Safety and Efficacy of Keratorefractive Lenticule Extraction (KLEx) for High Myopia with the CLEAR Platform

Objectives: To assess the safety and efficacy of Keratorefractive Lenticule Extraction (KLEx) in patients with myopia ≥ 5 diopters (D). Methods: Retrospective study of KLEx procedures performed at Siena Eye Laser (Poggibonsi, Italy) with the CLEAR platform of the Ziemer Z8 femtosecond laser. Results: We included 137 eyes of 85 patients; mean age was 33.8 ± 8.3 years. Assessment at baseline showed a mean myopic error of −7.3 ± 1.4 D, a mean astigmatic error of 1.1 ± 0.8 D, and a mean spherical equivalent (SE) of −7.8 ± 1.6 D. Preoperative corrected distance visual acuity (CDVA) was 0.0 logMAR or better in all eyes. Mean corneal thickness was 510.0 ± 26.9 µm. At post-operative day 1 (POD1) uncorrected distance visual acuity (UDVA) was 0.1 ± 0.1 logMAR, with a mean residual SEQ of 0.1 ± 0.8 D. At 6 months follow-up, mean UDVA significantly increased to 0.0 ± 0.0 logMAR (p < 0.001), with a mean residual SE of −0.12 ± 0.7 D (p > 0.05 compared to POD1). At 24 months, the mean UDVA remained stable at 0.0 ± 0.0 logMAR, with a mean residual SE of −0.1 ± 0.4 D as manifest refraction (all p > 0.05 compared to 6 months). At 6 months and 2 years, the observed residual stromal bed (RSB) was 30 microns thicker than the RSB calculated by the Ziemer LDV Z8 software 2022. The difference between predicted (POZ) and effective (EOZ) optical zone correlated with the degree of myopia corrected (r = 0.6, p < 0.001). The difference between POZ and EOZ inversely correlated with astigmatic correction (r = −0.5, p < 0.001). Conclusions: In patients with high myopia, CLEAR showed good predictability and efficacy. Both UDVA and SE improved during the first 6 months, and remained stable at 2 years. The effective RSB was thicker than expected, and patients with high astigmatism achieved a larger EOZ.

Authors

Institutions

Publication Details

Journal
Journal of Clinical Medicine
Published
2026-08-26
DOI
https://doi.org/10.3390/jcm15176585
Primary Topic
Corneal surgery and disorders
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
article

Safety and Efficacy of Keratorefractive Lenticule Extraction (KLEx) for High Myopia with the CLEAR Platform

Matteo Posarelli, Tara Moore, Antonio Leccisotti, Lorenzo Azzaro et al.
Journal of Clinical Medicine
Corneal surgery and disorders
article

Safety and Efficacy of Keratorefractive Lenticule Extraction (KLEx) for High Myopia with the CLEAR Platform

Matteo Posarelli, Tara Moore, Antonio Leccisotti, Lorenzo Azzaro, Stefania V. Fields
article en

Abstract

Objectives: To assess the safety and efficacy of Keratorefractive Lenticule Extraction (KLEx) in patients with myopia ≥ 5 diopters (D). Methods: Retrospective study of KLEx procedures performed at Siena Eye Laser (Poggibonsi, Italy) with the CLEAR platform of the Ziemer Z8 femtosecond laser. Results: We included 137 eyes of 85 patients; mean age was 33.8 ± 8.3 years. Assessment at baseline showed a mean myopic error of −7.3 ± 1.4 D, a mean astigmatic error of 1.1 ± 0.8 D, and a mean spherical equivalent (SE) of −7.8 ± 1.6 D. Preoperative corrected distance visual acuity (CDVA) was 0.0 logMAR or better in all eyes. Mean corneal thickness was 510.0 ± 26.9 µm. At post-operative day 1 (POD1) uncorrected distance visual acuity (UDVA) was 0.1 ± 0.1 logMAR, with a mean residual SEQ of 0.1 ± 0.8 D. At 6 months follow-up, mean UDVA significantly increased to 0.0 ± 0.0 logMAR (p < 0.001), with a mean residual SE of −0.12 ± 0.7 D (p > 0.05 compared to POD1). At 24 months, the mean UDVA remained stable at 0.0 ± 0.0 logMAR, with a mean residual SE of −0.1 ± 0.4 D as manifest refraction (all p > 0.05 compared to 6 months). At 6 months and 2 years, the observed residual stromal bed (RSB) was 30 microns thicker than the RSB calculated by the Ziemer LDV Z8 software 2022. The difference between predicted (POZ) and effective (EOZ) optical zone correlated with the degree of myopia corrected (r = 0.6, p < 0.001). The difference between POZ and EOZ inversely correlated with astigmatic correction (r = −0.5, p < 0.001). Conclusions: In patients with high myopia, CLEAR showed good predictability and efficacy. Both UDVA and SE improved during the first 6 months, and remained stable at 2 years. The effective RSB was thicker than expected, and patients with high astigmatism achieved a larger EOZ.

Journal of Clinical MedicineVol. 15(17)
University of Siena (IT), University of Ulster (GB)
Openalex Percentile: Top 10%
Corneal surgery and disorders
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.