Physics, Polish Academy of Sciences (PL), Collegium Medicum in Bydgoszcz (PL)
Narodowe Centrum Nauki
Openalex Percentile: Top 12%
Advanced Radiotherapy Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.