DEVELOPMENT AND VALIDATION OF A STABILITY-INDICATING UPLC METHOD FOR THE SIMULTANEOUS ESTIMATION OF OMBITASVIR, PARITAPREVIR AND RITONAVIR IN BULK AND PHARMACEUTICAL DOSAGE FORMS

A rapid, accurate, precise and stability-indicating UPLC method was developed and validated for the simultaneous estimation of Ombitasvir, Paritaprevir and Ritonavir in bulk drugs and pharmaceutical dosage forms. Chromatographic separation was achieved using a BEH C18 column with 0.01 N potassium dihydrogen phosphate buffer and acetonitrile (60:40, v/v). The method was validated according to ICH Q2(R2) guidelines and demonstrated excellent specificity, linearity, accuracy, precision, robustness and sensitivity. Forced degradation studies confirmed its stability-indicating capability. The developed method is suitable for routine quality control and stability testing of the combined pharmaceutical formulation.

Authors

Publication Details

Journal
Zenodo (CERN European Organization for Nuclear Research)
Published
2026-09-01
DOI
https://doi.org/10.5281/zenodo.22159136
Primary Topic
Analytical Methods in Pharmaceuticals
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

DEVELOPMENT AND VALIDATION OF A STABILITY-INDICATING UPLC METHOD FOR THE SIMULTANEOUS ESTIMATION OF OMBITASVIR, PARITAPREVIR AND RITONAVIR IN BULK AND PHARMACEUTICAL DOSAGE FORMS

Mr. Pranay Chennuri Dr. Rama Krishna Mungi*
Zenodo (CERN European Organization for Nuclear Research)
Analytical Methods in Pharmaceuticals
article

DEVELOPMENT AND VALIDATION OF A STABILITY-INDICATING UPLC METHOD FOR THE SIMULTANEOUS ESTIMATION OF OMBITASVIR, PARITAPREVIR AND RITONAVIR IN BULK AND PHARMACEUTICAL DOSAGE FORMS

Mr. Pranay Chennuri Dr. Rama Krishna Mungi*
article en

Abstract

A rapid, accurate, precise and stability-indicating UPLC method was developed and validated for the simultaneous estimation of Ombitasvir, Paritaprevir and Ritonavir in bulk drugs and pharmaceutical dosage forms. Chromatographic separation was achieved using a BEH C18 column with 0.01 N potassium dihydrogen phosphate buffer and acetonitrile (60:40, v/v). The method was validated according to ICH Q2(R2) guidelines and demonstrated excellent specificity, linearity, accuracy, precision, robustness and sensitivity. Forced degradation studies confirmed its stability-indicating capability. The developed method is suitable for routine quality control and stability testing of the combined pharmaceutical formulation.

Zenodo (CERN European Organization for Nuclear Research)
Openalex Percentile: Top 14%
Analytical Methods in Pharmaceuticals
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.