A Comparative Evaluation of Active Cooling and Passive Insulation Technologies for Thaw Mitigation During Permafrost Drilling

Permafrost thawing induced by heat transfer from circulating drilling fluid poses a significant threat to wellbore integrity and drilling safety in Arctic hydrocarbon exploration. The absence of clear application boundaries for the two primary mitigation strategies, passive insulation and active cooling, impedes the cost-effective selection of engineering measures. This study presents a comparative numerical evaluation of insulated-casing technology and refrigerant-fluid circulation technology using a coupled hydrothermal heat transfer model solved via the finite difference method. Passive insulation reduces thawed volume by increasing radial thermal resistance, with performance improving sharply as apparent thermal conductivity declines below 0.02 W/(m·K). At an optimal conductivity of 0.006 W/(m·K), insulated casing achieves a thawed volume of 2.3 m3 after 7 days, comparable to aggressive active cooling at −15 °C and 20 L/s, demonstrating its viability as an energy-free alternative. Active cooling offers superior operational controllability, yet its effectiveness hinges critically on inlet temperature; lowering this temperature exerts a dominant influence on thaw suppression, whereas increasing flow rate yields diminishing returns beyond 12.5 to 15.0 L/s. A critical caveat is that operating at 0 °C and 5 L/s paradoxically reverses the cooling effect and exacerbates thawing. Sensitivity analyses reveal that refrigerant-fluid circulation technology excels in permafrost layers up to 500 m, reducing thaw volume by a factor of two to three compared with high-performance insulation. This advantage diminishes for thicknesses exceeding 600 m, where insulated casing provides robust, thickness-independent protection. These findings establish a quantitative framework for context-specific technology selection, enabling engineers to balance thermal performance, operational controllability, and energy efficiency in permafrost drilling operations.

Authors

Institutions

Publication Details

Journal
Applied Sciences
Published
2026-08-26
DOI
https://doi.org/10.3390/app16178504
Primary Topic
Climate change and permafrost
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Comparative Evaluation of Active Cooling and Passive Insulation Technologies for Thaw Mitigation During Permafrost Drilling

Ruixue Zeng, Siyuan Sun, Shaotao Xu, Xu Liang et al.
Applied Sciences
Climate change and permafrost
article

A Comparative Evaluation of Active Cooling and Passive Insulation Technologies for Thaw Mitigation During Permafrost Drilling

Ruixue Zeng, Siyuan Sun, Shaotao Xu, Xu Liang, Bing Li, Zhihong Wang, Han Wang
article en

Abstract

Permafrost thawing induced by heat transfer from circulating drilling fluid poses a significant threat to wellbore integrity and drilling safety in Arctic hydrocarbon exploration. The absence of clear application boundaries for the two primary mitigation strategies, passive insulation and active cooling, impedes the cost-effective selection of engineering measures. This study presents a comparative numerical evaluation of insulated-casing technology and refrigerant-fluid circulation technology using a coupled hydrothermal heat transfer model solved via the finite difference method. Passive insulation reduces thawed volume by increasing radial thermal resistance, with performance improving sharply as apparent thermal conductivity declines below 0.02 W/(m·K). At an optimal conductivity of 0.006 W/(m·K), insulated casing achieves a thawed volume of 2.3 m3 after 7 days, comparable to aggressive active cooling at −15 °C and 20 L/s, demonstrating its viability as an energy-free alternative. Active cooling offers superior operational controllability, yet its effectiveness hinges critically on inlet temperature; lowering this temperature exerts a dominant influence on thaw suppression, whereas increasing flow rate yields diminishing returns beyond 12.5 to 15.0 L/s. A critical caveat is that operating at 0 °C and 5 L/s paradoxically reverses the cooling effect and exacerbates thawing. Sensitivity analyses reveal that refrigerant-fluid circulation technology excels in permafrost layers up to 500 m, reducing thaw volume by a factor of two to three compared with high-performance insulation. This advantage diminishes for thicknesses exceeding 600 m, where insulated casing provides robust, thickness-independent protection. These findings establish a quantitative framework for context-specific technology selection, enabling engineers to balance thermal performance, operational controllability, and energy efficiency in permafrost drilling operations.

Applied SciencesVol. 16(17)
Jilin University (CN), Ministry of Natural Resources (CN), China University of Geosciences (Beijing) (CN)
Ministry of Education of the People's Republic of China, Ministry of Science and Technology of the People's Republic of China
Affordable and clean energy
Openalex Percentile: Top 14%
Climate change and permafrost
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.