Background. In recent years, the use of ultrasound in the diagnosis of cellulite has grown substantially, making reproducible and validated ultrasound-based grading systems for stage III cellulite increasingly necessary to support their accurate application in both clinical practice and research. The Intagliata Echo-Cellulite (IEC) staging system identifies three morphological sub-types using high-frequency ultrasound. Objective. The study aims to evaluate the inter-rater reliability and test–retest reliability of the IEC staging system. Methods. This prospective, image-based reliability study included 150 women with stage III cellulite at a single center. Standardized ultrasound images acquired by an expert were independently rated by two non-expert raters in two sessions four weeks apart and compared with the expert’s ratings; the expert is also the developer of the IEC system. Results. For the primary outcome, IEC stage, both raters achieved almost perfect inter-rater agreement with the gold standard (Rater 1: κ = 0.926, 93.3%; Rater 2: κ = 0.985, 98.7%) and almost perfect test–retest consistency (Rater 1: κ = 0.840; Rater 2: κ = 0.817). Agreement on secondary ultrasound-based variables was more heterogeneous and consistently lower than for the composite IEC stage. Limitations. The image-based design provides an upper bound reliability estimate; additionally, the gold standard rater is the developer of the IEC system, which constrains the independence of the reference standard. Conclusions. Even when applied by untrained raters, the IEC staging system shows high inter-rater reliability and test–retest consistency. These findings further independent validation as a standardized grading tool in cellulite research and precision aesthetic medicine.

Authors

Institutions

Publication Details

Journal
Cosmetics
Published
2026-08-26
DOI
https://doi.org/10.3390/cosmetics13050218
Primary Topic
Body Contouring and Surgery
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Reliability and Consistency of the IEC Ultrasound Staging System for Stage III Cellulite: An Image-Based Validation Study

Maria Luisa Garo, Cristiana Saporosi, Dora Intagliata, Raffaella Benvenuto
Cosmetics
Body Contouring and Surgery
article

Reliability and Consistency of the IEC Ultrasound Staging System for Stage III Cellulite: An Image-Based Validation Study

Maria Luisa Garo, Cristiana Saporosi, Dora Intagliata, Raffaella Benvenuto
article en

Abstract

Background. In recent years, the use of ultrasound in the diagnosis of cellulite has grown substantially, making reproducible and validated ultrasound-based grading systems for stage III cellulite increasingly necessary to support their accurate application in both clinical practice and research. The Intagliata Echo-Cellulite (IEC) staging system identifies three morphological sub-types using high-frequency ultrasound. Objective. The study aims to evaluate the inter-rater reliability and test–retest reliability of the IEC staging system. Methods. This prospective, image-based reliability study included 150 women with stage III cellulite at a single center. Standardized ultrasound images acquired by an expert were independently rated by two non-expert raters in two sessions four weeks apart and compared with the expert’s ratings; the expert is also the developer of the IEC system. Results. For the primary outcome, IEC stage, both raters achieved almost perfect inter-rater agreement with the gold standard (Rater 1: κ = 0.926, 93.3%; Rater 2: κ = 0.985, 98.7%) and almost perfect test–retest consistency (Rater 1: κ = 0.840; Rater 2: κ = 0.817). Agreement on secondary ultrasound-based variables was more heterogeneous and consistently lower than for the composite IEC stage. Limitations. The image-based design provides an upper bound reliability estimate; additionally, the gold standard rater is the developer of the IEC system, which constrains the independence of the reference standard. Conclusions. Even when applied by untrained raters, the IEC staging system shows high inter-rater reliability and test–retest consistency. These findings further independent validation as a standardized grading tool in cellulite research and precision aesthetic medicine.

CosmeticsVol. 13(5)
University of Sannio (IT), Vanda Institute (KH), Fondazione Poliambulanza Istituto Ospedaliero (IT), University of Turin (IT)
Gender equality
Openalex Percentile: Top 8%
Body Contouring and Surgery
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.