Patient-specific three-dimensional titanium plate versus conventional two-miniplate fixation for mandibular angle fractures: a randomized clinical trial

BACKGROUND: Mandibular angle fractures are clinically challenging because of their anatomical complexity and biomechanical loading. Conventional two-miniplate fixation requires intraoperative plate adaptation and transbuccal instrumentation. Patient-specific three-dimensional titanium plates are designed to conform to individual mandibular anatomy and may facilitate intraoperative fixation. This study aimed to clinically and radiographically evaluate patient-specific three-dimensional titanium plate versus conventional two mini-plate fixation in the management of mandibular angle fractures. METHODS: Sixteen patients with recent mandibular angle fractures were randomly allocated into two equal groups (n = 8). Group I underwent fixation using a patient-specific three-dimensional titanium plate positioned according to the preoperative virtual plan, whereas Group II received conventional two-miniplate fixation. The primary outcome was functional recovery assessed by maximal mouth opening (MMO). Secondary outcomes included intraoperative time, postoperative pain, facial edema, postoperative occlusion, wound healing, and CT bone density measurements in Hounsfield units (HU). Clinical outcomes were evaluated on postoperative days 1, 7, 14, and 30, whereas bone density was assessed immediately postoperatively and after 4 months. RESULTS: Intraoperative time was shorter in the patient-specific plate group than in the conventional two-miniplate group (40.00 ± 9.35 vs. 73.25 ± 11.22 min; P < 0.001). Postoperative pain was lower in the patient-specific plate group on postoperative day 1 (P = 0.015), while facial edema was lower on postoperative days 1 (P = 0.012) and 7 (P = 0.031). No statistically significant between-group differences were detected in maximal mouth opening, postoperative occlusion, Landry wound healing index scores, or CT bone density at the four-month follow-up. One patient in each group developed wound dehiscence, with complete healing after conservative management. CONCLUSIONS: Patient-specific three-dimensional titanium plate fixation was associated with shorter intraoperative time and lower early postoperative pain and edema. No statistically significant between-group differences were detected in the other assessed clinical and radiographic outcomes during the four-month follow-up. TRIAL REGISTRATION: The study was retrospectively registered at ClinicalTrials.gov (NCT07390734) on 29 January 2026.

Authors

Institutions

Publication Details

Journal
BMC Oral Health
Published
2026-11-16
DOI
https://doi.org/10.1186/s12903-026-10155-2
Primary Topic
Facial Trauma and Fracture Management
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Patient-specific three-dimensional titanium plate versus conventional two-miniplate fixation for mandibular angle fractures: a randomized clinical trial

Ragab S. Hassan, Mona Samy Oraby, Mostafa M. Eldibany, Asmaa M. Abd Elfattah
3 links
BMC Oral Health
Facial Trauma and Fracture Management
article

Patient-specific three-dimensional titanium plate versus conventional two-miniplate fixation for mandibular angle fractures: a randomized clinical trial

Ragab S. Hassan, Mona Samy Oraby, Mostafa M. Eldibany, Asmaa M. Abd Elfattah
article en

Abstract

BACKGROUND: Mandibular angle fractures are clinically challenging because of their anatomical complexity and biomechanical loading. Conventional two-miniplate fixation requires intraoperative plate adaptation and transbuccal instrumentation. Patient-specific three-dimensional titanium plates are designed to conform to individual mandibular anatomy and may facilitate intraoperative fixation. This study aimed to clinically and radiographically evaluate patient-specific three-dimensional titanium plate versus conventional two mini-plate fixation in the management of mandibular angle fractures. METHODS: Sixteen patients with recent mandibular angle fractures were randomly allocated into two equal groups (n = 8). Group I underwent fixation using a patient-specific three-dimensional titanium plate positioned according to the preoperative virtual plan, whereas Group II received conventional two-miniplate fixation. The primary outcome was functional recovery assessed by maximal mouth opening (MMO). Secondary outcomes included intraoperative time, postoperative pain, facial edema, postoperative occlusion, wound healing, and CT bone density measurements in Hounsfield units (HU). Clinical outcomes were evaluated on postoperative days 1, 7, 14, and 30, whereas bone density was assessed immediately postoperatively and after 4 months. RESULTS: Intraoperative time was shorter in the patient-specific plate group than in the conventional two-miniplate group (40.00 ± 9.35 vs. 73.25 ± 11.22 min; P < 0.001). Postoperative pain was lower in the patient-specific plate group on postoperative day 1 (P = 0.015), while facial edema was lower on postoperative days 1 (P = 0.012) and 7 (P = 0.031). No statistically significant between-group differences were detected in maximal mouth opening, postoperative occlusion, Landry wound healing index scores, or CT bone density at the four-month follow-up. One patient in each group developed wound dehiscence, with complete healing after conservative management. CONCLUSIONS: Patient-specific three-dimensional titanium plate fixation was associated with shorter intraoperative time and lower early postoperative pain and edema. No statistically significant between-group differences were detected in the other assessed clinical and radiographic outcomes during the four-month follow-up. TRIAL REGISTRATION: The study was retrospectively registered at ClinicalTrials.gov (NCT07390734) on 29 January 2026.

BMC Oral HealthVol. 26(1)
Alexandria University (EG)
Alexandria University
Good health and well-being
Facial Trauma and Fracture Management
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon