Low‐Field MRI as a Multiparametric Tool for Large Engineered Tissue Characterization

Advances in 3D bioprinting have enabled the fabrication of large and complex engineered tissues, but their increasing size demands non-invasive tools for monitoring structure, maturation, and perfusion. Magnetic Resonance Imaging (MRI) offers unique multiparametric capabilities, yet high-field systems remain costly and inaccessible for most laboratories. In this study, we evaluate the potential of low-field MRI (LF MRI, 0.3 T) as an affordable and versatile alternative to high-field MRI (HF MRI, 7 T) for characterizing bioprinted tissue constructs. Using standardized PLA and hydrogel scaffolds within a custom-designed perfusion chamber, we compared LF and HF imaging performance for morphology and flow visualization. Both modalities successfully resolved internal scaffold features, with morphometric deviations from reference CAD models remaining within quality control tolerances. Flow imaging demonstrated that LF MRI could capture velocity distributions consistent with HF measurements and computational fluid dynamics simulations, even revealing fabrication-induced defects such as channel collapse or occlusion. Finally, we applied LF MRI for longitudinal monitoring of a perfused adipose tissue construct over 34 days. This approach enabled repeated non-destructive assessments of morphology and perfusion, with final histological analyses confirming homogeneous adipogenic differentiation and extracellular matrix deposition. Together, these results establish LF MRI as a powerful tool for real-time, non-invasive evaluation of biofabricated tissues. By combining affordability, portability, and multiparametric imaging capacity, LF MRI broadens access to advanced monitoring strategies in tissue engineering and regenerative medicine, supporting both quality control and functional assessment of large-scale engineered constructs.

Authors

Institutions

Publication Details

Journal
Biotechnology and Bioengineering
Published
2026-08-26
DOI
https://doi.org/10.1002/bit.70329
Primary Topic
3D Printing in Biomedical Research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
article

Low‐Field MRI as a Multiparametric Tool for Large Engineered Tissue Characterization

Simon A. Lambert, Lucie Essayan, Emma Petiot, V. Semet et al.
Biotechnology and Bioengineering
3D Printing in Biomedical Research
article

Low‐Field MRI as a Multiparametric Tool for Large Engineered Tissue Characterization

Simon A. Lambert, Lucie Essayan, Emma Petiot, V. Semet, Christophe A. Marquette, Valernst Martial Gilmus, Yilbert Gimenez, Elliott Cowles, Michel Cabrera
article en

Abstract

Advances in 3D bioprinting have enabled the fabrication of large and complex engineered tissues, but their increasing size demands non-invasive tools for monitoring structure, maturation, and perfusion. Magnetic Resonance Imaging (MRI) offers unique multiparametric capabilities, yet high-field systems remain costly and inaccessible for most laboratories. In this study, we evaluate the potential of low-field MRI (LF MRI, 0.3 T) as an affordable and versatile alternative to high-field MRI (HF MRI, 7 T) for characterizing bioprinted tissue constructs. Using standardized PLA and hydrogel scaffolds within a custom-designed perfusion chamber, we compared LF and HF imaging performance for morphology and flow visualization. Both modalities successfully resolved internal scaffold features, with morphometric deviations from reference CAD models remaining within quality control tolerances. Flow imaging demonstrated that LF MRI could capture velocity distributions consistent with HF measurements and computational fluid dynamics simulations, even revealing fabrication-induced defects such as channel collapse or occlusion. Finally, we applied LF MRI for longitudinal monitoring of a perfused adipose tissue construct over 34 days. This approach enabled repeated non-destructive assessments of morphology and perfusion, with final histological analyses confirming homogeneous adipogenic differentiation and extracellular matrix deposition. Together, these results establish LF MRI as a powerful tool for real-time, non-invasive evaluation of biofabricated tissues. By combining affordability, portability, and multiparametric imaging capacity, LF MRI broadens access to advanced monitoring strategies in tissue engineering and regenerative medicine, supporting both quality control and functional assessment of large-scale engineered constructs.

Biotechnology and Bioengineering
Université Claude Bernard Lyon 1 (FR), Centre National de la Recherche Scientifique (FR), Laboratoire Ampère (FR), Institut National des Sciences Appliquées de Lyon (FR)
Openalex Percentile: Top 19%
3D Printing in Biomedical Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.