Systematic evaluation of foundation models for organ-level classification on CT scans

Abstract Purpose Foundation models are increasingly used as frozen feature extractors for CT classification tasks, yet the determinants of their downstream performance remain unclear. We assess how foundation model choice, feature aggregation strategy, and abnormality type are associated with performance in organ-level abnormality classification. We further evaluate whether more expressive aggregation strategies outperform simple pooling, and whether performance varies by abnormality type. Methods We evaluate five state-of-the-art medical imaging foundation models on binary organ-level abnormality classification (normal vs. abnormal) across six abdominal organs. Local patch-level embeddings are aggregated using six strategies, including simple pooling methods (e.g., mean pooling) and attention-based multiple instance learning. A linear classifier is trained on feature embeddings, and performance is evaluated on an annotated test set of 200 CT scans. Results Among the evaluated models, 3D CT-native models generally outperformed 2D multi-modal models. None of the tested aggregation strategies significantly outperformed mean pooling, including attention-based multiple instance learning (best-performing aggregation vs. mean: $$\Delta $$ Δ AUC = 0.008, 95% CI $$[-0.002, 0.022]$$ [ - 0.002 , 0.022 ] ). In our organ-level classification setting, performance differed between abnormality type for all well-performing models (SPECTRE, TAP-CT, CT-FM), with lower AUCs observed for focal abnormalities compared to diffuse abnormalities (largest difference: $$\Delta $$ Δ AUC = 0.108, 95% CI [0.080, 0.135]). This gap was not reduced by the evaluated aggregation strategies. Conclusion In our experiments, downstream performance varied more across foundation models than across aggregation strategies. The choice of aggregation strategy, including attention-based multiple instance learning, did not significantly impact performance in this setting. The persistent gap for focal abnormalities suggests that current representations may insufficiently encode localized disease patterns, motivating the development of localization-aware pre-training approaches.

Authors

Institutions

Publication Details

Journal
International Journal of Computer Assisted Radiology and Surgery
Published
2026-08-27
DOI
https://doi.org/10.1007/s11548-026-03786-x
Primary Topic
COVID-19 diagnosis using AI
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Systematic evaluation of foundation models for organ-level classification on CT scans

Colin Jacobs, Fennie Van der Graaf, Sarah de Boer, Ewoud J. Smit et al.
International Journal of Computer Assisted Radiology and Surgery
COVID-19 diagnosis using AI
article

Systematic evaluation of foundation models for organ-level classification on CT scans

Colin Jacobs, Fennie Van der Graaf, Sarah de Boer, Ewoud J. Smit, Alessa Hering, Lena Philipp, Jan Tagscherer
article en

Abstract

Abstract Purpose Foundation models are increasingly used as frozen feature extractors for CT classification tasks, yet the determinants of their downstream performance remain unclear. We assess how foundation model choice, feature aggregation strategy, and abnormality type are associated with performance in organ-level abnormality classification. We further evaluate whether more expressive aggregation strategies outperform simple pooling, and whether performance varies by abnormality type. Methods We evaluate five state-of-the-art medical imaging foundation models on binary organ-level abnormality classification (normal vs. abnormal) across six abdominal organs. Local patch-level embeddings are aggregated using six strategies, including simple pooling methods (e.g., mean pooling) and attention-based multiple instance learning. A linear classifier is trained on feature embeddings, and performance is evaluated on an annotated test set of 200 CT scans. Results Among the evaluated models, 3D CT-native models generally outperformed 2D multi-modal models. None of the tested aggregation strategies significantly outperformed mean pooling, including attention-based multiple instance learning (best-performing aggregation vs. mean: $$\Delta $$ Δ AUC = 0.008, 95% CI $$[-0.002, 0.022]$$ [ - 0.002 , 0.022 ] ). In our organ-level classification setting, performance differed between abnormality type for all well-performing models (SPECTRE, TAP-CT, CT-FM), with lower AUCs observed for focal abnormalities compared to diffuse abnormalities (largest difference: $$\Delta $$ Δ AUC = 0.108, 95% CI [0.080, 0.135]). This gap was not reduced by the evaluated aggregation strategies. Conclusion In our experiments, downstream performance varied more across foundation models than across aggregation strategies. The choice of aggregation strategy, including attention-based multiple instance learning, did not significantly impact performance in this setting. The persistent gap for focal abnormalities suggests that current representations may insufficiently encode localized disease patterns, motivating the development of localization-aware pre-training approaches.

International Journal of Computer Assisted Radiology and Surgery
Radboud University Nijmegen (NL), Radboud University Medical Center (NL), Radboud Institute for Molecular Life Sciences (NL)
Nederlandse Organisatie voor Wetenschappelijk Onderzoek, HORIZON EUROPE Health
Openalex Percentile: Top 11%
COVID-19 diagnosis using AI
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.