ACPSEM guideline: recommendations for a fluoroscopic system quality assurance program

Fluoroscopic systems are increasingly used for complex image-guided procedures across medical disciplines in Australia and New Zealand. The associated radiation exposure risks to patients and staff necessitate robust quality assurance (QA) programs. However, no national guidance has previously existed for a standardised fluoroscopy QA program in the Australia and New Zealand context. To provide evidence-informed recommendations for the quality assurance of fluoroscopic systems in Australia and New Zealand, addressing the absence of national standards and supporting consistent, high-quality clinical practice. This guideline was developed by the ACPSEM Fluoroscopy QA Working Group, established in February 2019 by the ACPSEM Radiology Specialty Group. Recommendations were informed by an expert-driven review of international standards and protocols, including those from the AAPM, IAEA, EFOMP, and IEC, adapted for Australia and New Zealand practice through working-group discussions and reviews. The draft guideline underwent stakeholder consultation, including circulation to ACPSEM members and relevant professional organisations. The guideline outlines recommended QA tests for medical physicists at acceptance, commissioning, and periodic intervals, along with routine quality control procedures for radiographers. Key areas include radiation dose output assessment, automatic dose rate control verification, image quality evaluation, personal protective equipment integrity testing, and clinical dose audits. A quality review meeting framework is also provided. This guideline establishes a nationally consistent framework for fluoroscopy QA that complements local regulatory requirements. Its adoption will support patient safety, staff radiation protection, and optimal equipment performance across healthcare facilities in Australia and New Zealand.

Authors

Institutions

Publication Details

Journal
Physical and Engineering Sciences in Medicine
Published
2026-08-27
DOI
https://doi.org/10.1007/s13246-026-01796-2
Primary Topic
Radiation Dose and Imaging
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

ACPSEM guideline: recommendations for a fluoroscopic system quality assurance program

Kam L. Lee, Amanda Perdomo, Giles Wynn-Williams, Zoe Brady et al.
Physical and Engineering Sciences in Medicine
Radiation Dose and Imaging
article

ACPSEM guideline: recommendations for a fluoroscopic system quality assurance program

Kam L. Lee, Amanda Perdomo, Giles Wynn-Williams, Zoe Brady, Mohamed Khaldoun Badawy, Benjamin Keir, Peter Barnes
article en

Abstract

Fluoroscopic systems are increasingly used for complex image-guided procedures across medical disciplines in Australia and New Zealand. The associated radiation exposure risks to patients and staff necessitate robust quality assurance (QA) programs. However, no national guidance has previously existed for a standardised fluoroscopy QA program in the Australia and New Zealand context. To provide evidence-informed recommendations for the quality assurance of fluoroscopic systems in Australia and New Zealand, addressing the absence of national standards and supporting consistent, high-quality clinical practice. This guideline was developed by the ACPSEM Fluoroscopy QA Working Group, established in February 2019 by the ACPSEM Radiology Specialty Group. Recommendations were informed by an expert-driven review of international standards and protocols, including those from the AAPM, IAEA, EFOMP, and IEC, adapted for Australia and New Zealand practice through working-group discussions and reviews. The draft guideline underwent stakeholder consultation, including circulation to ACPSEM members and relevant professional organisations. The guideline outlines recommended QA tests for medical physicists at acceptance, commissioning, and periodic intervals, along with routine quality control procedures for radiographers. Key areas include radiation dose output assessment, automatic dose rate control verification, image quality evaluation, personal protective equipment integrity testing, and clinical dose audits. A quality review meeting framework is also provided. This guideline establishes a nationally consistent framework for fluoroscopy QA that complements local regulatory requirements. Its adoption will support patient safety, staff radiation protection, and optimal equipment performance across healthcare facilities in Australia and New Zealand.

Physical and Engineering Sciences in Medicine
Royal Children's Hospital (AU), The University of Melbourne (AU), Royal Brisbane and Women's Hospital (AU), Monash Medical Centre (AU), Dunedin Public Hospital (NZ), Monash Health (AU), Environmental Protection Agency (IE), Alfred Health (AU), Austin Health (AU), Monash University (AU)
Partnerships for the goals
Openalex Percentile: Top 11%
Radiation Dose and Imaging
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies