Extracting the Unexpected: A 35-mm Curved Nail as an Intraocular Foreign Body

Objective:Unusual clinical course Background:Management of posterior segment intraocular foreign bodies is challenging, requiring the preservation of ocular integrity and restoring vision.Traumatic endophthalmitis occurs in 7% to 13% of penetrating injuries, particularly with coexisting intraocular foreign bodies.Managing posterior segment intraocular foreign bodies poses significant challenges due to their complex clinical presentation and the need to achieve multiple goals during treatment.This unusual case of a large metallic intraocular foreign body associated with traumatic cataract, retinal detachment, and endophthalmitis underscores the challenges of diagnosis and management. Case Report:A 31-year-old man presented with pain and vision loss in the left eye 7 days after penetrating trauma by a metallic foreign body.Examination showed visual acuity 20/20 (logMAR 0.00) in the right eye and hand movement (logMAR 3) in the left.There was a full-thickness inferior 2-mm corneal laceration with iris incarceration, anterior chamber reaction with fibrinous exudation, and a traumatic cataract, with no retinal view.Imaging confirmed the presence of an intraocular foreign body and endophthalmitis with an associated rhegmatogenous retinal detachment at the time of vitrectomy.The 35-mm foreign body was successfully removed.However, the intraocular foreign body was not detected initially on B-scan ultrasonography, reflecting the diagnostic and therapeutic challenges, as well as the importance of computed tomography imaging. Conclusions:This case report highlights the complexity of managing a large retained intraocular foreign body, underscoring the rarity of its size, complicated by endophthalmitis, traumatic cataract, and rhegmatogenous retinal detachment, emphasizing the importance of multimodal imaging, individualized treatment approaches, and continued research to improve management of similar conditions.

Authors

Institutions

Publication Details

Journal
American Journal of Case Reports
Published
2026-08-26
DOI
https://doi.org/10.12659/ajcr.953181
Primary Topic
Traumatic Ocular and Foreign Body Injuries
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Extracting the Unexpected: A 35-mm Curved Nail as an Intraocular Foreign Body

Rahaf A. Afandi, Najla A. Hafeezullah, Maher A. Aljohani, Adel S. Alahmadi
American Journal of Case Reports
Traumatic Ocular and Foreign Body Injuries
article

Extracting the Unexpected: A 35-mm Curved Nail as an Intraocular Foreign Body

Rahaf A. Afandi, Najla A. Hafeezullah, Maher A. Aljohani, Adel S. Alahmadi
article en

Abstract

Objective:Unusual clinical course Background:Management of posterior segment intraocular foreign bodies is challenging, requiring the preservation of ocular integrity and restoring vision.Traumatic endophthalmitis occurs in 7% to 13% of penetrating injuries, particularly with coexisting intraocular foreign bodies.Managing posterior segment intraocular foreign bodies poses significant challenges due to their complex clinical presentation and the need to achieve multiple goals during treatment.This unusual case of a large metallic intraocular foreign body associated with traumatic cataract, retinal detachment, and endophthalmitis underscores the challenges of diagnosis and management. Case Report:A 31-year-old man presented with pain and vision loss in the left eye 7 days after penetrating trauma by a metallic foreign body.Examination showed visual acuity 20/20 (logMAR 0.00) in the right eye and hand movement (logMAR 3) in the left.There was a full-thickness inferior 2-mm corneal laceration with iris incarceration, anterior chamber reaction with fibrinous exudation, and a traumatic cataract, with no retinal view.Imaging confirmed the presence of an intraocular foreign body and endophthalmitis with an associated rhegmatogenous retinal detachment at the time of vitrectomy.The 35-mm foreign body was successfully removed.However, the intraocular foreign body was not detected initially on B-scan ultrasonography, reflecting the diagnostic and therapeutic challenges, as well as the importance of computed tomography imaging. Conclusions:This case report highlights the complexity of managing a large retained intraocular foreign body, underscoring the rarity of its size, complicated by endophthalmitis, traumatic cataract, and rhegmatogenous retinal detachment, emphasizing the importance of multimodal imaging, individualized treatment approaches, and continued research to improve management of similar conditions.

American Journal of Case ReportsVol. 27
Ministry of Health (AE)
Peace, Justice and strong institutions
Openalex Percentile: Top 7%
Traumatic Ocular and Foreign Body Injuries
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Extracting the Unexpected: A 35-mm Curved Nail as an Intraocular Foreign Body — Rahaf A. Afandi, Najla A. Hafeezullah, et al. · American Journal of Case Reports (2026) | TGRS Research Map | TGRS