Feasibility and Evaluation of Effective Morphological Feature Representation for Contactless Blood Pressure Estimation Using Remote Photoplethysmography

This study evaluates the feasibility of morphological feature-based contactless blood pressure (BP) estimation using remote photoplethysmography (rPPG). A total of 52 morphological features are extracted from each cardiac cycle of rPPG and its first and second derivatives and arranges as temporal sequences for a long short-term memory (LSTM)-based model. In a calibration-based evaluation on a 16-subject public dataset, the 52-feature model achieved mean absolute errors (MAEs) of 11.45 mmHg for systolic BP (SBP) and 8.15 mmHg for diastolic BP (DBP), outperforming direct rPPG waveform input under the same training protocol. Model comparisons also showed that estimation performance varied with the architecture and model capacity. To identify an effective feature representation, recursive feature elimination (RFE) and principal component analysis (PCA) were compared across multiple dimensions. At 24 dimensions, PCA reduced MAE by 1.59 mmHg for SBP and 1.09 mmHg for DBP relative to RFE, while the 15-dimensional PCA representation was selected as the final compact representation considering both performance and feature dimension. The proposed approach was further evaluated against measurement-free and measurement-based reference baselines, while leave-one-subject-out (LOSO) validation was used to assess subject-independent generalization. LOSO showed substantial performance variation across held-out subjects, indicating limited generalizability to unseen subjects. Despite this limitation, the overall results support the feasibility of compact morphological rPPG feature representations for contactless BP estimation and highlight the importance of appropriate feature-space and model selection.

Authors

Institutions

Publication Details

Journal
Electronics
Published
2026-08-27
DOI
https://doi.org/10.3390/electronics15173864
Primary Topic
Non-Invasive Vital Sign Monitoring
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Feasibility and Evaluation of Effective Morphological Feature Representation for Contactless Blood Pressure Estimation Using Remote Photoplethysmography

Seok‐Young Lee, Nam Kyu Kwon, Hyojin Jo, Dogyun Park
Electronics
Non-Invasive Vital Sign Monitoring
article

Feasibility and Evaluation of Effective Morphological Feature Representation for Contactless Blood Pressure Estimation Using Remote Photoplethysmography

Seok‐Young Lee, Nam Kyu Kwon, Hyojin Jo, Dogyun Park
article en

Abstract

This study evaluates the feasibility of morphological feature-based contactless blood pressure (BP) estimation using remote photoplethysmography (rPPG). A total of 52 morphological features are extracted from each cardiac cycle of rPPG and its first and second derivatives and arranges as temporal sequences for a long short-term memory (LSTM)-based model. In a calibration-based evaluation on a 16-subject public dataset, the 52-feature model achieved mean absolute errors (MAEs) of 11.45 mmHg for systolic BP (SBP) and 8.15 mmHg for diastolic BP (DBP), outperforming direct rPPG waveform input under the same training protocol. Model comparisons also showed that estimation performance varied with the architecture and model capacity. To identify an effective feature representation, recursive feature elimination (RFE) and principal component analysis (PCA) were compared across multiple dimensions. At 24 dimensions, PCA reduced MAE by 1.59 mmHg for SBP and 1.09 mmHg for DBP relative to RFE, while the 15-dimensional PCA representation was selected as the final compact representation considering both performance and feature dimension. The proposed approach was further evaluated against measurement-free and measurement-based reference baselines, while leave-one-subject-out (LOSO) validation was used to assess subject-independent generalization. LOSO showed substantial performance variation across held-out subjects, indicating limited generalizability to unseen subjects. Despite this limitation, the overall results support the feasibility of compact morphological rPPG feature representations for contactless BP estimation and highlight the importance of appropriate feature-space and model selection.

ElectronicsVol. 15(17)
Sejong University (KR), Korea Institute of Robot and Convergence (KR), Yeungnam University (KR)
National Research Foundation of Korea
Openalex Percentile: Top 20%
Non-Invasive Vital Sign Monitoring
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.