Specialized Drainage for Stray Current Control and Pipeline Integrity

Rapid urban transit development has increased crossings and proximity between railways and gas pipelines, intensifying direct current (DC) stray current interference. Periodic, high-amplitude DC currents from subway operation accelerate corrosion and threaten pipeline integrity. In China, a natural gas pipeline experienced dynamic interference currents up to 976 A/m2, and a sacrificial-anode drainage system proved ineffective. Conventional forced drainage was infeasible because of spatial, construction, and power constraints. This study1 demonstrated the application of a specialized assembled flexible anode integrated with a solar intelligent potentiostat for forced drainage, which proved to be effective, economical, feasible, and flexible, simplifying construction and improving overall performance.

Authors

Institutions

Publication Details

Journal
Materials Performance
Published
2026-08-26
DOI
https://doi.org/10.5006/mp2026_65_9-40
Primary Topic
Corrosion Behavior and Inhibition
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Specialized Drainage for Stray Current Control and Pipeline Integrity

Hai-Xing Feng, Yanqiang Liu, Luo Zhong-jiang, Hu Li-biao et al.
Materials Performance
Corrosion Behavior and Inhibition
article

Specialized Drainage for Stray Current Control and Pipeline Integrity

Hai-Xing Feng, Yanqiang Liu, Luo Zhong-jiang, Hu Li-biao, Yan Liu-qi, Guanjie Liu, Shu-Hui Ou, Jie Li
article en

Abstract

Rapid urban transit development has increased crossings and proximity between railways and gas pipelines, intensifying direct current (DC) stray current interference. Periodic, high-amplitude DC currents from subway operation accelerate corrosion and threaten pipeline integrity. In China, a natural gas pipeline experienced dynamic interference currents up to 976 A/m2, and a sacrificial-anode drainage system proved ineffective. Conventional forced drainage was infeasible because of spatial, construction, and power constraints. This study1 demonstrated the application of a specialized assembled flexible anode integrated with a solar intelligent potentiostat for forced drainage, which proved to be effective, economical, feasible, and flexible, simplifying construction and improving overall performance.

Materials PerformanceVol. 65(9)
Zhejiang Medicine (China) (CN)
Sustainable cities and communities
Openalex Percentile: Top 22%
Corrosion Behavior and Inhibition
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Specialized Drainage for Stray Current Control and Pipeline Integrity — Hai-Xing Feng, Yanqiang Liu, et al. · Materials Performance (2026) | TGRS Research Map | TGRS