Urinary Aldosterone Analysed by LC-MS/MS vs Immunoassay for Diagnosis of Primary Aldosteronism

CONTEXT: The performance of 24-hour urinary aldosterone (24hr-UAldo) analysed by liquid chromatography-mass spectrometry (LC-MS/MS) (24hr-UAldo-LCMS) for diagnosis of primary aldosteronism (PA) is not established. OBJECTIVE: To assess the diagnostic performance of 24hr-UAldo-LCMS, vs that measured by immunoassay (24hr-UAldo-IA), for diagnosing PA. DESIGN, SETTING AND PATIENTS: A cohort study involving 182 prospectively-collected 24hr-urine samples from 167 patients who had hypertension with elevated plasma aldosterone-renin ratio and/or adrenalectomy for unilateral PA, 24-hour urinary sodium (24hr-UNa) measured and seated saline suppression test (SSST) performed, off interfering medications and on unrestricted dietary sodium, over a 5-year period at a tertiary centre. INTERVENTIONS AND MAIN OUTCOME MEASURES: 24hr-UAldo-LCMS was analysed in 182 samples and 24hr-UAldo-IA concurrently in a subset of 121 stored samples. Receiver operating characteristic curve analyses were performed to assess performance of 24hr-UAldo at various 24hr-UNa for diagnosing PA using SSST as the reference test. RESULTS: Mean ± SD 24hr-UAldo-LCMS was higher in cases with positive SSST (n = 127) vs those with negative SSST (n = 55) (50.6 ± 35.7 vs 20.8 ± 13.9 nmol/24 h; P < 0.05). 24hr-UAldo-LCMS ≥23.5 nmol/24 h had 92.1% sensitivity and 82.6% specificity (area under the curve [AUC] = 0.946), while a higher cut-off of ≥27.5 nmol/24 h provided a higher specificity (92.3%) with 78.9% sensitivity to identify PA in those with 24hr-UNa ≥190 mmol/24 h, the 24hr-UNa level with optimal 24hr-UAldo performance. The specificity of 24hr-UAldo-IA was inferior: 66.7% (92.3% sensitivity) at 24hr-UAldo-IA ≥24.5 nmol/24 h (AUC=0.81) and 77.8% (73% sensitivity) at 24hr-UAldo-IA ≥35.5 nmol/24 h, when 24hr-UNa ≥190 mmol/24 h. CONCLUSION: 24hr-UAldo-LCMS in the setting of 24hr-UNa ≥190 mmol/24 h can diagnose PA with high sensitivity and specificity, at lower cut-offs than 24hr-UAldo-IA.

Authors

Institutions

Publication Details

Journal
The Journal of Clinical Endocrinology & Metabolism
Published
2026-08-25
DOI
https://doi.org/10.1210/clinem/dgag349
Primary Topic
Hormonal Regulation and Hypertension
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Urinary Aldosterone Analysed by LC-MS/MS vs Immunoassay for Diagnosis of Primary Aldosteronism

Sheree Stoner, Brett C McWhinney, Michael Stowasser, Moe Thuzar et al.
The Journal of Clinical Endocrinology & Metabolism
Hormonal Regulation and Hypertension
article

Urinary Aldosterone Analysed by LC-MS/MS vs Immunoassay for Diagnosis of Primary Aldosteronism

Sheree Stoner, Brett C McWhinney, Michael Stowasser, Moe Thuzar, Jacobus Ungerer, Jun Yang, Elisabeth Ng, Jinwen He, Bo Li, Greg Ward, Diane Cowley, David Je, Alexandra Matthews
article en

Abstract

CONTEXT: The performance of 24-hour urinary aldosterone (24hr-UAldo) analysed by liquid chromatography-mass spectrometry (LC-MS/MS) (24hr-UAldo-LCMS) for diagnosis of primary aldosteronism (PA) is not established. OBJECTIVE: To assess the diagnostic performance of 24hr-UAldo-LCMS, vs that measured by immunoassay (24hr-UAldo-IA), for diagnosing PA. DESIGN, SETTING AND PATIENTS: A cohort study involving 182 prospectively-collected 24hr-urine samples from 167 patients who had hypertension with elevated plasma aldosterone-renin ratio and/or adrenalectomy for unilateral PA, 24-hour urinary sodium (24hr-UNa) measured and seated saline suppression test (SSST) performed, off interfering medications and on unrestricted dietary sodium, over a 5-year period at a tertiary centre. INTERVENTIONS AND MAIN OUTCOME MEASURES: 24hr-UAldo-LCMS was analysed in 182 samples and 24hr-UAldo-IA concurrently in a subset of 121 stored samples. Receiver operating characteristic curve analyses were performed to assess performance of 24hr-UAldo at various 24hr-UNa for diagnosing PA using SSST as the reference test. RESULTS: Mean ± SD 24hr-UAldo-LCMS was higher in cases with positive SSST (n = 127) vs those with negative SSST (n = 55) (50.6 ± 35.7 vs 20.8 ± 13.9 nmol/24 h; P < 0.05). 24hr-UAldo-LCMS ≥23.5 nmol/24 h had 92.1% sensitivity and 82.6% specificity (area under the curve [AUC] = 0.946), while a higher cut-off of ≥27.5 nmol/24 h provided a higher specificity (92.3%) with 78.9% sensitivity to identify PA in those with 24hr-UNa ≥190 mmol/24 h, the 24hr-UNa level with optimal 24hr-UAldo performance. The specificity of 24hr-UAldo-IA was inferior: 66.7% (92.3% sensitivity) at 24hr-UAldo-IA ≥24.5 nmol/24 h (AUC=0.81) and 77.8% (73% sensitivity) at 24hr-UAldo-IA ≥35.5 nmol/24 h, when 24hr-UNa ≥190 mmol/24 h. CONCLUSION: 24hr-UAldo-LCMS in the setting of 24hr-UNa ≥190 mmol/24 h can diagnose PA with high sensitivity and specificity, at lower cut-offs than 24hr-UAldo-IA.

The Journal of Clinical Endocrinology & Metabolism
Queensland Health (AU), The University of Queensland (AU), Princess Alexandra Hospital (AU), Hudson Institute of Medical Research (AU), Hypertension Institute (US), Princess Alexandra Hospital (GB), Sullivan Nicolaides Pathology (AU), Monash University (AU)
Good health and well-being
Openalex Percentile: Top 10%
Hormonal Regulation and Hypertension
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.