Molecular Characterization of the Air Microbiome and Associated Toxicological Hazards in a Zoological Garden

This study presents the first comprehensive characterization of the airborne microbiome in a zoological garden and its comparison with the surrounding atmospheric environment. The aim of this study was to evaluate potential human health hazards associated with occupational and visitor exposure in zoo environments across 24 sampling locations. The assessment included measurements of particulate matter (PM) and gaseous pollutants, microbiological contamination of air, surfaces, settled dust, and selected items of personal protective equipment (PPE). In addition, the cytotoxic potential of settled dust samples was evaluated using A549 human lung epithelial cells. The highest concentrations of airborne PM ranged from 0.250 mg/m3 for PM1 to 0.278 mg/m3 for PM10. The concentrations of chemical contaminants varied depending on the sampling location. Airborne bacterial counts ranged from 1.1 × 102 to 3.0 × 102 colony-forming units (CFU)/m3 in employee areas and from 2.2 × 103 to 1.5 × 104 CFU/m3 in visitor areas. The average microbial contamination of surfaces in both employee and visitor areas was 4.3 CFU/cm2. Amplicon sequencing revealed that the airborne microbiome was dominated by bacterial taxa belonging to Bacillota, Pseudomonadota, and Actinomycetota, as well as fungal taxa representing the phyla Ascomycota and Basidiomycota. Settled dust samples exhibited variable cytotoxicity toward A549 cells, with half-maximal inhibitory concentration (IC50) values ranging from 13.1 to 53.5 mg/mL. The findings provide novel insights into the molecular composition of zoo-associated airborne microbial communities and their potential implications for environmental health risk assessment and hygiene management practices in zoological gardens.

Authors

Institutions

Publication Details

Journal
International Journal of Molecular Sciences
Published
2026-09-01
DOI
https://doi.org/10.3390/ijms27177839
Primary Topic
Indoor Air Quality and Microbial Exposure
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Molecular Characterization of the Air Microbiome and Associated Toxicological Hazards in a Zoological Garden

Agnieszka Maher, Katarzyna Majchrzycka, Tomasz Grzyb, Justyna Szulc et al.
International Journal of Molecular Sciences
Indoor Air Quality and Microbial Exposure
article

Molecular Characterization of the Air Microbiome and Associated Toxicological Hazards in a Zoological Garden

Agnieszka Maher, Katarzyna Majchrzycka, Tomasz Grzyb, Justyna Szulc, Adriana Nowak, Małgorzata Okrasa, Magdalena Janiszewska, Elżbieta Tarczyńska
article en

Abstract

This study presents the first comprehensive characterization of the airborne microbiome in a zoological garden and its comparison with the surrounding atmospheric environment. The aim of this study was to evaluate potential human health hazards associated with occupational and visitor exposure in zoo environments across 24 sampling locations. The assessment included measurements of particulate matter (PM) and gaseous pollutants, microbiological contamination of air, surfaces, settled dust, and selected items of personal protective equipment (PPE). In addition, the cytotoxic potential of settled dust samples was evaluated using A549 human lung epithelial cells. The highest concentrations of airborne PM ranged from 0.250 mg/m3 for PM1 to 0.278 mg/m3 for PM10. The concentrations of chemical contaminants varied depending on the sampling location. Airborne bacterial counts ranged from 1.1 × 102 to 3.0 × 102 colony-forming units (CFU)/m3 in employee areas and from 2.2 × 103 to 1.5 × 104 CFU/m3 in visitor areas. The average microbial contamination of surfaces in both employee and visitor areas was 4.3 CFU/cm2. Amplicon sequencing revealed that the airborne microbiome was dominated by bacterial taxa belonging to Bacillota, Pseudomonadota, and Actinomycetota, as well as fungal taxa representing the phyla Ascomycota and Basidiomycota. Settled dust samples exhibited variable cytotoxicity toward A549 cells, with half-maximal inhibitory concentration (IC50) values ranging from 13.1 to 53.5 mg/mL. The findings provide novel insights into the molecular composition of zoo-associated airborne microbial communities and their potential implications for environmental health risk assessment and hygiene management practices in zoological gardens.

International Journal of Molecular SciencesVol. 27(17)
Lodz University of Technology (PL), Wrocław Zoo (PL), Central Institute for Labour Protection (PL)
Life in Land
Openalex Percentile: Top 12%
Indoor Air Quality and Microbial Exposure
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.