Evaluating the Cost-Effectiveness of Interlinked Fire Alarm Systems in Scotland and England

Abstract This paper applies the J value framework to assess when interlinked domestic fire alarm systems would be cost effective in Scotland and England. Pre policy national statistics pool dwellings with no alarms, standalone alarms (the vast majority), and some interlinked systems, so they do not identify the marginal effect of interlinking. We therefore present threshold (break-even) conditions: combinations of reductions in fatalities, injuries, and direct property damage that yield J ≤ 1 for self and professional installation, using historical statistics only as non-causal, illustrative anchors for sensitivity analyses. It was found that, across both countries, damage reduction is the dominant driver of cost-effectiveness, followed by fatality reduction; injury reduction has limited influence (assuming direct injury costs only). One-way thresholds indicate that achieving $$\:J\le\:1$$ typically requires around 30–60% reduction in direct property damage, with fatality thresholds generally around 40–80% depending on installation method and region. Two-factor (damage and fatality) thresholds show trade-offs between these reductions, with more demanding conditions in England due to higher expected damage per fire. Tornado analyses centred on an illustrative base case confirm that installation cost and damage-related inputs exert the greatest influence on $$\:J$$ , while societal discount rates have modest effects. Interlinked systems can be cost effective where installed costs are lower (for example self-installation) and reductions in property damage, and secondarily fatalities, are moderate to large. Improved data on alarm type and performance, property-damage costs, and near-misses would enable movement from threshold analysis to causal evaluation.

Authors

Institutions

Publication Details

Journal
Fire Technology
Published
2026-08-28
DOI
https://doi.org/10.1007/s10694-026-01991-3
Primary Topic
Injury Epidemiology and Prevention
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Evaluating the Cost-Effectiveness of Interlinked Fire Alarm Systems in Scotland and England

David Rush, Samiksha Bastola
Fire Technology
Injury Epidemiology and Prevention
article

Evaluating the Cost-Effectiveness of Interlinked Fire Alarm Systems in Scotland and England

David Rush, Samiksha Bastola
article en

Abstract

Abstract This paper applies the J value framework to assess when interlinked domestic fire alarm systems would be cost effective in Scotland and England. Pre policy national statistics pool dwellings with no alarms, standalone alarms (the vast majority), and some interlinked systems, so they do not identify the marginal effect of interlinking. We therefore present threshold (break-even) conditions: combinations of reductions in fatalities, injuries, and direct property damage that yield J ≤ 1 for self and professional installation, using historical statistics only as non-causal, illustrative anchors for sensitivity analyses. It was found that, across both countries, damage reduction is the dominant driver of cost-effectiveness, followed by fatality reduction; injury reduction has limited influence (assuming direct injury costs only). One-way thresholds indicate that achieving $$\:J\le\:1$$ typically requires around 30–60% reduction in direct property damage, with fatality thresholds generally around 40–80% depending on installation method and region. Two-factor (damage and fatality) thresholds show trade-offs between these reductions, with more demanding conditions in England due to higher expected damage per fire. Tornado analyses centred on an illustrative base case confirm that installation cost and damage-related inputs exert the greatest influence on $$\:J$$ , while societal discount rates have modest effects. Interlinked systems can be cost effective where installed costs are lower (for example self-installation) and reductions in property damage, and secondarily fatalities, are moderate to large. Improved data on alarm type and performance, property-damage costs, and near-misses would enable movement from threshold analysis to causal evaluation.

Fire TechnologyVol. 62(6)
University of Edinburgh (GB)
Openalex Percentile: Top 8%
Injury Epidemiology and Prevention
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Evaluating the Cost-Effectiveness of Interlinked Fire Alarm Systems in Scotland and England — David Rush, Samiksha Bastola · Fire Technology (2026) | TGRS Research Map | TGRS