Delivery of Nebulized Prebiotic/Postbiotic Formulations: Spatial Deposition and Exposure Characterization by GC–MS

Indoor environments are increasingly recognized as key determinants of human microbial exposure and skin health. Microbiome-aware interventions, including probiotic and prebiotic formulations, have been proposed to complement conventional environmental hygiene. However, quantitative data on the spatial distribution of nebulized prebiotic/postbiotic mixtures in enclosed spaces are lacking. The aim of this exploratory study was to characterize the aerosolization efficiency and spatial deposition of a prebiotic/postbiotic solution nebulized by two different devices in standardized indoor microenvironments. Two nebulizing devices were tested separately in two identical 20′ ISO containers (33.2 m3). A liquid prebiotic/postbiotic mixture at two concentrations (10% and 20% v/v in water) was nebulized for 1 or 2 h. Surface deposition was assessed using passive paper samplers placed at horizontal distances of 0, 25, 50, 100 and 200 cm from the aerosol outlet. A volatile chemical marker contained in the solution was quantified by gas chromatography–mass spectrometry to estimate deposited volume per unit area. Both devices generated detectable marker deposition at all distances, ranging from 0.22 to 14.42 µL·cm−2 of concentrate equivalent. In a mixed-effects model treating the individual run as the unit of replication, distance was the only factor reaching statistical significance, deposition decreasing approximately twofold per 100 cm (p < 0.001); the apparent effects of device type, concentration and run time did not reach significance. Spatial decay profiles were condition-dependent rather than systematically device-specific. Nebulized prebiotic/postbiotic mixtures can be delivered across meter-scale distances in enclosed indoor settings. Because each condition was tested in a single run, aerosol properties were not characterized and no microbiological or clinical endpoints were assessed; these findings represent a feasibility and exposure-characterization step rather than evidence of biological or health benefit, and they support further investigation of nebulized microbiome-modulating interventions in environmental and occupational medicine.

Authors

Institutions

Publication Details

Journal
International Journal of Environmental Medicine
Published
2026-08-27
DOI
https://doi.org/10.3390/ijem1030015
Primary Topic
Indoor Air Quality and Microbial Exposure
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Delivery of Nebulized Prebiotic/Postbiotic Formulations: Spatial Deposition and Exposure Characterization by GC–MS

Claudio De Maio, Edoardo Cavalieri d’Oro, Enrico Greco, Rita White
International Journal of Environmental Medicine
Indoor Air Quality and Microbial Exposure
article

Delivery of Nebulized Prebiotic/Postbiotic Formulations: Spatial Deposition and Exposure Characterization by GC–MS

Claudio De Maio, Edoardo Cavalieri d’Oro, Enrico Greco, Rita White
article en

Abstract

Indoor environments are increasingly recognized as key determinants of human microbial exposure and skin health. Microbiome-aware interventions, including probiotic and prebiotic formulations, have been proposed to complement conventional environmental hygiene. However, quantitative data on the spatial distribution of nebulized prebiotic/postbiotic mixtures in enclosed spaces are lacking. The aim of this exploratory study was to characterize the aerosolization efficiency and spatial deposition of a prebiotic/postbiotic solution nebulized by two different devices in standardized indoor microenvironments. Two nebulizing devices were tested separately in two identical 20′ ISO containers (33.2 m3). A liquid prebiotic/postbiotic mixture at two concentrations (10% and 20% v/v in water) was nebulized for 1 or 2 h. Surface deposition was assessed using passive paper samplers placed at horizontal distances of 0, 25, 50, 100 and 200 cm from the aerosol outlet. A volatile chemical marker contained in the solution was quantified by gas chromatography–mass spectrometry to estimate deposited volume per unit area. Both devices generated detectable marker deposition at all distances, ranging from 0.22 to 14.42 µL·cm−2 of concentrate equivalent. In a mixed-effects model treating the individual run as the unit of replication, distance was the only factor reaching statistical significance, deposition decreasing approximately twofold per 100 cm (p < 0.001); the apparent effects of device type, concentration and run time did not reach significance. Spatial decay profiles were condition-dependent rather than systematically device-specific. Nebulized prebiotic/postbiotic mixtures can be delivered across meter-scale distances in enclosed indoor settings. Because each condition was tested in a single run, aerosol properties were not characterized and no microbiological or clinical endpoints were assessed; these findings represent a feasibility and exposure-characterization step rather than evidence of biological or health benefit, and they support further investigation of nebulized microbiome-modulating interventions in environmental and occupational medicine.

International Journal of Environmental MedicineVol. 1(3)
University of Bucharest (RO), University of South Florida (US), National Interuniversity Consortium of Materials Science and Technology (IT), Regione Lombardia
Openalex Percentile: Top 11%
Indoor Air Quality and Microbial Exposure
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.