Investigation of drilling and necrosis zone performance of split point drills in surgical cortical bone drilling

The surgical bone drilling process is unavoidable in orthopedic, traumatological and dental applications for screw, plate and implant placement procedures. The mechanical and thermal effects generated during this process have a direct impact on both surgical success and post-operative recovery. The high axial forces, torque, and local temperature increases that occur during drilling can lead to serious clinical complications such as microcrack formation, thermal necrosis, implant loosening, and delayed bone healing. Therefore, optimizing the cutting tool geometry in bone drilling processes is one of the important focal points of current research. In this study, cortical bone drilling processes performed using split point drills with different geometric parameters and standard drills were investigated. The drilling force, torque, and thermal necrosis formation during drilling were simulated using the finite element method (FEM), and the obtained data were modelled using artificial neural networks (ANN). A high level of compatibility was achieved between the ANN model and the FEM results, with training and test correlation coefficients and mean error rates calculated as 0.99998, 0.99502 and 1.84%, respectively. The results showed that split point drills provided significantly lower drilling forces compared to standard drills. The combination of optimum design parameters, namely a 115-degree splitting angle, 0.25 mm split point web thickness, and 7-degree gashing rake angle, resulted in a 46.8% lower drilling force, 4.6% lower torque, and 5.2% lower thermal necrosis compared to the standard drill. These findings demonstrate that split point drill geometry offers significant advantages in surgical bone drilling applications.

Authors

Institutions

Publication Details

Journal
Biomedical Physics & Engineering Express
Published
2026-08-26
DOI
https://doi.org/10.1088/2057-1976/ae9eca
Primary Topic
Dental Implant Techniques and Outcomes
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
article

Investigation of drilling and necrosis zone performance of split point drills in surgical cortical bone drilling

Emre Çalışal, Kutay Aydın, Levent Uğur, Pinar Kızılışık
Biomedical Physics & Engineering Express
Dental Implant Techniques and Outcomes
article

Investigation of drilling and necrosis zone performance of split point drills in surgical cortical bone drilling

Emre Çalışal, Kutay Aydın, Levent Uğur, Pinar Kızılışık
article en

Abstract

The surgical bone drilling process is unavoidable in orthopedic, traumatological and dental applications for screw, plate and implant placement procedures. The mechanical and thermal effects generated during this process have a direct impact on both surgical success and post-operative recovery. The high axial forces, torque, and local temperature increases that occur during drilling can lead to serious clinical complications such as microcrack formation, thermal necrosis, implant loosening, and delayed bone healing. Therefore, optimizing the cutting tool geometry in bone drilling processes is one of the important focal points of current research. In this study, cortical bone drilling processes performed using split point drills with different geometric parameters and standard drills were investigated. The drilling force, torque, and thermal necrosis formation during drilling were simulated using the finite element method (FEM), and the obtained data were modelled using artificial neural networks (ANN). A high level of compatibility was achieved between the ANN model and the FEM results, with training and test correlation coefficients and mean error rates calculated as 0.99998, 0.99502 and 1.84%, respectively. The results showed that split point drills provided significantly lower drilling forces compared to standard drills. The combination of optimum design parameters, namely a 115-degree splitting angle, 0.25 mm split point web thickness, and 7-degree gashing rake angle, resulted in a 46.8% lower drilling force, 4.6% lower torque, and 5.2% lower thermal necrosis compared to the standard drill. These findings demonstrate that split point drill geometry offers significant advantages in surgical bone drilling applications.

Biomedical Physics & Engineering Express
Amasya Üniversitesi (TR)
Openalex Percentile: Top 8%
Dental Implant Techniques and Outcomes
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.