Comparison Study between 3D FLAIR Sequence and 3D Double Inversion Recovery compared in the Detection of Juxtacortical/cortical Lesions in MS Patients

Introduction Multiple sclerosis (MS) is a chronic inflammatory and neurodegenerative disorder of the central nervous system, characterized by demyelination, axonal injury, and progressive neuronal loss. This study sought to evaluate and compare the ability of double inversion recovery 3D (DIR) and 3D FLAIR sequences to identify cortical and juxtacortical lesions in individuals with multiple sclerosis. Methods Participants were recruited in this cross-sectional study at Yarmouk Teaching Hospital between June 2025 and January 2026. Forty-nine consecutive patients with multiple sclerosis (all clinical phenotypes) were included. Each subject underwent evaluation using the two imaging modalities as part of routine clinical assessment. MRI examinations were performed on a 3-Tesla Philips Achieva scanner (Philips Healthcare, Best, the Netherlands) using a 16-channel head coil. The imaging protocol included 3D DIR and 3D FLAIR sequences acquired as part of the routine evaluation of patients with multiple sclerosis. For study purposes, lesion detection using the two sequences was compared. Results There were 31 females, accounting for 63.3%, and 18 males. The mean age was 36.6 Añ 6.97 years. Mixed-effects negative binomial regression demonstrated that 3D DIR detected significantly more lesions than 3D FLAIR. The detection rate was approximately 55% higher with 3D DIR (IRR 1.55, 95% CI 1.2-1.99, p <0.001). Age and gender were not independently associated with lesion counts. Adjusted marginal estimates showed mean detections of 3.10 lesions with 3D DIR compared with 2.01 using 3D FLAIR. Discussion This study has several important strengths. First, the paired design, in which each patient underwent both imaging modalities, reduced between-subject variability and allowed direct within-patient comparison. Second, the consistency of findings across patients-with most showing higher lesion detection using 3D DIR-strengthens the credibility and clinical relevance of the results. Several limitations should be acknowledged. The study was conducted in a single center, which may limit generalizability. Additionally, relevant clinical or imaging factors such as lesion characteristics or location were not included in the model, and the analysis focused on lesion counts rather than diagnostic accuracy or long-term clinical outcomes. Conclusion 3D DIR significantly improved lesion detection, identifying approximately 55% more lesions than 3D FLAIR independent of age and gender.

Authors

Institutions

Publication Details

Journal
The Open Neurology Journal
Published
2026-08-27
DOI
https://doi.org/10.2174/011874205x501326260824164144
Primary Topic
Multiple Sclerosis Research Studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Comparison Study between 3D FLAIR Sequence and 3D Double Inversion Recovery compared in the Detection of Juxtacortical/cortical Lesions in MS Patients

Maryam Issa Al-Ani, Mohammed Tareq Mutar, Huda Sabeeh Mashhadani, Farah Akram Al Mahdawi
The Open Neurology Journal
Multiple Sclerosis Research Studies
article

Comparison Study between 3D FLAIR Sequence and 3D Double Inversion Recovery compared in the Detection of Juxtacortical/cortical Lesions in MS Patients

Maryam Issa Al-Ani, Mohammed Tareq Mutar, Huda Sabeeh Mashhadani, Farah Akram Al Mahdawi
article en

Abstract

Introduction Multiple sclerosis (MS) is a chronic inflammatory and neurodegenerative disorder of the central nervous system, characterized by demyelination, axonal injury, and progressive neuronal loss. This study sought to evaluate and compare the ability of double inversion recovery 3D (DIR) and 3D FLAIR sequences to identify cortical and juxtacortical lesions in individuals with multiple sclerosis. Methods Participants were recruited in this cross-sectional study at Yarmouk Teaching Hospital between June 2025 and January 2026. Forty-nine consecutive patients with multiple sclerosis (all clinical phenotypes) were included. Each subject underwent evaluation using the two imaging modalities as part of routine clinical assessment. MRI examinations were performed on a 3-Tesla Philips Achieva scanner (Philips Healthcare, Best, the Netherlands) using a 16-channel head coil. The imaging protocol included 3D DIR and 3D FLAIR sequences acquired as part of the routine evaluation of patients with multiple sclerosis. For study purposes, lesion detection using the two sequences was compared. Results There were 31 females, accounting for 63.3%, and 18 males. The mean age was 36.6 Añ 6.97 years. Mixed-effects negative binomial regression demonstrated that 3D DIR detected significantly more lesions than 3D FLAIR. The detection rate was approximately 55% higher with 3D DIR (IRR 1.55, 95% CI 1.2-1.99, p <0.001). Age and gender were not independently associated with lesion counts. Adjusted marginal estimates showed mean detections of 3.10 lesions with 3D DIR compared with 2.01 using 3D FLAIR. Discussion This study has several important strengths. First, the paired design, in which each patient underwent both imaging modalities, reduced between-subject variability and allowed direct within-patient comparison. Second, the consistency of findings across patients-with most showing higher lesion detection using 3D DIR-strengthens the credibility and clinical relevance of the results. Several limitations should be acknowledged. The study was conducted in a single center, which may limit generalizability. Additionally, relevant clinical or imaging factors such as lesion characteristics or location were not included in the model, and the analysis focused on lesion counts rather than diagnostic accuracy or long-term clinical outcomes. Conclusion 3D DIR significantly improved lesion detection, identifying approximately 55% more lesions than 3D FLAIR independent of age and gender.

The Open Neurology JournalVol. 20(1)
University of Baghdad (IQ), Mustansiriyah University (IQ)
Good health and well-being
Openalex Percentile: Top 11%
Multiple Sclerosis Research Studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.