Thermo-mechanical loading of innovative “Mini-skirt” preparation design versus conventional full-coverage maxillary central incisor preparation design: an in vitro study
Conventional full-coverage anterior crown preparations for zirconia often require substantial enamel and dentine reduction and may concentrate palatal-cervical stresses, risking marginal discrepancy and compromised seal. A conservative “Mini-skirt” (MS) design that positions the palatal finish line coronally (above the cingulum) could preserve tooth structure and enhance adhesive support, but its thermo-mechanical performance under thermal cycling and fatigue loading remains unclear. To evaluate whether a conservative MS anterior preparation, with a palatal finish line above the cingulum, improves the thermo-mechanical behavior of generation-5 zirconia crowns compared with a conventional full-coverage (CF) design. Sixty extracted maxillary central incisors were randomly assigned to MS or CF groups ( n = 30). Monolithic 4Y zirconia crowns were CAD/CAM-manufactured, air-abraded and adhesively luted. Specimens were thermocycled 10,000 times between 5 °C and 55 °C, then obliquely loaded at 45° for 1.7 × 10⁶ cycles (50 N, 2 Hz); survivors underwent static fracture testing (0.5 mm·min⁻¹). Marginal gaps were quantified from silicone replicas; failures were classified Grades I–IV (restorable = I–III). Finite-element models (~ 1.3 M elements) reproduced boundary conditions to map stress. The MS preparation endured thermo-mechanical ageing markedly better than CF: 93.3% (28/30) versus 53.3% (16/30) of crowns completed the fatigue protocol (χ² = 9.01, p = 0.003). Post-fatigue, median fracture load increased from 860 N (IQR 780–930 N) in CF to 1,140 N (1,030–1,260 N) in MS ( p < 0.05). Mean marginal gap contracted from 112 ± 21 μm to 67 ± 14 μm (40% reduction, p < 0.001). Restorable fractures predominated in MS (83%) but were minority in CF (37%); catastrophic Grade IV failures fell from 63% to 17% (χ² = 13.6, p < 0.001). Finite-element analysis corroborated the laboratory data, showing a 40% drop in peak palatal-cervical von Mises stress (415 to 250 MPa) and parallel reductions in tensile dentine stress and cement-shear hotspots. Within the limitations of this in vitro study, the MS preparation showed favorable biomechanical performance under simulated thermo-mechanical loading. These findings provide a preclinical rationale for further investigation of the MS design, although long-term clinical studies are required before definitive clinical recommendations can be made.
Authors
- O Badran (ORCID: https://orcid.org/0000-0003-2870-0108)
- Dana El Ballouli
- Mohammad Rayyan (ORCID: https://orcid.org/0000-0002-4005-6362)
- Alaa Naguib (ORCID: https://orcid.org/0000-0003-1146-2123)
- Maha Fouad
- Mohamed Sayed (ORCID: https://orcid.org/0000-0002-1491-5688)
- Sahar Mokhtar
- Ehab Farghaly
- Nasser Hussein Shaheen
- Radwa Ibrahim Eltahawi
- Hatem M. Ibrahim
- Rana Walid Tawil (ORCID: https://orcid.org/0009-0008-5203-2764)
- Omayma Tantawy Said Mohammed (ORCID: https://orcid.org/0000-0002-1983-6399)
- Mohammed Moustafa Shalaby (ORCID: https://orcid.org/0000-0003-2673-0397)
- Mohamed B. A. Badawy (ORCID: https://orcid.org/0000-0002-2107-2586)
Institutions
- Suez University (EG)
- Cairo University (EG)
- British University in Egypt (EG)
- Misr University for Science and Technology (EG)
- Nahda University (EG)
- Magrabi Hospitals and Centers (SA)
- Sulaiman Al Rajhi Colleges (SA)
- Modern University for Information and Technology (EG)
- Dar Al Uloom University (SA)
- Ahram Canadian University (EG)
- Minia University (EG)
Publication Details
- Journal
- BMC Oral Health
- Published
- 2026-09-01
- DOI
- https://doi.org/10.1186/s12903-026-09357-5
- Primary Topic
- Dental materials and restorations
- Type
- article
- Field-Weighted Citation Impact
- 0.00