Experimental Study on Seismic Performance of Through-Tenon Joints with Different Degrees of Looseness

This study investigated the impact of joint looseness on the seismic performance of through-tenon joints in traditional timber structures. The through-tenon joint from the fourth floor of Guangyue Tower served as the research prototype. Five specimens, including one intact joint and four joints with varying looseness levels, were fabricated at a geometric scaling ratio of 1:2. Low-cycle reversed cyclic loading tests were conducted to characterize the mechanical behaviors of all specimens. Evaluation parameters included failure modes, moment–rotation hysteretic curves, skeleton curves, strength degradation curves, stiffness degradation curves, energy dissipation capacity, and ductility performance. The test results revealed that increasing joint looseness transformed the hysteretic curve from an anti-Z shape to an arch shape. This transformation involved aggravated pinching behaviour and evident slippage. All test specimens showed strength degradation coefficients below unity. Loosened joints exhibited lower stiffness and energy dissipation capacity than the intact joint. These properties declined monotonically with increasing looseness levels. Ductility performance revealed a remarkable directional discrepancy under bidirectional loading. Deformation responses diverged notably under positive and negative cyclic loads. All specimens possessed favorable global deformability. Ultimate rotation angles and loading displacements correlated positively with the degree of looseness. Tenon withdrawal deformation continuously accumulated with an increasing rotation angle.

Authors

Institutions

Publication Details

Journal
Buildings
Published
2026-08-27
DOI
https://doi.org/10.3390/buildings16173431
Primary Topic
Wood Treatment and Properties
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Experimental Study on Seismic Performance of Through-Tenon Joints with Different Degrees of Looseness

Zhaobo Meng, Nan Ding, Shanwei Wang, Yu Cao et al.
Buildings
Wood Treatment and Properties
article

Experimental Study on Seismic Performance of Through-Tenon Joints with Different Degrees of Looseness

Zhaobo Meng, Nan Ding, Shanwei Wang, Yu Cao, Liwei Zhang, Jigang Zhang, Wenjing Li, Xiancai Ren
article en

Abstract

This study investigated the impact of joint looseness on the seismic performance of through-tenon joints in traditional timber structures. The through-tenon joint from the fourth floor of Guangyue Tower served as the research prototype. Five specimens, including one intact joint and four joints with varying looseness levels, were fabricated at a geometric scaling ratio of 1:2. Low-cycle reversed cyclic loading tests were conducted to characterize the mechanical behaviors of all specimens. Evaluation parameters included failure modes, moment–rotation hysteretic curves, skeleton curves, strength degradation curves, stiffness degradation curves, energy dissipation capacity, and ductility performance. The test results revealed that increasing joint looseness transformed the hysteretic curve from an anti-Z shape to an arch shape. This transformation involved aggravated pinching behaviour and evident slippage. All test specimens showed strength degradation coefficients below unity. Loosened joints exhibited lower stiffness and energy dissipation capacity than the intact joint. These properties declined monotonically with increasing looseness levels. Ductility performance revealed a remarkable directional discrepancy under bidirectional loading. Deformation responses diverged notably under positive and negative cyclic loads. All specimens possessed favorable global deformability. Ultimate rotation angles and loading displacements correlated positively with the degree of looseness. Tenon withdrawal deformation continuously accumulated with an increasing rotation angle.

BuildingsVol. 16(17)
Qingdao University of Science and Technology (CN), Xi'an University of Architecture and Technology (CN), Liaocheng University (CN), Qingdao University of Technology (CN)
Natural Science Foundation of Gansu Province, Natural Science Foundation of Shandong Province
Sustainable cities and communities
Openalex Percentile: Top 14%
Wood Treatment and Properties
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.