Thigh abscess following alternate-site continuous glucose monitoring sensor placement

PURPOSE: To describe a methicillin-susceptible Staphylococcus aureus (MSSA) thigh abscess following alternate-site placement of a continuous glucose monitor (CGM) sensor and to highlight safety considerations associated with off-label device use in patients with poorly controlled diabetes. SUMMARY: A 49-year-old man with uncontrolled type 2 diabetes (glycated hemoglobin, 11.3%) was referred to an ambulatory care pharmacist for diabetes management. The patient placed the sensor on his upper thigh due to prior dislodgement from the upper arm. Three days later, the patient presented with a painful, erythematous, fluctuant 4.5 x 5 cm abscess at the sensor insertion site. Initial incision and drainage (I&D) was performed and oral sulfamethoxazole/trimethoprim was prescribed. Four days later, he returned with worsening pain and impaired ambulation requiring repeat I&D. Wound cultures grew MSSA. Management additionally included wound packing, topical mupirocin, and continuation of sulfamethoxazole/trimethoprim, with clinical improvement noted after the second I&D procedure. Cutaneous complications with CGM use are typically mild, infrequent, and most often involve contact or irritant dermatitis rather than infection. Reports of CGM-associated skin infections are rare, and none have been reported following sensor placement at unapproved insertion sites. CONCLUSION: This case underscores the potential for a skin and soft tissue infection following off-label CGM placement, especially in patients with uncontrolled hyperglycemia. Pharmacists play a critical role in reinforcing appropriate device use, identifying early signs of infection, and coordinating interdisciplinary care to mitigate device-related complications.

Authors

Institutions

Publication Details

Journal
American Journal of Health-System Pharmacy
Published
2026-08-28
DOI
https://doi.org/10.1093/ajhp/zxag252
Primary Topic
Hyperglycemia and glycemic control in critically ill and hospitalized patients
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Thigh abscess following alternate-site continuous glucose monitoring sensor placement

Kristy M. Shaeer, Raechel T. White, Jennifer Teeters, Kevin Cowart et al.
American Journal of Health-System Pharmacy
Hyperglycemia and glycemic control in critically ill and hospitalized patients
article

Thigh abscess following alternate-site continuous glucose monitoring sensor placement

Kristy M. Shaeer, Raechel T. White, Jennifer Teeters, Kevin Cowart, Tina L Pham, Benjamin Lord, Sarah Kimble, Erin L Reynolds
article en

Abstract

PURPOSE: To describe a methicillin-susceptible Staphylococcus aureus (MSSA) thigh abscess following alternate-site placement of a continuous glucose monitor (CGM) sensor and to highlight safety considerations associated with off-label device use in patients with poorly controlled diabetes. SUMMARY: A 49-year-old man with uncontrolled type 2 diabetes (glycated hemoglobin, 11.3%) was referred to an ambulatory care pharmacist for diabetes management. The patient placed the sensor on his upper thigh due to prior dislodgement from the upper arm. Three days later, the patient presented with a painful, erythematous, fluctuant 4.5 x 5 cm abscess at the sensor insertion site. Initial incision and drainage (I&D) was performed and oral sulfamethoxazole/trimethoprim was prescribed. Four days later, he returned with worsening pain and impaired ambulation requiring repeat I&D. Wound cultures grew MSSA. Management additionally included wound packing, topical mupirocin, and continuation of sulfamethoxazole/trimethoprim, with clinical improvement noted after the second I&D procedure. Cutaneous complications with CGM use are typically mild, infrequent, and most often involve contact or irritant dermatitis rather than infection. Reports of CGM-associated skin infections are rare, and none have been reported following sensor placement at unapproved insertion sites. CONCLUSION: This case underscores the potential for a skin and soft tissue infection following off-label CGM placement, especially in patients with uncontrolled hyperglycemia. Pharmacists play a critical role in reinforcing appropriate device use, identifying early signs of infection, and coordinating interdisciplinary care to mitigate device-related complications.

American Journal of Health-System Pharmacy
University of South Florida (US)
Good health and well-being
Openalex Percentile: Top 10%
Hyperglycemia and glycemic control in critically ill and hospitalized patients
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.