Development and Preclinical Evaluation of a Dual-Drug Implant for Long-Acting HIV Prevention and Contraception

Background/Objectives: Multipurpose prevention technologies (MPTs) that combine protection against HIV and unintended pregnancy can improve women’s health outcomes by simplifying use and enhancing adherence. We developed a long-acting (LA) implant for the simultaneous and sustained delivery of the antiretroviral islatravir (ISL) and the contraceptive hormone etonogestrel (ENG). Methods: Using extruded poly-ε-caprolactone (PCL) tubing, reservoir-style implants were fabricated and evaluated in three configurations: (Group 1) a two-segment implant formed by joining separate ISL- and ENG-containing tubes; (Group 2) a single tube divided into two drug compartments by a heat-sealed PCL spacer; (Group 3) separate single-drug implants. In vitro release was assessed in phosphate-buffered saline at 37 °C, and safety and pharmacokinetic (PK) profiles were evaluated in New Zealand White rabbits (n = 4/group) over approximately 90 days. Results: The average ISL daily in vitro release rates for Groups 1, 2, and 3 were 29 ± 5 µg/day, 18 ± 5 µg/day, and 47 ± 8 µg/day, respectively, and ENG daily in vitro release rates were 39 ± 9 µg/day, 41 ± 8 µg/day, and 33 ± 7 µg/day. From day 28 through the end of the study, median (IQR) plasma concentrations were 0.22 (0.18–0.27) ng/mL, 0.28 (0.24–0.33) ng/mL, and 0.31 (0.28–0.33) ng/mL for ISL in Groups 1, 2, and 3, respectively, and 0.26 (0.21–0.31) ng/mL, 0.25 (0.16–0.47) ng/mL, and 0.30 (0.23–0.38) ng/mL for ENG in Groups 1, 2 and 3, respectively. Implants across all groups were well tolerated and demonstrated favorable local tolerability over the 90-day dosing period. Conclusions: Integration of multiple indications into a single platform capable of sustained release over an extended duration holds potential to address persistent gaps in women’s sexual and reproductive health needs.

Authors

Institutions

Publication Details

Journal
Pharmaceutics
Published
2026-08-26
DOI
https://doi.org/10.3390/pharmaceutics18091060
Primary Topic
Reproductive Health and Contraception
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
article

Development and Preclinical Evaluation of a Dual-Drug Implant for Long-Acting HIV Prevention and Contraception

Sai Archana Krovi, Ellen Luecke, Amanda P. Schauer, Leah M. Johnson et al.
Pharmaceutics
Reproductive Health and Contraception
article

Development and Preclinical Evaluation of a Dual-Drug Implant for Long-Acting HIV Prevention and Contraception

Sai Archana Krovi, Ellen Luecke, Amanda P. Schauer, Leah M. Johnson, Greg Gatto, Rhonda Brand, Mackenzie L. Cottrell, Amanda Swistok, Leanna Levin
article en

Abstract

Background/Objectives: Multipurpose prevention technologies (MPTs) that combine protection against HIV and unintended pregnancy can improve women’s health outcomes by simplifying use and enhancing adherence. We developed a long-acting (LA) implant for the simultaneous and sustained delivery of the antiretroviral islatravir (ISL) and the contraceptive hormone etonogestrel (ENG). Methods: Using extruded poly-ε-caprolactone (PCL) tubing, reservoir-style implants were fabricated and evaluated in three configurations: (Group 1) a two-segment implant formed by joining separate ISL- and ENG-containing tubes; (Group 2) a single tube divided into two drug compartments by a heat-sealed PCL spacer; (Group 3) separate single-drug implants. In vitro release was assessed in phosphate-buffered saline at 37 °C, and safety and pharmacokinetic (PK) profiles were evaluated in New Zealand White rabbits (n = 4/group) over approximately 90 days. Results: The average ISL daily in vitro release rates for Groups 1, 2, and 3 were 29 ± 5 µg/day, 18 ± 5 µg/day, and 47 ± 8 µg/day, respectively, and ENG daily in vitro release rates were 39 ± 9 µg/day, 41 ± 8 µg/day, and 33 ± 7 µg/day. From day 28 through the end of the study, median (IQR) plasma concentrations were 0.22 (0.18–0.27) ng/mL, 0.28 (0.24–0.33) ng/mL, and 0.31 (0.28–0.33) ng/mL for ISL in Groups 1, 2, and 3, respectively, and 0.26 (0.21–0.31) ng/mL, 0.25 (0.16–0.47) ng/mL, and 0.30 (0.23–0.38) ng/mL for ENG in Groups 1, 2 and 3, respectively. Implants across all groups were well tolerated and demonstrated favorable local tolerability over the 90-day dosing period. Conclusions: Integration of multiple indications into a single platform capable of sustained release over an extended duration holds potential to address persistent gaps in women’s sexual and reproductive health needs.

PharmaceuticsVol. 18(9)
University of North Carolina at Chapel Hill (US), RTI International (US), Magee-Womens Research Institute (US)
Bill and Melinda Gates Foundation
Good health and well-being
Openalex Percentile: Top 8%
Reproductive Health and Contraception
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.