A novel digital strategy to support leakage detection in WDNs

Background Real water losses are among the most critical challenges in managing urban water distribution networks (WDN). They represent a key indicator of the system’s overall “health”, depending on asset deterioration and pressure control. Reducing water losses carries important socio-economic and environmental consequences, affecting the sustainability, reliability, and affordability of water supply systems. Digital transformation offers unprecedented opportunity to reach these goals by reviewing technical decision processes and exploiting new tools and technologies.Methods In the context of water losses management in WDN, a digital strategy has been recently introduced to support various asset management tasks, including model construction (i.e. geometric model, model calibration), engineering of network monitoring (design of district metering areas design – DMA) and control, up to planning actions (pipe replacement, isolation valve systems). This work presents a novel two-phase model-based strategy for leakage detection in WDN cast into a structured digital water strategy for asset management based on the paradigm of digital water services. The first phase identifies the DMA affected by a punctual leakage, exploiting the novel asset management support indicator (AMSI); the second phase pre-localises the leaking pipe within that DMA, based on anomalies in pressure observations.Results The methodology is demonstrated on a real case WDN. The leakage detection strategy identifies a sequence of pipes to inspect analysing the pressure variations with respect to the normal operating condition. Different examples of pipe classification are reported.Conclusion The new leakage detection strategy is consistent with the digital water strategy, supporting the asset management task with specific tool. Moreover, field-data and information can be progressively integrated to refine the inspection sequence, enhancing leakage detection over time.

Authors

Institutions

Publication Details

Journal
Digital Water
Published
2026-08-28
DOI
https://doi.org/10.1080/28375807.2026.2724269
Primary Topic
Water Systems and Optimization
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A novel digital strategy to support leakage detection in WDNs

Simona Corrado, Daniele Laucelli, Luigi Berardi, Simone Ripani et al.
Digital Water
Water Systems and Optimization
article

A novel digital strategy to support leakage detection in WDNs

Simona Corrado, Daniele Laucelli, Luigi Berardi, Simone Ripani, Giuseppina Messa, Giulia Acconciaioco
article en

Abstract

Background Real water losses are among the most critical challenges in managing urban water distribution networks (WDN). They represent a key indicator of the system’s overall “health”, depending on asset deterioration and pressure control. Reducing water losses carries important socio-economic and environmental consequences, affecting the sustainability, reliability, and affordability of water supply systems. Digital transformation offers unprecedented opportunity to reach these goals by reviewing technical decision processes and exploiting new tools and technologies.Methods In the context of water losses management in WDN, a digital strategy has been recently introduced to support various asset management tasks, including model construction (i.e. geometric model, model calibration), engineering of network monitoring (design of district metering areas design – DMA) and control, up to planning actions (pipe replacement, isolation valve systems). This work presents a novel two-phase model-based strategy for leakage detection in WDN cast into a structured digital water strategy for asset management based on the paradigm of digital water services. The first phase identifies the DMA affected by a punctual leakage, exploiting the novel asset management support indicator (AMSI); the second phase pre-localises the leaking pipe within that DMA, based on anomalies in pressure observations.Results The methodology is demonstrated on a real case WDN. The leakage detection strategy identifies a sequence of pipes to inspect analysing the pressure variations with respect to the normal operating condition. Different examples of pipe classification are reported.Conclusion The new leakage detection strategy is consistent with the digital water strategy, supporting the asset management task with specific tool. Moreover, field-data and information can be progressively integrated to refine the inspection sequence, enhancing leakage detection over time.

Digital WaterVol. 4(1)
University of Chieti-Pescara (IT), Institut d'Economie Scientifique Et de Gestion (FR), Polytechnic University of Bari (IT)
Openalex Percentile: Top 16%
Water Systems and Optimization
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.