Real-time monitoring system of college students’ physical exercise physiological indexes based on deep learning and sensor data

The decline of college students’ physical health is a big problem. The development of wearable devices and deep learning technology provides a new path for sports physiological monitoring. In this study, a real-time monitoring system was built. Smart watches collected multimodal data such as heart rate, acceleration and skin conductance of 120 college students during exercise, and CNN-LSTM mixed model was used to classify fatigue and predict heart rate. The average absolute error of heart rate prediction on the test set is 3.2 times/min, the accuracy of fatigue classification is 88.3%, and the response time is 187 ms. There is a linear relationship between exercise intensity and heart rate (8.2 beats/min km/h), and the heart rate of overweight students is 5–8 beats/min higher. The system has been verified in physical education class, independent exercise and other scenes, and the early warning accuracy rate is 94.1%. Deep learning combined with sensor data can realize high-precision real-time physiological monitoring and provide quantitative tools for scientific exercise.

Authors

Institutions

Publication Details

Journal
Discover Applied Sciences
Published
2026-08-28
DOI
https://doi.org/10.1007/s42452-026-09477-1
Primary Topic
Advanced Technologies in Various Fields
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Real-time monitoring system of college students’ physical exercise physiological indexes based on deep learning and sensor data

Chengfeng Jiang
Discover Applied Sciences
Advanced Technologies in Various Fields
article

Real-time monitoring system of college students’ physical exercise physiological indexes based on deep learning and sensor data

Chengfeng Jiang
article en

Abstract

The decline of college students’ physical health is a big problem. The development of wearable devices and deep learning technology provides a new path for sports physiological monitoring. In this study, a real-time monitoring system was built. Smart watches collected multimodal data such as heart rate, acceleration and skin conductance of 120 college students during exercise, and CNN-LSTM mixed model was used to classify fatigue and predict heart rate. The average absolute error of heart rate prediction on the test set is 3.2 times/min, the accuracy of fatigue classification is 88.3%, and the response time is 187 ms. There is a linear relationship between exercise intensity and heart rate (8.2 beats/min km/h), and the heart rate of overweight students is 5–8 beats/min higher. The system has been verified in physical education class, independent exercise and other scenes, and the early warning accuracy rate is 94.1%. Deep learning combined with sensor data can realize high-precision real-time physiological monitoring and provide quantitative tools for scientific exercise.

Discover Applied Sciences
Zhengzhou University of Industrial Technology (CN)
Quality Education
Openalex Percentile: Top 8%
Advanced Technologies in Various Fields
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Real-time monitoring system of college students’ physical exercise physiological indexes based on deep learning and sensor data — Chengfeng Jiang · Discover Applied Sciences (2026) | TGRS Research Map | TGRS