CT-guided Preoperative Localization of Impalpable Pulmonary Nodules: Comparison Between Two Devices

Background/Aim: To compare two different devices for computed tomography (CT)-guided preoperative localization of impalpable pulmonary nodules in terms of effectiveness, technical and clinical success and complications rate. Patients and Methods: CT-guided preoperative localization procedures of small or ground glass (i.e., impalpable) pulmonary nodules performed in our center from April 2018 to December 2021 before lung resection with video-assisted thoracic surgery (VATS) were retrospectively analyzed. Two different markers were used: spiral-wire (SpW) and hydrogel plug (HyP). For each nodule the density, size and pleural distance were evaluated. Technical (correct CT-guided positioning of the marker) and clinical (its correct localization in VATS) success were assessed for each device. Complications as displacement, pneumothorax and parenchymal hemorrhage (PH) were registered. Statistical analysis was made by Chi-square, Wilcoxon and Fisher tests. Results: Eighty-five consecutive patients (46/39 males/female; mean age 42 years, range=4-80 years) with 85 pulmonary nodules (maximum diameter: 8.5±6.4 mm in the SpW group and 17.0±4.2 mm in the HyP group) underwent preoperative CT-guided localization with SpW (65/85, 76.5%) or HyP (20/85, 23.5%) device. Correct CT-guided landmark positioning was obtained in 100% of cases. VATS revealed 4/65 (6.2%) cases of marker displacement in the SpW group and 3/17 (17.6%) cases in the HyP group (p=0.0353). Pneumothorax occurred in 40/65 (61.5%) cases in the SpW group and in 11/20 (55.0%) cases in the HyP group (p=0.602); no drainage tube was needed. PH occurred in 34/65 (52.3%) cases in SpW group and in 14/20 (70.0%) cases in HyP group (p=0.0163). Conclusion: Both markers are effective for the preoperative localization of impalpable pulmonary nodules in VATS. SpW seems to be slightly more stable and safer than HyP lung marker in relation to the displacement and PH rate.

Authors

Institutions

Publication Details

Journal
In Vivo
Published
2026-08-28
DOI
https://doi.org/10.21873/invivo.14438
Primary Topic
Lung Cancer Diagnosis and Treatment
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

CT-guided Preoperative Localization of Impalpable Pulmonary Nodules: Comparison Between Two Devices

Elisabetta Balestro, Chiara Giraudo, Fiorella Calabrese, Giulio Barbiero et al.
In Vivo
Lung Cancer Diagnosis and Treatment
article

CT-guided Preoperative Localization of Impalpable Pulmonary Nodules: Comparison Between Two Devices

Elisabetta Balestro, Chiara Giraudo, Fiorella Calabrese, Giulio Barbiero, Michele Battistel, Stefano Groff, MARCO MAMMANA, ANDREA DELL’AMORE
article en

Abstract

Background/Aim: To compare two different devices for computed tomography (CT)-guided preoperative localization of impalpable pulmonary nodules in terms of effectiveness, technical and clinical success and complications rate. Patients and Methods: CT-guided preoperative localization procedures of small or ground glass (i.e., impalpable) pulmonary nodules performed in our center from April 2018 to December 2021 before lung resection with video-assisted thoracic surgery (VATS) were retrospectively analyzed. Two different markers were used: spiral-wire (SpW) and hydrogel plug (HyP). For each nodule the density, size and pleural distance were evaluated. Technical (correct CT-guided positioning of the marker) and clinical (its correct localization in VATS) success were assessed for each device. Complications as displacement, pneumothorax and parenchymal hemorrhage (PH) were registered. Statistical analysis was made by Chi-square, Wilcoxon and Fisher tests. Results: Eighty-five consecutive patients (46/39 males/female; mean age 42 years, range=4-80 years) with 85 pulmonary nodules (maximum diameter: 8.5±6.4 mm in the SpW group and 17.0±4.2 mm in the HyP group) underwent preoperative CT-guided localization with SpW (65/85, 76.5%) or HyP (20/85, 23.5%) device. Correct CT-guided landmark positioning was obtained in 100% of cases. VATS revealed 4/65 (6.2%) cases of marker displacement in the SpW group and 3/17 (17.6%) cases in the HyP group (p=0.0353). Pneumothorax occurred in 40/65 (61.5%) cases in the SpW group and in 11/20 (55.0%) cases in the HyP group (p=0.602); no drainage tube was needed. PH occurred in 34/65 (52.3%) cases in SpW group and in 14/20 (70.0%) cases in HyP group (p=0.0163). Conclusion: Both markers are effective for the preoperative localization of impalpable pulmonary nodules in VATS. SpW seems to be slightly more stable and safer than HyP lung marker in relation to the displacement and PH rate.

In VivoVol. 40(5)
University of Padua (IT)
Good health and well-being
Openalex Percentile: Top 11%
Lung Cancer Diagnosis and Treatment
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.