Non-zero numerical aperture-corrected data analysis for imaging ellipsometry

Imaging ellipsometry (IE), which integrates single-point ellipsometry with optical microscopy, enables spatially resolved evaluation of thin-film thickness and/or optical constants across a sample surface. Conventional ellipsometry requires a highly collimated incident beam; however, strong collimation degrades spatial resolution in imaging measurements. Moreover, the incoherent light sources typically employed in imaging ellipsometers make it practically difficult to achieve perfect collimation. Consequently, IE operates with a finite convergence angle, i.e., a non-zero numerical aperture (NA). In this work, the influence of NA on ellipsometric measurement accuracy is investigated through numerical simulations using an air/SiO2 thin-film/silicon substrate structure. To mitigate this effect, an NA-corrected data-analysis method is proposed and experimentally validated using a laboratory-built rotating-compensator IE system.

Authors

Institutions

Publication Details

Journal
Journal of Applied Physics
Published
2026-08-27
DOI
https://doi.org/10.1063/5.0340518
Primary Topic
Optical Polarization and Ellipsometry
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Non-zero numerical aperture-corrected data analysis for imaging ellipsometry

Bernard Gelloz, Lianhua Jin, E. Kondoh, Yasuhiro Mizutani et al.
Journal of Applied Physics
Optical Polarization and Ellipsometry
article

Non-zero numerical aperture-corrected data analysis for imaging ellipsometry

Bernard Gelloz, Lianhua Jin, E. Kondoh, Yasuhiro Mizutani, Yuki Harada, T. Inoue, D. Yamaguchi
article en

Abstract

Imaging ellipsometry (IE), which integrates single-point ellipsometry with optical microscopy, enables spatially resolved evaluation of thin-film thickness and/or optical constants across a sample surface. Conventional ellipsometry requires a highly collimated incident beam; however, strong collimation degrades spatial resolution in imaging measurements. Moreover, the incoherent light sources typically employed in imaging ellipsometers make it practically difficult to achieve perfect collimation. Consequently, IE operates with a finite convergence angle, i.e., a non-zero numerical aperture (NA). In this work, the influence of NA on ellipsometric measurement accuracy is investigated through numerical simulations using an air/SiO2 thin-film/silicon substrate structure. To mitigate this effect, an NA-corrected data-analysis method is proposed and experimentally validated using a laboratory-built rotating-compensator IE system.

Journal of Applied PhysicsVol. 140(8)
Université Paris-Panthéon-Assas (FR), Centre National de la Recherche Scientifique (FR), Osaka University of Economics (JP), Inserm (FR), Délégation Paris 6 (FR), Nagoya University (JP), University of Yamanashi (JP), The University of Osaka (JP), ESPCI Paris (FR)
Japan Society for the Promotion of Science
Openalex Percentile: Top 19%
Optical Polarization and Ellipsometry
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.