Evaluating the Construct and Face Validity of the Eyesi Slit Lamp Simulator

Background: Simulation-based training has emerged as a valuable tool in ophthalmology education, offering a risk free and structured environment in which trainees can develop clinical skills prior to direct patient care; however, rigorous validation is essential to ensure its educational utility and effectiveness. Purpose: To assess the construct and face validity of the Eyesi Slit Lamp simulator’s optic nerve and gonioscopy modules. Methods: Medical students, ophthalmology residents, and attendings were recruited for this prospective study at NYU Langone Health using a consecutive sampling approach. To assess construct validity, participants completed optic nerve and gonioscopy modules on the Eyesi Slit Lamp simulator. Time to completion and examination scores were recorded. Performance between medical students and the combined group of residents and attendings was compared using the Wilcoxon rank-sum test. Face validity was assessed through participant surveys. Results: Thirty participants (14 medical students, 13 residents, and 3 ophthalmology attendings) were enrolled. Medical students had a lower task completion rate and significantly longer time to completion than residents and attendings for both the optic nerve (p = 0.036) and gonioscopy (p < 0.001) modules. The optic nerve module and gonioscopy were rated as somewhat realistic, with a median score of 4 by residents and 3.5 by attendings (on a scale of 1-5, where 1 is considered very unrealistic, and 5 is considered very realistic). Conclusions: The EyeSi Slit Lamp simulator’s optic nerve and gonioscopy modules demonstrated construct validity, because it effectively differentiated performance between training levels. Although there was no strong evidence for face validity, participants nevertheless highly recommended the simulator for trainee education.

Authors

Institutions

Publication Details

Journal
Journal of Academic Ophthalmology
Published
2026-08-27
DOI
https://doi.org/10.62199/2475-4757.1351
Primary Topic
Ophthalmology and Visual Health Research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Evaluating the Construct and Face Validity of the Eyesi Slit Lamp Simulator

Alexi Geevarghese, Jiyuan Hu, Christina R. Prescott, Jacob Wong et al.
Journal of Academic Ophthalmology
Ophthalmology and Visual Health Research
article

Evaluating the Construct and Face Validity of the Eyesi Slit Lamp Simulator

Alexi Geevarghese, Jiyuan Hu, Christina R. Prescott, Jacob Wong, Andrea Blitzer
article en

Abstract

Background: Simulation-based training has emerged as a valuable tool in ophthalmology education, offering a risk free and structured environment in which trainees can develop clinical skills prior to direct patient care; however, rigorous validation is essential to ensure its educational utility and effectiveness. Purpose: To assess the construct and face validity of the Eyesi Slit Lamp simulator’s optic nerve and gonioscopy modules. Methods: Medical students, ophthalmology residents, and attendings were recruited for this prospective study at NYU Langone Health using a consecutive sampling approach. To assess construct validity, participants completed optic nerve and gonioscopy modules on the Eyesi Slit Lamp simulator. Time to completion and examination scores were recorded. Performance between medical students and the combined group of residents and attendings was compared using the Wilcoxon rank-sum test. Face validity was assessed through participant surveys. Results: Thirty participants (14 medical students, 13 residents, and 3 ophthalmology attendings) were enrolled. Medical students had a lower task completion rate and significantly longer time to completion than residents and attendings for both the optic nerve (p = 0.036) and gonioscopy (p < 0.001) modules. The optic nerve module and gonioscopy were rated as somewhat realistic, with a median score of 4 by residents and 3.5 by attendings (on a scale of 1-5, where 1 is considered very unrealistic, and 5 is considered very realistic). Conclusions: The EyeSi Slit Lamp simulator’s optic nerve and gonioscopy modules demonstrated construct validity, because it effectively differentiated performance between training levels. Although there was no strong evidence for face validity, participants nevertheless highly recommended the simulator for trainee education.

Journal of Academic OphthalmologyVol. 18(2)
New York University (US)
Quality Education
Openalex Percentile: Top 8%
Ophthalmology and Visual Health Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Evaluating the Construct and Face Validity of the Eyesi Slit Lamp Simulator — Alexi Geevarghese, Jiyuan Hu, et al. · Journal of Academic Ophthalmology (2026) | TGRS Research Map | TGRS