High-sensitivity Cardiac Troponin I Changes Following Subcutaneous Needle Puncture, Restraint, and Venipuncture in Cynomolgus Monkeys

BACKGROUND/AIM: Cardiac troponin I (cTnI) is a sensitive biomarker of myocardial injury in which procedure-related stress may cause mild, non-injury-related increases. This study aimed to characterize procedure-related variability of high-sensitivity cTnI and related biomarkers in cynomolgus monkeys and to compare a single molecule counting (SMC) assay with an enzyme-linked immunosorbent assay (ELISA). MATERIALS AND METHODS: Five male cynomolgus monkeys received subcutaneous physiological saline (2 ml/kg). Blood was collected under restraint at 0 (baseline), 0.5, 1, 2, 4, 8, and 24 h. cTnI was measured by SMC [lower limit of quantification (LLOQ): 0.7 pg/ml] and ELISA (LLOQ: 156 pg/ml). Cardiac troponin T, creatine kinase (CK), lactate dehydrogenase (LDH), and their isoenzymes (CK-MM, CK-MB, LDH1, LDH2, LDH4, LDH5), aspartate aminotransferase (AST), heart-type fatty acid-binding protein (H-FABP), and myoglobin were measured. Post-procedure values were compared with the baseline. RESULTS: With SMC, cTnI was below the LLOQ at baseline in all animals, increased significantly at 2 and 4 h (peak at 4 h: mean approximately 16 pg/ml), and returned to near baseline by 24 h. With ELISA, baseline cTnI was below the LLOQ in four of five animals. Many post-procedure values were also below the LLOQ, although cTnI increased at 2 and 4 h (peak at 4 h). The cTnI quantification rate was higher with SMC (83%) than with ELISA (54%). cTnT, H-FABP, and myoglobin increased transiently and returned to baseline by 24 h, whereas CK and LDH and their isoenzymes and AST increased but remained above baseline at 24 h. CONCLUSION: Subcutaneous needle puncture, restraint, and venipuncture can produce slight, transient increases in high-sensitivity cTnI. The SMC assay detected low-level variability better than ELISA, supporting stress-aware interpretation with baseline adjustment and control comparisons.

Authors

Institutions

Publication Details

Journal
In Vivo
Published
2026-08-28
DOI
https://doi.org/10.21873/invivo.14425
Primary Topic
Cardiac, Anesthesia and Surgical Outcomes
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

High-sensitivity Cardiac Troponin I Changes Following Subcutaneous Needle Puncture, Restraint, and Venipuncture in Cynomolgus Monkeys

Teppei Iwakiri, Tomonobu Yamada, Y. Taniguchi, HIROAKI KAWAGUCHI et al.
In Vivo
Cardiac, Anesthesia and Surgical Outcomes
article

High-sensitivity Cardiac Troponin I Changes Following Subcutaneous Needle Puncture, Restraint, and Venipuncture in Cynomolgus Monkeys

Teppei Iwakiri, Tomonobu Yamada, Y. Taniguchi, HIROAKI KAWAGUCHI, TETSUYA YOSHIKAWA
article en

Abstract

BACKGROUND/AIM: Cardiac troponin I (cTnI) is a sensitive biomarker of myocardial injury in which procedure-related stress may cause mild, non-injury-related increases. This study aimed to characterize procedure-related variability of high-sensitivity cTnI and related biomarkers in cynomolgus monkeys and to compare a single molecule counting (SMC) assay with an enzyme-linked immunosorbent assay (ELISA). MATERIALS AND METHODS: Five male cynomolgus monkeys received subcutaneous physiological saline (2 ml/kg). Blood was collected under restraint at 0 (baseline), 0.5, 1, 2, 4, 8, and 24 h. cTnI was measured by SMC [lower limit of quantification (LLOQ): 0.7 pg/ml] and ELISA (LLOQ: 156 pg/ml). Cardiac troponin T, creatine kinase (CK), lactate dehydrogenase (LDH), and their isoenzymes (CK-MM, CK-MB, LDH1, LDH2, LDH4, LDH5), aspartate aminotransferase (AST), heart-type fatty acid-binding protein (H-FABP), and myoglobin were measured. Post-procedure values were compared with the baseline. RESULTS: With SMC, cTnI was below the LLOQ at baseline in all animals, increased significantly at 2 and 4 h (peak at 4 h: mean approximately 16 pg/ml), and returned to near baseline by 24 h. With ELISA, baseline cTnI was below the LLOQ in four of five animals. Many post-procedure values were also below the LLOQ, although cTnI increased at 2 and 4 h (peak at 4 h). The cTnI quantification rate was higher with SMC (83%) than with ELISA (54%). cTnT, H-FABP, and myoglobin increased transiently and returned to baseline by 24 h, whereas CK and LDH and their isoenzymes and AST increased but remained above baseline at 24 h. CONCLUSION: Subcutaneous needle puncture, restraint, and venipuncture can produce slight, transient increases in high-sensitivity cTnI. The SMC assay detected low-level variability better than ELISA, supporting stress-aware interpretation with baseline adjustment and control comparisons.

In VivoVol. 40(5)
Shin Nippon Biomedical Laboratories (Japan) (JP), Kitasato University (JP)
Good health and well-being
Openalex Percentile: Top 10%
Cardiac, Anesthesia and Surgical Outcomes
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.