Simplified Lead Detection: Graphene-Based Potentiometric Sensors for Pb(II) Monitoring

Lead contamination remains a significant environmental and public health concern, creating a demand for analytical platforms that combine sensitivity, simplicity, and long-term stability. In this work, a graphene-containing molecular membrane matrix was developed for the fabrication of single-piece all-solid-state potentiometric sensors for Pb(II) detection. The sensing membrane consisted of poly(vinyl chloride), plasticizers, a Pb(II)-selective ionophore, lipophilic ionic sites, and dispersed graphene nanostructures, forming an integrated molecular sensing interface. Within the membrane phase, selective complexation of Pb(II) ions by the ionophore was coupled with graphene-assisted ion-to-electron transduction, enabling efficient signal generation without the need for a separate solid-contact layer. The influence of graphene incorporation and membrane thickness on sensor performance was systematically investigated. Among the tested configurations, a membrane prepared from 40 µL of sensing cocktail provided the best overall performance, combining high electrical capacitance, favorable surface properties, and superior potential stability. SEM imaging revealed a homogeneous membrane morphology without large graphene agglomerates, indicating effective dispersion of graphene within the polymer matrix. The optimized sensor exhibited a near-Nernstian slope of 30.3 mV dec−1, a linear response range from 1.0 × 10−7 to 1.0 × 10−2 M, a detection limit of 6.3 × 10−8 M, and a potential drift of only 0.35 mV h−1. These results demonstrate that direct incorporation of graphene into an ion-selective membrane is an effective strategy for constructing robust and scalable single-piece potentiometric sensors for Pb(II) monitoring and highlight the potential of developed membrane materials for electrochemical sensing applications.

Authors

Institutions

Publication Details

Journal
Sensors
Published
2026-08-26
DOI
https://doi.org/10.3390/s26175395
Primary Topic
Analytical Chemistry and Sensors
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Simplified Lead Detection: Graphene-Based Potentiometric Sensors for Pb(II) Monitoring

Nikola Lenar, Beata Paczosa‐Bator, Martyna Drużyńska
Sensors
Analytical Chemistry and Sensors
article

Simplified Lead Detection: Graphene-Based Potentiometric Sensors for Pb(II) Monitoring

Nikola Lenar, Beata Paczosa‐Bator, Martyna Drużyńska
article en

Abstract

Lead contamination remains a significant environmental and public health concern, creating a demand for analytical platforms that combine sensitivity, simplicity, and long-term stability. In this work, a graphene-containing molecular membrane matrix was developed for the fabrication of single-piece all-solid-state potentiometric sensors for Pb(II) detection. The sensing membrane consisted of poly(vinyl chloride), plasticizers, a Pb(II)-selective ionophore, lipophilic ionic sites, and dispersed graphene nanostructures, forming an integrated molecular sensing interface. Within the membrane phase, selective complexation of Pb(II) ions by the ionophore was coupled with graphene-assisted ion-to-electron transduction, enabling efficient signal generation without the need for a separate solid-contact layer. The influence of graphene incorporation and membrane thickness on sensor performance was systematically investigated. Among the tested configurations, a membrane prepared from 40 µL of sensing cocktail provided the best overall performance, combining high electrical capacitance, favorable surface properties, and superior potential stability. SEM imaging revealed a homogeneous membrane morphology without large graphene agglomerates, indicating effective dispersion of graphene within the polymer matrix. The optimized sensor exhibited a near-Nernstian slope of 30.3 mV dec−1, a linear response range from 1.0 × 10−7 to 1.0 × 10−2 M, a detection limit of 6.3 × 10−8 M, and a potential drift of only 0.35 mV h−1. These results demonstrate that direct incorporation of graphene into an ion-selective membrane is an effective strategy for constructing robust and scalable single-piece potentiometric sensors for Pb(II) monitoring and highlight the potential of developed membrane materials for electrochemical sensing applications.

SensorsVol. 26(17)
Jagiellonian University (PL), AGH University of Krakow (PL)
Akademia Górniczo-Hutnicza im. Stanislawa Staszica
Openalex Percentile: Top 20%
Analytical Chemistry and Sensors
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.