Optimizing Computed Tomography-derived Surface Monitoring for Accurate Cancer Radiotherapy Setup

BACKGROUND/AIM: Surface-guided radiation therapy (SGRT) is being increasingly applied in cancer radiotherapy to support markerless setup, respiratory management, and intrafraction surface monitoring. When computed tomography (CT)-derived digital imaging and communications in medicine (DICOM) surfaces are imported into SGRT systems, the CT threshold used for external-contour generation may introduce systematic online delta values following image-guided setup correction. This phantom-based study investigated practical CT-threshold selection for accurate AlignRT-guided surface monitoring in cancer radiotherapy. MATERIALS AND METHODS: Two independent TrueBeam-AlignRT configurations were considered, one equipped with HD cameras and the other with Horizon cameras, using a cube phantom and an anthropomorphic thoracic phantom. External contours were generated for CT thresholds from -150 to -750 Hounsfield units (HU) in 100-HU increments. Following a cone-beam CT-based setup process and six-degree-of-freedom correction, DICOM surface selection was performed. AlignRT real-time delta values were recorded 2-5 s after surface selection. Additional technical analyses assessed the delta-value dependence on the treatment planning system, field-of-view/in-plane pixel size, and CT acquisition position under restricted conditions. RESULTS: Variation of the CT threshold had little apparent effect on the lateral and longitudinal delta values; however, the vertical delta values were more threshold-dependent. Lower thresholds, particularly of -550 to -750 HU, generally produced smaller vertical delta values. For the cube phantom and both system configurations, a -650-HU threshold yielded the smallest vertical delta value. For the thoracic phantom, comparable performance was observed for thresholds of -550, -650, and -750 HU; thus, a single universal optimum could not be defined. CONCLUSION: CT-threshold selection influences CT-derived DICOM surface generation for AlignRT-guided cancer radiotherapy, particularly in the vertical direction. A threshold of approximately -650 HU may be a practical starting point for similar workflows; however, institution-specific commissioning is required before clinical implementation.

Authors

Institutions

Publication Details

Journal
In Vivo
Published
2026-08-28
DOI
https://doi.org/10.21873/invivo.14432
Primary Topic
Advanced Radiotherapy Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Optimizing Computed Tomography-derived Surface Monitoring for Accurate Cancer Radiotherapy Setup

Kouta Hirotaki, Kenji Hotta, K. Kano, HAJIME OYOSHI
In Vivo
Advanced Radiotherapy Techniques
article

Optimizing Computed Tomography-derived Surface Monitoring for Accurate Cancer Radiotherapy Setup

Kouta Hirotaki, Kenji Hotta, K. Kano, HAJIME OYOSHI
article en

Abstract

BACKGROUND/AIM: Surface-guided radiation therapy (SGRT) is being increasingly applied in cancer radiotherapy to support markerless setup, respiratory management, and intrafraction surface monitoring. When computed tomography (CT)-derived digital imaging and communications in medicine (DICOM) surfaces are imported into SGRT systems, the CT threshold used for external-contour generation may introduce systematic online delta values following image-guided setup correction. This phantom-based study investigated practical CT-threshold selection for accurate AlignRT-guided surface monitoring in cancer radiotherapy. MATERIALS AND METHODS: Two independent TrueBeam-AlignRT configurations were considered, one equipped with HD cameras and the other with Horizon cameras, using a cube phantom and an anthropomorphic thoracic phantom. External contours were generated for CT thresholds from -150 to -750 Hounsfield units (HU) in 100-HU increments. Following a cone-beam CT-based setup process and six-degree-of-freedom correction, DICOM surface selection was performed. AlignRT real-time delta values were recorded 2-5 s after surface selection. Additional technical analyses assessed the delta-value dependence on the treatment planning system, field-of-view/in-plane pixel size, and CT acquisition position under restricted conditions. RESULTS: Variation of the CT threshold had little apparent effect on the lateral and longitudinal delta values; however, the vertical delta values were more threshold-dependent. Lower thresholds, particularly of -550 to -750 HU, generally produced smaller vertical delta values. For the cube phantom and both system configurations, a -650-HU threshold yielded the smallest vertical delta value. For the thoracic phantom, comparable performance was observed for thresholds of -550, -650, and -750 HU; thus, a single universal optimum could not be defined. CONCLUSION: CT-threshold selection influences CT-derived DICOM surface generation for AlignRT-guided cancer radiotherapy, particularly in the vertical direction. A threshold of approximately -650 HU may be a practical starting point for similar workflows; however, institution-specific commissioning is required before clinical implementation.

In VivoVol. 40(5)
Saitama Municipal Hospital (JP), National Hospital Organization (JP), National Cancer Center Hospital East (JP), Social Insurance Saitama Chuo Hospital (JP), National Hospital Organization Saitama Hospital
Peace, Justice and strong institutions
Openalex Percentile: Top 11%
Advanced Radiotherapy Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.