The Effect of Non-Invasive Brain Stimulation on Running Performance and Inertial Measurement Unit-Derived Spatiotemporal Parameters in Endurance-Trained Runners

Integrating wearable motion sensing with neuromodulation may improve understanding of how alterations in neural excitability influence running performance and biomechanics. This study investigated whether intermittent theta burst stimulation (iTBS) applied to the primary motor cortex (M1), dorsolateral prefrontal cortex (DLPFC), or both regions influences running performance and sensor-derived spatiotemporal parameters during a 3000 m time-trial run. Ten endurance-trained runners (7 males) completed four stimulation conditions (M1, DLPFC, M1 + DLPFC, and sham) in a randomized, sham-controlled, repeated-measures crossover design. Running performance and spatiotemporal gait parameters were continuously monitored using wearable inertial measurement units (IMUs), with analyses conducted across the initial, steady-state, and final acceleration phases of the run. The M1 + DLPFC condition resulted in the fastest mean completion time, averaging approximately three seconds faster than sham. However, these differences were not statistically significant. Sensor-derived biomechanical measures revealed significantly higher running speeds and alterations in stride time and step frequency during the initial phase following combined stimulation compared with the other conditions. Ratings of perceived exertion and spatiotemporal variability did not differ between stimulation conditions. These findings demonstrate the utility of wearable IMUs for detecting subtle phase-specific changes in running biomechanics and suggest that combined stimulation of motor and cognitive control regions may influence early-stage running performance, warranting further investigation in larger cohorts. As the complete sample consisted of only ten runners, these findings are preliminary and require confirmation in a larger sample size.

Authors

Institutions

Publication Details

Journal
Sensors
Published
2026-08-26
DOI
https://doi.org/10.3390/s26175390
Primary Topic
Transcranial Magnetic Stimulation Studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

The Effect of Non-Invasive Brain Stimulation on Running Performance and Inertial Measurement Unit-Derived Spatiotemporal Parameters in Endurance-Trained Runners

Caroline Paquette, Isabella Sierra, Julie N. Côté, Alexandra Potvin‐Desrochers et al.
Sensors
Transcranial Magnetic Stimulation Studies
article

The Effect of Non-Invasive Brain Stimulation on Running Performance and Inertial Measurement Unit-Derived Spatiotemporal Parameters in Endurance-Trained Runners

Caroline Paquette, Isabella Sierra, Julie N. Côté, Alexandra Potvin‐Desrochers, Jenna C. Gibbs, Julien Clouette, Fabien A. Basset, Yiyang Chen, Henri Lajeunesse, Gleydciane Alexandre Fernandes
article en

Abstract

Integrating wearable motion sensing with neuromodulation may improve understanding of how alterations in neural excitability influence running performance and biomechanics. This study investigated whether intermittent theta burst stimulation (iTBS) applied to the primary motor cortex (M1), dorsolateral prefrontal cortex (DLPFC), or both regions influences running performance and sensor-derived spatiotemporal parameters during a 3000 m time-trial run. Ten endurance-trained runners (7 males) completed four stimulation conditions (M1, DLPFC, M1 + DLPFC, and sham) in a randomized, sham-controlled, repeated-measures crossover design. Running performance and spatiotemporal gait parameters were continuously monitored using wearable inertial measurement units (IMUs), with analyses conducted across the initial, steady-state, and final acceleration phases of the run. The M1 + DLPFC condition resulted in the fastest mean completion time, averaging approximately three seconds faster than sham. However, these differences were not statistically significant. Sensor-derived biomechanical measures revealed significantly higher running speeds and alterations in stride time and step frequency during the initial phase following combined stimulation compared with the other conditions. Ratings of perceived exertion and spatiotemporal variability did not differ between stimulation conditions. These findings demonstrate the utility of wearable IMUs for detecting subtle phase-specific changes in running biomechanics and suggest that combined stimulation of motor and cognitive control regions may influence early-stage running performance, warranting further investigation in larger cohorts. As the complete sample consisted of only ten runners, these findings are preliminary and require confirmation in a larger sample size.

SensorsVol. 26(17)
Memorial University of Newfoundland (CA), Jewish Rehabilitation Hospital (CA), McGill University Health Centre (CA), Cégep de l'Outaouais (CA), McGill University (CA), University of Memphis (US)
Openalex Percentile: Top 12%
Transcranial Magnetic Stimulation Studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.