Predicting computed tomography angiography-measured arteriovenous fistula anastomosis angles using intraoperative non-contrast measurements: a prospective validation study

BACKGROUND: The anastomotic angle is a modifiable determinant of arteriovenous fistula (AVF) hemodynamics, maturation, and patency. Postoperative assessment typically relies on computed tomography angiography (CTA); however, factors such as contrast exposure, radiation, and cost limit its utility for repeated evaluations. In this study, we derived a correction factor for CTA-measured anastomotic angles. The primary aim was to validate the measurement method, rather than to establish a direct link between the angle and clinical outcomes. METHODS: This study collected intraoperative measurements from patients undergoing AVF surgeries and used these data to construct a predictive model for CTA-measured anastomosis angles. The model was validated using 20% of the data, with the remaining data used for model fitting. Bootstrap resampling (1,000 samples) was employed to estimate the mean squared error (MSE) and confidence intervals. RESULTS: The Bland-Altman plot indicated a mean difference of -16.90 between CTA and intraoperative measurements, with the majority of data points falling within the 95% limits of agreement. The Intraclass Correlation Coefficient was 0.79, suggesting acceptable reliability despite notable bias, while the Concordance Correlation Coefficient was 0.45, reflecting the impact of bias. Bootstrap validation yielded a mean MSE of 24.58 with a standard deviation of 15.17. The 95% percentile confidence interval was [2.66, 51.85]. CONCLUSION: This study provides a preliminary adjustment estimate to bridge the gap between intraoperative and CTA-measured angles. While not a fully developed predictive framework, this correction factor offers a practical, radiation-free method for surgeons to approximate the final anastomotic configuration.

Authors

Institutions

Publication Details

Journal
Renal Failure
Published
2026-08-25
DOI
https://doi.org/10.1080/0886022x.2026.2711149
Primary Topic
Central Venous Catheters and Hemodialysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Predicting computed tomography angiography-measured arteriovenous fistula anastomosis angles using intraoperative non-contrast measurements: a prospective validation study

Wei Liang, Tao Gong, Li Chen, Zibo Xiong et al.
Renal Failure
Central Venous Catheters and Hemodialysis
article

Predicting computed tomography angiography-measured arteriovenous fistula anastomosis angles using intraoperative non-contrast measurements: a prospective validation study

Wei Liang, Tao Gong, Li Chen, Zibo Xiong, Guang Yang, Ying Shan, Xiaoyan Huang, Zhidong Yuan, Yuhao Cao, Dandan Liao
article en

Abstract

BACKGROUND: The anastomotic angle is a modifiable determinant of arteriovenous fistula (AVF) hemodynamics, maturation, and patency. Postoperative assessment typically relies on computed tomography angiography (CTA); however, factors such as contrast exposure, radiation, and cost limit its utility for repeated evaluations. In this study, we derived a correction factor for CTA-measured anastomotic angles. The primary aim was to validate the measurement method, rather than to establish a direct link between the angle and clinical outcomes. METHODS: This study collected intraoperative measurements from patients undergoing AVF surgeries and used these data to construct a predictive model for CTA-measured anastomosis angles. The model was validated using 20% of the data, with the remaining data used for model fitting. Bootstrap resampling (1,000 samples) was employed to estimate the mean squared error (MSE) and confidence intervals. RESULTS: The Bland-Altman plot indicated a mean difference of -16.90 between CTA and intraoperative measurements, with the majority of data points falling within the 95% limits of agreement. The Intraclass Correlation Coefficient was 0.79, suggesting acceptable reliability despite notable bias, while the Concordance Correlation Coefficient was 0.45, reflecting the impact of bias. Bootstrap validation yielded a mean MSE of 24.58 with a standard deviation of 15.17. The 95% percentile confidence interval was [2.66, 51.85]. CONCLUSION: This study provides a preliminary adjustment estimate to bridge the gap between intraoperative and CTA-measured angles. While not a fully developed predictive framework, this correction factor offers a practical, radiation-free method for surgeons to approximate the final anastomotic configuration.

Renal FailureVol. 48(1)
Shenzhen Polytechnic University (CN), Southern University of Science and Technology (CN), Peking University Shenzhen Hospital (CN)
Good health and well-being
Openalex Percentile: Top 7%
Central Venous Catheters and Hemodialysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.