Hybrid-Enveloped Pedicle of Distant Abdominal Flap for Reconstruction of Extensive Upper Extremity Defects

BACKGROUND: Extensive upper extremity soft-tissue defects with exposed vital structures present a significant reconstructive challenge, particularly when microsurgical options are unavailable. Traditional distant pedicled abdominal flaps require a wide skin tube to protect the vascular pedicle, resulting in substantial donor-site morbidity and risks of pedicle compression. This study introduces a modified technique utilizing a hybrid combination of artificial dermis and local skin flap to create a hybrid-enveloped pedicle, aiming to minimize donor-site sacrifice and improve postoperative management. METHODS: Between 2019 and 2025, 5 patients with extensive proximal or mid-forearm defects underwent reconstruction using a paraumbilical perforator-based pedicled abdominal flap. The vascular pedicle was protected using a conduit constructed from a combination of a small skin flap and artificial dermis, forming a flexible tube. A retrospective review assessed flap survival, complications, donor-site outcomes, and functional recovery. RESULTS: All 5 flaps survived. The length of the pedicle segment enclosed by the hybrid envelope ranged from 4 to 7 cm. No pedicle compression, infection, or vascular crisis occurred. One patient developed distal flap-tip necrosis, which healed with conservative management. All flaps demonstrated satisfactory contour, texture, and integration with surrounding tissues. Upper-extremity joint motion recovered well in all cases, and all patients reported high satisfaction with the reconstructive outcome. CONCLUSIONS: The artificial dermis-assisted hybrid pedicle technique offers a safe, reliable, and tissue-sparing alternative to the conventional skin-tube method for distant abdominal flap transfer. It effectively reduces donor-site morbidity, minimizes compression risk, enhances postoperative monitoring, and facilitates earlier rehabilitation. This refined approach represents a practical and accessible reconstructive solution for complex upper extremity defects in settings where free tissue transfer is contraindicated or unavailable.

Authors

Institutions

Publication Details

Journal
Annals of Plastic Surgery
Published
2026-08-28
DOI
https://doi.org/10.1097/sap.0000000000004873
Primary Topic
Reconstructive Surgery and Microvascular Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Hybrid-Enveloped Pedicle of Distant Abdominal Flap for Reconstruction of Extensive Upper Extremity Defects

Dedi Tong, Z. Tang, Danying Wang, Lehao Wu et al.
Annals of Plastic Surgery
Reconstructive Surgery and Microvascular Techniques
article

Hybrid-Enveloped Pedicle of Distant Abdominal Flap for Reconstruction of Extensive Upper Extremity Defects

Dedi Tong, Z. Tang, Danying Wang, Lehao Wu, Yuanbo Liu, Yutong Yuan, Shan Zhu
article en

Abstract

BACKGROUND: Extensive upper extremity soft-tissue defects with exposed vital structures present a significant reconstructive challenge, particularly when microsurgical options are unavailable. Traditional distant pedicled abdominal flaps require a wide skin tube to protect the vascular pedicle, resulting in substantial donor-site morbidity and risks of pedicle compression. This study introduces a modified technique utilizing a hybrid combination of artificial dermis and local skin flap to create a hybrid-enveloped pedicle, aiming to minimize donor-site sacrifice and improve postoperative management. METHODS: Between 2019 and 2025, 5 patients with extensive proximal or mid-forearm defects underwent reconstruction using a paraumbilical perforator-based pedicled abdominal flap. The vascular pedicle was protected using a conduit constructed from a combination of a small skin flap and artificial dermis, forming a flexible tube. A retrospective review assessed flap survival, complications, donor-site outcomes, and functional recovery. RESULTS: All 5 flaps survived. The length of the pedicle segment enclosed by the hybrid envelope ranged from 4 to 7 cm. No pedicle compression, infection, or vascular crisis occurred. One patient developed distal flap-tip necrosis, which healed with conservative management. All flaps demonstrated satisfactory contour, texture, and integration with surrounding tissues. Upper-extremity joint motion recovered well in all cases, and all patients reported high satisfaction with the reconstructive outcome. CONCLUSIONS: The artificial dermis-assisted hybrid pedicle technique offers a safe, reliable, and tissue-sparing alternative to the conventional skin-tube method for distant abdominal flap transfer. It effectively reduces donor-site morbidity, minimizes compression risk, enhances postoperative monitoring, and facilitates earlier rehabilitation. This refined approach represents a practical and accessible reconstructive solution for complex upper extremity defects in settings where free tissue transfer is contraindicated or unavailable.

Annals of Plastic Surgery
Chinese Academy of Medical Sciences & Peking Union Medical College (CN), Peking University (CN), Peking Union Medical College Hospital (CN), Beijing Jishuitan Hospital (CN)
Openalex Percentile: Top 8%
Reconstructive Surgery and Microvascular Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.