Comparative Evaluation of Tooth Type and Pulp Chamber Depth on the Accuracy of Endocrown Scans Acquired Using Various Intraoral Scanners

OBJECTIVE: To evaluate the effects of pulp chamber depth, tooth type, and intraoral scanner (IOS) on the accuracy of endocrown digital impressions. MATERIALS AND METHODS: Standardized endocrown preparations with 2 and 5 mm pulp chamber depths were performed on molar and premolar typodonts. Digital impressions were obtained using three IOSs (Dexis, iTero, and 3Shape). Reference scans were acquired using a laboratory scanner. Accuracy was assessed following best-fit alignment. Cavity base and axial regions were separately evaluated. Data were analyzed using Kruskal-Wallis and Dunn post hoc tests (α = 0.05). RESULTS: Pulp chamber depth, tooth type, and IOS significantly affected scanning accuracy (p < 0.05). Increasing cavity depth increased deviations at cavity base while reducing deviations at axial region. Premolar preparations with 5 mm depth exhibited the highest cavity base deviations (99.5-107.2 μm). At axial region, iTero demonstrated the lowest deviations (28.2 μm) in 5 mm depth molar preparations. Dexis and iTero showed comparable performance at cavity base. CONCLUSIONS: Effect of cavity depth was region-dependent, negatively affecting cavity base while improving accuracy at axial region. Molar preparations demonstrated superior cavity base trueness, whereas premolar preparations exhibited better axial region trueness. Deep premolar preparations represented the most challenging condition for accurate digital acquisition.

Authors

Institutions

Publication Details

Journal
Journal of Esthetic and Restorative Dentistry
Published
2026-08-26
DOI
https://doi.org/10.1111/jerd.70253
Primary Topic
Dental materials and restorations
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
article

Comparative Evaluation of Tooth Type and Pulp Chamber Depth on the Accuracy of Endocrown Scans Acquired Using Various Intraoral Scanners

Yunus Emre Özden, Zeynep Özkurt‐Kayahan, Mehmet Baybora Kayahan, Selen Erkul
Journal of Esthetic and Restorative Dentistry
Dental materials and restorations
article

Comparative Evaluation of Tooth Type and Pulp Chamber Depth on the Accuracy of Endocrown Scans Acquired Using Various Intraoral Scanners

Yunus Emre Özden, Zeynep Özkurt‐Kayahan, Mehmet Baybora Kayahan, Selen Erkul
article en

Abstract

OBJECTIVE: To evaluate the effects of pulp chamber depth, tooth type, and intraoral scanner (IOS) on the accuracy of endocrown digital impressions. MATERIALS AND METHODS: Standardized endocrown preparations with 2 and 5 mm pulp chamber depths were performed on molar and premolar typodonts. Digital impressions were obtained using three IOSs (Dexis, iTero, and 3Shape). Reference scans were acquired using a laboratory scanner. Accuracy was assessed following best-fit alignment. Cavity base and axial regions were separately evaluated. Data were analyzed using Kruskal-Wallis and Dunn post hoc tests (α = 0.05). RESULTS: Pulp chamber depth, tooth type, and IOS significantly affected scanning accuracy (p < 0.05). Increasing cavity depth increased deviations at cavity base while reducing deviations at axial region. Premolar preparations with 5 mm depth exhibited the highest cavity base deviations (99.5-107.2 μm). At axial region, iTero demonstrated the lowest deviations (28.2 μm) in 5 mm depth molar preparations. Dexis and iTero showed comparable performance at cavity base. CONCLUSIONS: Effect of cavity depth was region-dependent, negatively affecting cavity base while improving accuracy at axial region. Molar preparations demonstrated superior cavity base trueness, whereas premolar preparations exhibited better axial region trueness. Deep premolar preparations represented the most challenging condition for accurate digital acquisition.

Journal of Esthetic and Restorative Dentistry
Yeditepe University (TR), Bahçeşehir University (TR), Istanbul University-Cerrahpaşa (TR), Istanbul University (TR)
Openalex Percentile: Top 8%
Dental materials and restorations
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.