The introduction of MiRA (Micro Robotic Access) for subclavicular neck dissection

Robotic-assisted surgery has progressively expanded in head and neck diseases, providing minimally invasive alternatives to conventional transcervical approaches while improving visualization, precision, ergonomics, and cosmetic outcomes. The MiRA (Micro Robotic Access) pneumoneck technique was developed as a fully robotic subclavicular approach for lateral neck dissection. The technique combines small subclavicular ports, carbon dioxide insufflation to create a stable cervical working space, and the Asson assistant port system to optimize pressure stability and auxiliary instrument use. The MiRA pneumoneck technique was applied in a female patient with squamous cell carcinoma of the oral floor who underwent a right selective lateral neck dissection. Four subclavicular incisions were created for robotic and assistant ports. Pneumoneck was established using CO 2 insufflation, and the procedure was performed with the Da Vinci Xi Surgical System. Robotic dissection enabled en-bloc clearance of cervical levels I–III while preserving major neurovascular structures. The specimen was removed through the assistant port. Postoperative recovery was uneventful, with no major complications, early mobilization, and discharge on postoperative day 4. Compared with previously described robotic neck approaches, the MiRA pneumoneck technique represents a fully remote-access strategy for lateral neck surgery without visible cervical incisions. CO 2 insufflation improves visualization and instrument maneuverability, while the Asson system reduces gas leakage and enhances procedural versatility. The MiRA pneumoneck technique represents a further evolution in minimally invasive robotic neck surgery. Further studies are required to evaluate reproducibility, oncologic safety, cost-effectiveness, and long-term outcomes.

Authors

Institutions

Publication Details

Journal
International Journal of Oral and Maxillofacial Surgery
Published
2026-09-01
DOI
https://doi.org/10.1016/j.ijom.2026.08.029
Primary Topic
Surgical Simulation and Training
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

The introduction of MiRA (Micro Robotic Access) for subclavicular neck dissection

S. Crimi, S. Battaglia, A. Bianchi, M. Grimaldi
International Journal of Oral and Maxillofacial Surgery
Surgical Simulation and Training
article

The introduction of MiRA (Micro Robotic Access) for subclavicular neck dissection

S. Crimi, S. Battaglia, A. Bianchi, M. Grimaldi
article en

Abstract

Robotic-assisted surgery has progressively expanded in head and neck diseases, providing minimally invasive alternatives to conventional transcervical approaches while improving visualization, precision, ergonomics, and cosmetic outcomes. The MiRA (Micro Robotic Access) pneumoneck technique was developed as a fully robotic subclavicular approach for lateral neck dissection. The technique combines small subclavicular ports, carbon dioxide insufflation to create a stable cervical working space, and the Asson assistant port system to optimize pressure stability and auxiliary instrument use. The MiRA pneumoneck technique was applied in a female patient with squamous cell carcinoma of the oral floor who underwent a right selective lateral neck dissection. Four subclavicular incisions were created for robotic and assistant ports. Pneumoneck was established using CO 2 insufflation, and the procedure was performed with the Da Vinci Xi Surgical System. Robotic dissection enabled en-bloc clearance of cervical levels I–III while preserving major neurovascular structures. The specimen was removed through the assistant port. Postoperative recovery was uneventful, with no major complications, early mobilization, and discharge on postoperative day 4. Compared with previously described robotic neck approaches, the MiRA pneumoneck technique represents a fully remote-access strategy for lateral neck surgery without visible cervical incisions. CO 2 insufflation improves visualization and instrument maneuverability, while the Asson system reduces gas leakage and enhances procedural versatility. The MiRA pneumoneck technique represents a further evolution in minimally invasive robotic neck surgery. Further studies are required to evaluate reproducibility, oncologic safety, cost-effectiveness, and long-term outcomes.

International Journal of Oral and Maxillofacial Surgery
University of Catania (IT)
Openalex Percentile: Top 8%
Surgical Simulation and Training
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.