Composite Coating-driven Regulation of In Vivo Magnesium Degradation and Tissue Response

BACKGROUND/AIM: Magnesium-based alloys are promising materials for fabrication of bioresorbable medical devices. The application is limited by rapid degradation and associated adverse tissue responses. In this study, nanometer-thin composite polyelectrolyte/wax (PEM/W) coatings were fabricated on magnesium-based implant prototypes to delay their degradation. MATERIALS AND METHODS: Coatings were applied using a layer-by-layer technique. Cytocompatibility was assessed according to DIN ISO 10993-5 using NIH/3T3 fibroblasts and human umbilical vein endothelial cells (HUVECs). Degradation behavior was monitored by high-resolution micro-computed tomography (μ-CT), while tissue compatibility and host responses were evaluated histologically following DIN EN ISO 10993-6. RESULTS: evaluation using a rat subcutaneous implantation model demonstrated that the effectiveness of magnesium degradation modulation depends on the type of employed PEM. Micro-computed tomography analyses revealed that the hyaluronic acid/chitosan/wax coating provided the most robust protection over 60 days, exhibiting the lowest volume loss and superior preservation of implant geometry compared to the uncoated samples. Correspondingly, hydrogen-related gas cavity formation was reduced and temporally delayed in coated implants, indicating a more controlled degradation process. Histopathological analysis shows a moderate inflammatory response characteristic of biodegradable metallic implants, dominated by macrophages and lymphocytes. Importantly, coated implants were associated with reduced late-stage fibrosis and necrosis compared to uncoated magnesium. CONCLUSION: Overall, composite PEM/W coatings, especially those based on natural polyelectrolytes, represent a promising surface-engineering strategy for improving the safety and performance of resorbable magnesium implants.

Authors

Institutions

Publication Details

Journal
In Vivo
Published
2026-08-28
DOI
https://doi.org/10.21873/invivo.14421
Primary Topic
Magnesium Alloys: Properties and Applications
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Composite Coating-driven Regulation of In Vivo Magnesium Degradation and Tissue Response

Tonya Andreeva, S. Najman, Mike Barbeck, Sebastian Stammkötter et al.
In Vivo
Magnesium Alloys: Properties and Applications
article

Composite Coating-driven Regulation of In Vivo Magnesium Degradation and Tissue Response

Tonya Andreeva, S. Najman, Mike Barbeck, Sebastian Stammkötter, Rumen Krastev, O. Jung, Kim Burkhardt, F. Walther, SANJA STOJANOVIĆ
article en

Abstract

BACKGROUND/AIM: Magnesium-based alloys are promising materials for fabrication of bioresorbable medical devices. The application is limited by rapid degradation and associated adverse tissue responses. In this study, nanometer-thin composite polyelectrolyte/wax (PEM/W) coatings were fabricated on magnesium-based implant prototypes to delay their degradation. MATERIALS AND METHODS: Coatings were applied using a layer-by-layer technique. Cytocompatibility was assessed according to DIN ISO 10993-5 using NIH/3T3 fibroblasts and human umbilical vein endothelial cells (HUVECs). Degradation behavior was monitored by high-resolution micro-computed tomography (μ-CT), while tissue compatibility and host responses were evaluated histologically following DIN EN ISO 10993-6. RESULTS: evaluation using a rat subcutaneous implantation model demonstrated that the effectiveness of magnesium degradation modulation depends on the type of employed PEM. Micro-computed tomography analyses revealed that the hyaluronic acid/chitosan/wax coating provided the most robust protection over 60 days, exhibiting the lowest volume loss and superior preservation of implant geometry compared to the uncoated samples. Correspondingly, hydrogen-related gas cavity formation was reduced and temporally delayed in coated implants, indicating a more controlled degradation process. Histopathological analysis shows a moderate inflammatory response characteristic of biodegradable metallic implants, dominated by macrophages and lymphocytes. Importantly, coated implants were associated with reduced late-stage fibrosis and necrosis compared to uncoated magnesium. CONCLUSION: Overall, composite PEM/W coatings, especially those based on natural polyelectrolytes, represent a promising surface-engineering strategy for improving the safety and performance of resorbable magnesium implants.

In VivoVol. 40(5)
University of Nis (RS), TU Dortmund University (DE), Natural and Medical Sciences Institute (DE), University of Rostock (DE), Reutlingen University (DE), University of Tübingen (DE)
Deutsche Forschungsgemeinschaft
Openalex Percentile: Top 19%
Magnesium Alloys: Properties and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.