Automated CO2 insufflation and image quality in CT colonography

Introduction CT colonography is an established technique for detecting polyps and colorectal cancer, particularly in patients unable to undergo conventional colonoscopy. The aim of this study was to evaluate the volume of automated CO 2 insufflation, radiation dose, and diagnostic image quality in patients undergoing CT colonography. Methods This single-centre retrospective study included patients referred for CT colonography following incomplete or contraindicated colonoscopy. Examinations were performed in supine and prone positions. Radiation dose for each position was collected, including CT dose index volume (CTDI) and dose–length product (DLP). Colonic distention was graded from radiology reports by four radiologists using a five-point Likert scale (1 = poor, 5=excellent); examinations were classified as diagnostic or non-diagnostic. Statistical analysis examined the association between CO 2 insufflation volume and image quality. Results A total of 243 CT colonography examinations (188 women, 55 men; median age 71 years) were analysed. The median CO 2 insufflation volume was 6 L (range 1.5–16 L). Median total DLP was 594 mGy cm (IQR 438.8–866.1). Overall, 222 examinations (91.4%) were considered diagnostic, while 21 (8.6%) were non-diagnostic. Colonic distention was rated as excellent in 131 cases (53.9%), good in 25 (10.3%), sufficient in 41 (16.9%), suboptimal in 35 (14.4%), and poor in 11 (4.5%). Conclusion A median of 6 L of CO 2 was used to achieve diagnostic colonic distention, with a median radiation dose of 594 mGy cm. Most examinations in the study achieved an image quality score of 4 or higher, sufficient for accurate interpretation. Implications for practice Higher-than-expected CO 2 volumes were observed, highlighting the importance of optimizing insufflation protocols to balance image quality, and standardization in clinical practice.

Authors

Institutions

Publication Details

Journal
Radiography
Published
2026-08-27
DOI
https://doi.org/10.1016/j.radi.2026.103552
Primary Topic
Advanced X-ray and CT Imaging
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Automated CO2 insufflation and image quality in CT colonography

Malene Roland Vils Pedersen, Søren Rafael Rafaelsen, J.M. Jensen, Helle Precht et al.
Radiography
Advanced X-ray and CT Imaging
article

Automated CO2 insufflation and image quality in CT colonography

Malene Roland Vils Pedersen, Søren Rafael Rafaelsen, J.M. Jensen, Helle Precht, Torben Frøstrup Hansen, D.M. Toft, S.D. Mørup
article en

Abstract

Introduction CT colonography is an established technique for detecting polyps and colorectal cancer, particularly in patients unable to undergo conventional colonoscopy. The aim of this study was to evaluate the volume of automated CO 2 insufflation, radiation dose, and diagnostic image quality in patients undergoing CT colonography. Methods This single-centre retrospective study included patients referred for CT colonography following incomplete or contraindicated colonoscopy. Examinations were performed in supine and prone positions. Radiation dose for each position was collected, including CT dose index volume (CTDI) and dose–length product (DLP). Colonic distention was graded from radiology reports by four radiologists using a five-point Likert scale (1 = poor, 5=excellent); examinations were classified as diagnostic or non-diagnostic. Statistical analysis examined the association between CO 2 insufflation volume and image quality. Results A total of 243 CT colonography examinations (188 women, 55 men; median age 71 years) were analysed. The median CO 2 insufflation volume was 6 L (range 1.5–16 L). Median total DLP was 594 mGy cm (IQR 438.8–866.1). Overall, 222 examinations (91.4%) were considered diagnostic, while 21 (8.6%) were non-diagnostic. Colonic distention was rated as excellent in 131 cases (53.9%), good in 25 (10.3%), sufficient in 41 (16.9%), suboptimal in 35 (14.4%), and poor in 11 (4.5%). Conclusion A median of 6 L of CO 2 was used to achieve diagnostic colonic distention, with a median radiation dose of 594 mGy cm. Most examinations in the study achieved an image quality score of 4 or higher, sufficient for accurate interpretation. Implications for practice Higher-than-expected CO 2 volumes were observed, highlighting the importance of optimizing insufflation protocols to balance image quality, and standardization in clinical practice.

RadiographyVol. 32(7)
University of Southern Denmark (DK), Vejle Sygehus (DK), Region of Southern Denmark (DK)
Syddansk Universitet
Zero hunger
Openalex Percentile: Top 19%
Advanced X-ray and CT Imaging
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.