Wearable wrist-watch type cuff oscillometric blood pressure monitors: consensus statement by the European Society of Hypertension Working Group on blood pressure monitoring

Wearable wristwatch-type cuff oscillometric blood pressure (BP) monitors represent a new category of BP devices and are the first wearable monitors to use established cuff-oscillometric BP measurement technology. This consensus statement by the European Society of Hypertension Working Group on BP Monitoring reviews the published evidence on their design, accuracy, validation, clinical application, and remaining research questions. Of 281 articles identified through a systematic PubMed search, 26 were relevant. Several devices are currently available; however, only two have published validation studies performed according to established standards (Omron HeartGuide and Huawei Watch D/D2). Static validation studies generally showed acceptable accuracy, whereas data on 24-h ambulatory use, in special populations, and clinical applications remain limited. Potential advantages include self-initiated measurement at home, at work, and in other settings and conditions; more convenient and repeatable 24-h ambulatory monitoring; more convenient and accurate assessment of asleep BP; capture of stress-related and other BP-related episodes. However, proper wrist position, user adherence, ambulatory performance, and clinical applications require further investigation. More research is needed to establish the accuracy and clinical utility of these novel devices and their role in improving the diagnosis and management of hypertension.

Authors

Institutions

Publication Details

Journal
Journal of Hypertension
Published
2026-08-26
DOI
https://doi.org/10.1097/hjh.0000000000004415
Primary Topic
Blood Pressure and Hypertension Studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Wearable wrist-watch type cuff oscillometric blood pressure monitors: consensus statement by the European Society of Hypertension Working Group on blood pressure monitoring

Θωμάς Τσαγανός, Grzegorz Bilo, K. Asayama, Dagnóvar Aristizábal et al.
Journal of Hypertension
Blood Pressure and Hypertension Studies
article

Wearable wrist-watch type cuff oscillometric blood pressure monitors: consensus statement by the European Society of Hypertension Working Group on blood pressure monitoring

Θωμάς Τσαγανός, Grzegorz Bilo, K. Asayama, Dagnóvar Aristizábal, Christopher Clark, Tomas Bothe, Dean Picone, Alejandro De La Sierra, Daichi Shimbo, Jiguang Wang, Ariadni Menti, Anastasios Kollias, Yan Li, Gianfranco Parati, Aletta E. Schutte, George F. Stergiou, Richard McManus, Takayoshi Ohkubo, Paolo Palatini, Roland Asmar, Kazuomi Kario
article en

Abstract

Wearable wristwatch-type cuff oscillometric blood pressure (BP) monitors represent a new category of BP devices and are the first wearable monitors to use established cuff-oscillometric BP measurement technology. This consensus statement by the European Society of Hypertension Working Group on BP Monitoring reviews the published evidence on their design, accuracy, validation, clinical application, and remaining research questions. Of 281 articles identified through a systematic PubMed search, 26 were relevant. Several devices are currently available; however, only two have published validation studies performed according to established standards (Omron HeartGuide and Huawei Watch D/D2). Static validation studies generally showed acceptable accuracy, whereas data on 24-h ambulatory use, in special populations, and clinical applications remain limited. Potential advantages include self-initiated measurement at home, at work, and in other settings and conditions; more convenient and repeatable 24-h ambulatory monitoring; more convenient and accurate assessment of asleep BP; capture of stress-related and other BP-related episodes. However, proper wrist position, user adherence, ambulatory performance, and clinical applications require further investigation. More research is needed to establish the accuracy and clinical utility of these novel devices and their role in improving the diagnosis and management of hypertension.

Journal of HypertensionVol. 44(10)
Brighton and Sussex Medical School (GB), Leibniz University Hannover (DE), The University of Sydney (AU), University of Tasmania (AU), University of Padua (IT), Jichi Medical University (JP), National and Kapodistrian University of Athens (GR), University of Exeter (GB), Columbia University Irving Medical Center (US), University Hospital Mútua de Terrassa (ES), Municipality of Medellín (CO), The George Institute for Global Health (AU), Foundation for laboratory medicine (CH), Shanghai Institute of Hypertension (CN), IRCCS Istituto Auxologico Italiano (IT), Sotiria General Hospital (GR), University of Milano-Bicocca (IT), Teikyo University (JP)
Partnerships for the goals
Openalex Percentile: Top 10%
Blood Pressure and Hypertension Studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.