Improved Accuracy of Multidimensional Spatially‐Selective Saturation RF Pulses for Short‐Repetition‐Time Steady‐State Imaging

ABSTRACT Purpose To introduce and evaluate a novel RF pulse design algorithm for multi‐dimensional spatially tailored excitation that is optimized for spoiled steady‐state gradient echo MRI sequences. Methods Existing multi‐dimensional RF pulse design algorithms optimize RF and gradient waveforms using a loss function based on a single RF pulse application. These designs are poorly suited for steady‐state MRI sequences where RF pulses are spaced only tens of milliseconds apart, causing potentially large differences between the steady‐state magnetization and the target pattern. We propose a multidimensional RF pulse design algorithm with a loss function based on the steady‐state magnetization of a spoiled gradient‐echo sequence. Our algorithm, steady‐state AutoDiffPulses (SS‐ADP), extends the previously introduced ADP framework for joint RF and gradient pulse design. We evaluated design accuracy and RF energy in phantom and in vivo brain imaging in inner‐volume (IV) and outer‐volume (OV) saturation experiments. We further evaluated the potential of SS‐ADP to improve reduced FOV (rFOV) imaging. Results SS‐ADP produced significantly more accurate steady‐state magnetization patterns compared to a conventional single‐excitation design (ADP), with significantly reduced RF energy, for . Furthermore, utilizing SS‐ADP for outer‐volume suppression (OVS) substantially reduced reconstruction error in accelerated rFOV imaging compared to conventional ADP‐OVS. Conclusion A joint RF and gradient pulse design algorithm accounting for steady‐state magnetization evolution significantly improves excitation accuracy and reduces SAR in short‐TR spoiled imaging with .

Authors

Institutions

Publication Details

Journal
Magnetic Resonance in Medicine
Published
2026-08-26
DOI
https://doi.org/10.1002/mrm.70573
Primary Topic
Advanced MRI Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Improved Accuracy of Multidimensional Spatially‐Selective Saturation RF Pulses for Short‐Repetition‐Time Steady‐State Imaging

Jon‐Fredrik Nielsen, Douglas C. Noll, Yongli He
Magnetic Resonance in Medicine
Advanced MRI Techniques and Applications
article

Improved Accuracy of Multidimensional Spatially‐Selective Saturation RF Pulses for Short‐Repetition‐Time Steady‐State Imaging

Jon‐Fredrik Nielsen, Douglas C. Noll, Yongli He
article en

Abstract

ABSTRACT Purpose To introduce and evaluate a novel RF pulse design algorithm for multi‐dimensional spatially tailored excitation that is optimized for spoiled steady‐state gradient echo MRI sequences. Methods Existing multi‐dimensional RF pulse design algorithms optimize RF and gradient waveforms using a loss function based on a single RF pulse application. These designs are poorly suited for steady‐state MRI sequences where RF pulses are spaced only tens of milliseconds apart, causing potentially large differences between the steady‐state magnetization and the target pattern. We propose a multidimensional RF pulse design algorithm with a loss function based on the steady‐state magnetization of a spoiled gradient‐echo sequence. Our algorithm, steady‐state AutoDiffPulses (SS‐ADP), extends the previously introduced ADP framework for joint RF and gradient pulse design. We evaluated design accuracy and RF energy in phantom and in vivo brain imaging in inner‐volume (IV) and outer‐volume (OV) saturation experiments. We further evaluated the potential of SS‐ADP to improve reduced FOV (rFOV) imaging. Results SS‐ADP produced significantly more accurate steady‐state magnetization patterns compared to a conventional single‐excitation design (ADP), with significantly reduced RF energy, for . Furthermore, utilizing SS‐ADP for outer‐volume suppression (OVS) substantially reduced reconstruction error in accelerated rFOV imaging compared to conventional ADP‐OVS. Conclusion A joint RF and gradient pulse design algorithm accounting for steady‐state magnetization evolution significantly improves excitation accuracy and reduces SAR in short‐TR spoiled imaging with .

Magnetic Resonance in Medicine
University of Michigan (US)
Affordable and clean energy
Openalex Percentile: Top 10%
Advanced MRI Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Improved Accuracy of Multidimensional Spatially‐Selective Saturation RF Pulses for Short‐Repetition‐Time Steady‐State Imaging — Jon‐Fredrik Nielsen, Douglas C. Noll, et al. · Magnetic Resonance in Medicine (2026) | TGRS Research Map | TGRS