VELYS robotic-assisted solution achieves more accurate bone cutting and neutral ground mechanical axis compared with an accelerometer-based portable navigation system in ground kinematically aligned total knee arthroplasty

PURPOSE: robotic-assisted solution (VRAS) and that performed using an accelerometer-based portable navigation system (APNS) in patients with varus osteoarthritis. METHODS: This cohort study prospectively enrolled 35 consecutive patients who underwent ground KA-TKA using the VRAS and compared them with 35 consecutive patients treated with the same surgical procedure using the APNS. The primary end point was the accuracy of bone cutting and achievement of target alignment. Clinical outcomes were evaluated at 1 year postoperatively. RESULTS: The VRAS group demonstrated significantly smaller mean absolute errors from target values, particularly in femoral bone cutting and achievement of a neutral ground mechanical axis, compared with the APNS group (0.7 ± 0.8° versus 1.5 ± 1.1°, 1.6 ± 1.8% versus 3.0 ± 2.4%, p < 0.05, respectively). There were no significant differences in range of motion and 2011 Knee Society Score between groups. CONCLUSIONS: Ground KA-TKA performed using the VRAS achieved higher accuracy in bone cutting and more reliable achievement of a neutral ground mechanical axis, compared with the APNS.

Authors

Institutions

Publication Details

Journal
Knee Surgery and Related Research
Published
2026-08-28
DOI
https://doi.org/10.1186/s43019-026-00344-2
Primary Topic
Total Knee Arthroplasty Outcomes
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

VELYS robotic-assisted solution achieves more accurate bone cutting and neutral ground mechanical axis compared with an accelerometer-based portable navigation system in ground kinematically aligned total knee arthroplasty

Yuichi Kuroda, Tomoyuki Matsumoto, Ryosuke Kuroda, Masanori Tsubosaka et al.
Knee Surgery and Related Research
Total Knee Arthroplasty Outcomes
article

VELYS robotic-assisted solution achieves more accurate bone cutting and neutral ground mechanical axis compared with an accelerometer-based portable navigation system in ground kinematically aligned total knee arthroplasty

Yuichi Kuroda, Tomoyuki Matsumoto, Ryosuke Kuroda, Masanori Tsubosaka, Tomoyuki Kamenaga, Naoki Nakano, Shinya Hayashi
article en

Abstract

PURPOSE: robotic-assisted solution (VRAS) and that performed using an accelerometer-based portable navigation system (APNS) in patients with varus osteoarthritis. METHODS: This cohort study prospectively enrolled 35 consecutive patients who underwent ground KA-TKA using the VRAS and compared them with 35 consecutive patients treated with the same surgical procedure using the APNS. The primary end point was the accuracy of bone cutting and achievement of target alignment. Clinical outcomes were evaluated at 1 year postoperatively. RESULTS: The VRAS group demonstrated significantly smaller mean absolute errors from target values, particularly in femoral bone cutting and achievement of a neutral ground mechanical axis, compared with the APNS group (0.7 ± 0.8° versus 1.5 ± 1.1°, 1.6 ± 1.8% versus 3.0 ± 2.4%, p < 0.05, respectively). There were no significant differences in range of motion and 2011 Knee Society Score between groups. CONCLUSIONS: Ground KA-TKA performed using the VRAS achieved higher accuracy in bone cutting and more reliable achievement of a neutral ground mechanical axis, compared with the APNS.

Knee Surgery and Related ResearchVol. 38(1)
Kobe University (JP)
Johnson and Johnson KK
Openalex Percentile: Top 8%
Total Knee Arthroplasty Outcomes
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

VELYS robotic-assisted solution achieves more accurate bone cutting and neutral ground mechanical axis compared with an accelerometer-based portable navigation system in ground kinematically aligned total knee arthroplasty — Yuichi Kuroda, Tomoyuki Matsumoto, et al. · Knee Surgery and Related Research (2026) | TGRS Research Map | TGRS