Stand‐alone graph‐based lung airway labeling with quantitative validations

BACKGROUND: Previous studies have shown that protecting airways connected to high-functioning lung parenchyma reduces the risk of post-treatment radiation-induced lung injury. To account for airway sparing in radiotherapy planning, a critical requirement is to characterize the geometry and radiation response of individual airway segments. PURPOSE: To report on automated individual airway labeling framework with branch dimensions extracted from CT-derived virtual bronchoscopy images. METHODS: We developed an automated graph-based topological labeling algorithm with bifurcation detections and context-based denoising. In-house modules for estimating airway diameters and tube length were also developed. Both labeling and meta-information estimation were validated against a commercial virtual bronchoscopy software in data from 20 lung cancer patients. Labeling metrics were segmentation surface scores: i.e., average symmetric surface distance (ASSD), normalized surface distance (NSD), and 95th percentile surface Hausdorff (HD95surf). Meta-information metrics were absolute errors of branch major diameter, minor diameter, and tube length. Mean absolute error (MAE) and root mean square error (RMSE) were calculated to assess meta-information deviations in both validations. RESULTS: Mean and standard deviations were 0.56 ± 0.21 mm for ASSD, 87.66 ± 3.20% for NSD, and 2.51 ± 0.68 mm for HD95surf. Deviations of meta-information metrics in labeling validation were MAE/RMSE: 0.33 ± 0.09/0.67 ± 0.16 mm for major diameter, 0.24 ± 0.07/0.53 ± 0.15 mm for minor diameter, and 3.27 ± 0.82/5.53 ± 1.53 mm for tube length. Deviations of meta-information metrics in meta-information validation were MAE/RMSE: 1.81 ± 0.30/2.31 ± 0.41 mm for major diameter, 1.25 ± 0.27/1.14 ± 0.26 mm for minor diameter, and 2.20 ± 0.32/3.24 ± 0.49 mm for tube length. CONCLUSION: The proposed open-source framework provides stand-alone, fully-automated airway labeling with very good agreement with a commercial virtual bronchoscopy system. Our method shows strong potential for use in functionally-guided lung sparing in radiation treatment plan optimization.

Authors

Institutions

Publication Details

Journal
Medical Physics
Published
2026-08-27
DOI
https://doi.org/10.1002/mp.70634
Primary Topic
Advanced Radiotherapy Techniques
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Stand‐alone graph‐based lung airway labeling with quantitative validations

Arezoo Modiri, Hairong Chen, Amit Sawant
Medical Physics
Advanced Radiotherapy Techniques
article

Stand‐alone graph‐based lung airway labeling with quantitative validations

Arezoo Modiri, Hairong Chen, Amit Sawant
article en

Abstract

BACKGROUND: Previous studies have shown that protecting airways connected to high-functioning lung parenchyma reduces the risk of post-treatment radiation-induced lung injury. To account for airway sparing in radiotherapy planning, a critical requirement is to characterize the geometry and radiation response of individual airway segments. PURPOSE: To report on automated individual airway labeling framework with branch dimensions extracted from CT-derived virtual bronchoscopy images. METHODS: We developed an automated graph-based topological labeling algorithm with bifurcation detections and context-based denoising. In-house modules for estimating airway diameters and tube length were also developed. Both labeling and meta-information estimation were validated against a commercial virtual bronchoscopy software in data from 20 lung cancer patients. Labeling metrics were segmentation surface scores: i.e., average symmetric surface distance (ASSD), normalized surface distance (NSD), and 95th percentile surface Hausdorff (HD95surf). Meta-information metrics were absolute errors of branch major diameter, minor diameter, and tube length. Mean absolute error (MAE) and root mean square error (RMSE) were calculated to assess meta-information deviations in both validations. RESULTS: Mean and standard deviations were 0.56 ± 0.21 mm for ASSD, 87.66 ± 3.20% for NSD, and 2.51 ± 0.68 mm for HD95surf. Deviations of meta-information metrics in labeling validation were MAE/RMSE: 0.33 ± 0.09/0.67 ± 0.16 mm for major diameter, 0.24 ± 0.07/0.53 ± 0.15 mm for minor diameter, and 3.27 ± 0.82/5.53 ± 1.53 mm for tube length. Deviations of meta-information metrics in meta-information validation were MAE/RMSE: 1.81 ± 0.30/2.31 ± 0.41 mm for major diameter, 1.25 ± 0.27/1.14 ± 0.26 mm for minor diameter, and 2.20 ± 0.32/3.24 ± 0.49 mm for tube length. CONCLUSION: The proposed open-source framework provides stand-alone, fully-automated airway labeling with very good agreement with a commercial virtual bronchoscopy system. Our method shows strong potential for use in functionally-guided lung sparing in radiation treatment plan optimization.

Medical PhysicsVol. 53(9)
University of Maryland, Baltimore (US)
National Institutes of Health
Good health and well-being
Openalex Percentile: Top 11%
Advanced Radiotherapy Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.