Effect of Axial and Coronal Malalignment on Polyethylene Stresses in Lumbosacral Total Joint Replacement: A Finite Element Study

The purpose of this study was to analyze the sensitivity of polyethylene stresses and strains, as proxies for wear and surface damage, to coronal and axial misalignment for a novel lumbar total joint replacement (LTJR) implanted at L5-S1. We hypothesized that these stresses and strains would remain below the levels associated with worst-case impingement in a spine wear simulator. A finite element model (FEM) of the L4-S1 spine was developed using CT-based anatomy from a representative Investigational Device Exemption study patient. An appropriately sized LTJR was virtually implanted at L5-S1 in a standardized baseline orientation, and component positioning was altered to achieve eight independent misalignment scenarios, spanning axial convergence angle, anterior–posterior offset, and coronal tilt. Physiologic forward-bending loads were applied, and polyethylene contact pressure, von Mises stress, and effective strain were recorded. Peak values for the baseline scenario were 35.0 MPa, 19.9 MPa, and 4.8%, respectively. Convergence angle and anterior–posterior offset had minimal effect, whereas coronal tilt produced the largest changes. Contact pressure and von Mises stress varied by <20% due to misalignment, whereas effective strain was more sensitive, increasing from 4.8% at baseline to 9.9% with 20 degrees of coronal tilt. All values were comparable to prior L4-L5 findings and remained well below impingement levels. Within the bounds of reasonable misalignment, the device maintained bearing congruency and did not approach conditions associated with accelerated wear.

Authors

Institutions

Publication Details

Journal
Bioengineering
Published
2026-08-27
DOI
https://doi.org/10.3390/bioengineering13090987
Primary Topic
Spine and Intervertebral Disc Pathology
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Effect of Axial and Coronal Malalignment on Polyethylene Stresses in Lumbosacral Total Joint Replacement: A Finite Element Study

Hannah Spece, Steven A. Rundell, Steven M. Kurtz, Ron V. Yarbrough et al.
Bioengineering
Spine and Intervertebral Disc Pathology
article

Effect of Axial and Coronal Malalignment on Polyethylene Stresses in Lumbosacral Total Joint Replacement: A Finite Element Study

Hannah Spece, Steven A. Rundell, Steven M. Kurtz, Ron V. Yarbrough, Scott D. Hodges
article en

Abstract

The purpose of this study was to analyze the sensitivity of polyethylene stresses and strains, as proxies for wear and surface damage, to coronal and axial misalignment for a novel lumbar total joint replacement (LTJR) implanted at L5-S1. We hypothesized that these stresses and strains would remain below the levels associated with worst-case impingement in a spine wear simulator. A finite element model (FEM) of the L4-S1 spine was developed using CT-based anatomy from a representative Investigational Device Exemption study patient. An appropriately sized LTJR was virtually implanted at L5-S1 in a standardized baseline orientation, and component positioning was altered to achieve eight independent misalignment scenarios, spanning axial convergence angle, anterior–posterior offset, and coronal tilt. Physiologic forward-bending loads were applied, and polyethylene contact pressure, von Mises stress, and effective strain were recorded. Peak values for the baseline scenario were 35.0 MPa, 19.9 MPa, and 4.8%, respectively. Convergence angle and anterior–posterior offset had minimal effect, whereas coronal tilt produced the largest changes. Contact pressure and von Mises stress varied by <20% due to misalignment, whereas effective strain was more sensitive, increasing from 4.8% at baseline to 9.9% with 20 degrees of coronal tilt. All values were comparable to prior L4-L5 findings and remained well below impingement levels. Within the bounds of reasonable misalignment, the device maintained bearing congruency and did not approach conditions associated with accelerated wear.

BioengineeringVol. 13(9)
Polaroid (United States) (US), University of Tennessee at Chattanooga (US), Motion Control (United States) (US), Detroit R&D (United States) (US), Drexel University (US)
Peace, Justice and strong institutions
Openalex Percentile: Top 10%
Spine and Intervertebral Disc Pathology
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.