A Flexible Carbon Nanofiber-Modified Multi-Channel Electrode Enables High-Sensitivity Electrochemical Detection of Multiple Neuroactive Molecules

Electrochemical detection is widely acknowledged as a promising technique for quantifying neuroactive molecules, credited to its low cost, portable hardware, and distinctive ability to enable in vivo real-time dynamic monitoring. However, key hurdles still block the technology’s standardization, commercial clinical translation, and on-site application, including poor biocompatibility at the sensing interface, inadequate mechanical stability, and restricted detection generality. To address these drawbacks, this work introduces a multi-channel flexible microwire electrode array. Here, carbon-based nanomaterials build a high-conductivity internal backbone and an analyte-concentrating sensing surface, while chitosan (CS) supports film formation and boosts biocompatibility. These two composite film layers were modified onto the gold surface of MEMS-fabricated flexible microelectrodes via electrophoretic deposition. At optimized voltage and deposition duration, the carbon nanofiber (CNF)-modified electrode outperformed both nitrogen-doped reduced graphene oxide (NGO) electrodes and unmodified gold electrodes. It delivered strong, well-resolved responses for tyrosine, tryptophan, norepinephrine, melatonin, and tryptamine, with detection limits of 9, 45, 50, 15, and 20 μM, respectively, alongside high reproducibility and promising initial stability. Capitalizing on the CS/CNF-Au electrode’s excellent mechanical and electrical performance, this study verifies that tuned carbon-based composite layers enable high-performance electrochemical interfaces, offering a new route to develop flexible universal detection platforms that integrate both biocompatibility and structural reliability.

Authors

Institutions

Publication Details

Journal
Sensors
Published
2026-08-27
DOI
https://doi.org/10.3390/s26175413
Primary Topic
Electrochemical sensors and biosensors
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Flexible Carbon Nanofiber-Modified Multi-Channel Electrode Enables High-Sensitivity Electrochemical Detection of Multiple Neuroactive Molecules

Ji Dai, Xiaojian Li, Zhiting Zhang, Jiao Zhang et al.
Sensors
Electrochemical sensors and biosensors
article

A Flexible Carbon Nanofiber-Modified Multi-Channel Electrode Enables High-Sensitivity Electrochemical Detection of Multiple Neuroactive Molecules

Ji Dai, Xiaojian Li, Zhiting Zhang, Jiao Zhang, Chunshan Deng
article en

Abstract

Electrochemical detection is widely acknowledged as a promising technique for quantifying neuroactive molecules, credited to its low cost, portable hardware, and distinctive ability to enable in vivo real-time dynamic monitoring. However, key hurdles still block the technology’s standardization, commercial clinical translation, and on-site application, including poor biocompatibility at the sensing interface, inadequate mechanical stability, and restricted detection generality. To address these drawbacks, this work introduces a multi-channel flexible microwire electrode array. Here, carbon-based nanomaterials build a high-conductivity internal backbone and an analyte-concentrating sensing surface, while chitosan (CS) supports film formation and boosts biocompatibility. These two composite film layers were modified onto the gold surface of MEMS-fabricated flexible microelectrodes via electrophoretic deposition. At optimized voltage and deposition duration, the carbon nanofiber (CNF)-modified electrode outperformed both nitrogen-doped reduced graphene oxide (NGO) electrodes and unmodified gold electrodes. It delivered strong, well-resolved responses for tyrosine, tryptophan, norepinephrine, melatonin, and tryptamine, with detection limits of 9, 45, 50, 15, and 20 μM, respectively, alongside high reproducibility and promising initial stability. Capitalizing on the CS/CNF-Au electrode’s excellent mechanical and electrical performance, this study verifies that tuned carbon-based composite layers enable high-performance electrochemical interfaces, offering a new route to develop flexible universal detection platforms that integrate both biocompatibility and structural reliability.

SensorsVol. 26(17)
Chinese Academy of Sciences (CN), Southern University of Science and Technology (CN), Shenzhen University Health Science Center (CN), Shenzhen Institutes of Advanced Technology (CN), Shenzhen Technology University (CN), University of Chinese Academy of Sciences (CN)
National Natural Science Foundation of China, National Key Research and Development Program of China
Openalex Percentile: Top 19%
Electrochemical sensors and biosensors
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.