Technoeconomic and Environmental Assessment of a Power-to-H2-to-Power Metal Hydride System for a Renovated Greek Building

Abstract The present study examines the dynamic energy, environmental, and economic performance of a power-to- H 2 -to-power production and storage system based on metal-hydride (MH) technology, integrated as a hybrid energy storage solution for a renovated office building in Ptolemaida, Greece. The system utilizes nominal 10 kW p rooftop photovoltaics (PV), with a containerized unit comprising a 7 kW e proton exchange membrane (PEM) electrolyzer, a 3 kg hydrogen storage MH tank, and a 10 kW e PEM fuel cell. Eight alternative operational scenarios are examined for various PV capacities and MH storage sizes based on a parametric energy analysis. Annual dynamic energy simulations are performed using the INTEMA tool, a dynamic high-fidelity house-built process model applicable in building and energy systems, while the environmental and economic evaluation is conducted through the house-built life-cycle assessment/life-cycle costing tool, VERIFY, interoperable with INTEMA one, over a 50-year period. The findings illustrate that upsizing PV capacity increases energy autonomy, providing improvements of up to 40% compared to the baseline case, while MH storage size exhibits marginal benefits beyond the critical range of 4 to 5 kg. A multicriteria assessment has been utilized to optimize energy autonomy from the grid, life-cycle costs, and global warming potential. Under equal weighting of all criteria, the scenario with 120 kW p PV capacity and a 4 kg MH tank emerges as the optimal configuration, achieving the highest energy self-sufficiency by reducing imported grid electricity to approximately 67% and whole life cost by 24% compared to the baseline case, while maintaining a balanced environmental performance. The findings highlight the techno-economic viability of hydrogen-based storage systems in building-scale applications and provide practical insights for optimal system sizing under multiple sustainability objectives.

Authors

Institutions

Publication Details

Journal
Journal of Energy Engineering
Published
2026-09-01
DOI
https://doi.org/10.1061/jleed9.eyeng-7000
Primary Topic
Hybrid Renewable Energy Systems
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Technoeconomic and Environmental Assessment of a Power-to-H2-to-Power Metal Hydride System for a Renovated Greek Building

Nikolaos Margaritis, Stefano Barberis, Paraskevi Giourka, Nikolaos Ziozas et al.
Journal of Energy Engineering
Hybrid Renewable Energy Systems
article

Technoeconomic and Environmental Assessment of a Power-to-H2-to-Power Metal Hydride System for a Renovated Greek Building

Nikolaos Margaritis, Stefano Barberis, Paraskevi Giourka, Nikolaos Ziozas, Evangelos Bellos, Nikolaos Nikolopoulos, Ioannis-Athanasios Zornatzis, Oriol Galceran
article en

Abstract

Abstract The present study examines the dynamic energy, environmental, and economic performance of a power-to- H 2 -to-power production and storage system based on metal-hydride (MH) technology, integrated as a hybrid energy storage solution for a renovated office building in Ptolemaida, Greece. The system utilizes nominal 10 kW p rooftop photovoltaics (PV), with a containerized unit comprising a 7 kW e proton exchange membrane (PEM) electrolyzer, a 3 kg hydrogen storage MH tank, and a 10 kW e PEM fuel cell. Eight alternative operational scenarios are examined for various PV capacities and MH storage sizes based on a parametric energy analysis. Annual dynamic energy simulations are performed using the INTEMA tool, a dynamic high-fidelity house-built process model applicable in building and energy systems, while the environmental and economic evaluation is conducted through the house-built life-cycle assessment/life-cycle costing tool, VERIFY, interoperable with INTEMA one, over a 50-year period. The findings illustrate that upsizing PV capacity increases energy autonomy, providing improvements of up to 40% compared to the baseline case, while MH storage size exhibits marginal benefits beyond the critical range of 4 to 5 kg. A multicriteria assessment has been utilized to optimize energy autonomy from the grid, life-cycle costs, and global warming potential. Under equal weighting of all criteria, the scenario with 120 kW p PV capacity and a 4 kg MH tank emerges as the optimal configuration, achieving the highest energy self-sufficiency by reducing imported grid electricity to approximately 67% and whole life cost by 24% compared to the baseline case, while maintaining a balanced environmental performance. The findings highlight the techno-economic viability of hydrogen-based storage systems in building-scale applications and provide practical insights for optimal system sizing under multiple sustainability objectives.

Journal of Energy EngineeringVol. 152(6)
University of West Attica (GR), Universidad Cooperativa de Colombia (CO), University of Genoa (IT)
Responsible consumption and production
Openalex Percentile: Top 23%
Hybrid Renewable Energy Systems
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.