Initial Experience with the Implementation of Continuous Glucose Monitoring in Inpatient Care

Introduction: High glycemic variability during hospitalization is associated with an increased risk of complications, prolonged hospital stay, higher costs, and mortality. Continuous glucose monitoring (CGM) enables ongoing measurement of interstitial fluid glucose concentration and reduces the incidence of hypo- and hyperglycemic episodes, glycemic variability, and the need for repeated capillary blood sampling in hospitalized patients. Aim To evaluate the implementation of CGM telemonitoring in the hospital setting, the indications for its use, the duration of monitoring in hospitalized patients with diabetes mellitus (DM), and to compare the economic aspects of CGM with standard monitoring using capillary blood sampling. Methodology: This retrospective observational study included 47 hospitalized patients with DM and non-diabetic hypoglycemia in whom a FreeStyle Libre 2 sensor was applied. The indications for CGM application, monitoring duration, economic costs, and the proportion of patients who continued using CGM after discharge home were analyzed. Given the retrospective and descriptive nature of the study, no formal statistical hypothesis testing was performed. Results CGM was implemented in 47 patients, of whom 43 were included in the analysis. The most common indication was metabolic decompensation of type 2 diabetes (43%). The mean monitoring duration was 8.5 ± 4.8 days, and 38% of patients continued using CGM after discharge. Although the direct costs of CGM are higher than those of capillary sampling, the difference decreases with longer monitoring duration and measurement frequency. Conclusion The use of CGM telemonitoring represents a safe supplementary method of glycemic monitoring in hospitalized patients with glycemic variability and differentiation of hypoglycemic states. Despite the higher direct costs, when the length of hospitalization and indirect benefits are taken into account, it may be a potentially cost-effective solution. In addition to increasing safety and individualization of glycemic management, its use was also associated with continued monitoring after discharge to home care in a significant proportion of patients.

Authors

Institutions

Publication Details

Journal
Bratislavské lekárske listy/Bratislava medical journal
Published
2026-11-25
DOI
https://doi.org/10.1007/s44411-026-00926-2
Primary Topic
Diabetes Management and Research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Initial Experience with the Implementation of Continuous Glucose Monitoring in Inpatient Care

Ingrid Dravecká, Ivica Lazúrová, Samuel Štellmach, S. Šikra
7 links
Bratislavské lekárske listy/Bratislava medical journal
Diabetes Management and Research
article

Initial Experience with the Implementation of Continuous Glucose Monitoring in Inpatient Care

Ingrid Dravecká, Ivica Lazúrová, Samuel Štellmach, S. Šikra
article en

Abstract

Introduction: High glycemic variability during hospitalization is associated with an increased risk of complications, prolonged hospital stay, higher costs, and mortality. Continuous glucose monitoring (CGM) enables ongoing measurement of interstitial fluid glucose concentration and reduces the incidence of hypo- and hyperglycemic episodes, glycemic variability, and the need for repeated capillary blood sampling in hospitalized patients. Aim To evaluate the implementation of CGM telemonitoring in the hospital setting, the indications for its use, the duration of monitoring in hospitalized patients with diabetes mellitus (DM), and to compare the economic aspects of CGM with standard monitoring using capillary blood sampling. Methodology: This retrospective observational study included 47 hospitalized patients with DM and non-diabetic hypoglycemia in whom a FreeStyle Libre 2 sensor was applied. The indications for CGM application, monitoring duration, economic costs, and the proportion of patients who continued using CGM after discharge home were analyzed. Given the retrospective and descriptive nature of the study, no formal statistical hypothesis testing was performed. Results CGM was implemented in 47 patients, of whom 43 were included in the analysis. The most common indication was metabolic decompensation of type 2 diabetes (43%). The mean monitoring duration was 8.5 ± 4.8 days, and 38% of patients continued using CGM after discharge. Although the direct costs of CGM are higher than those of capillary sampling, the difference decreases with longer monitoring duration and measurement frequency. Conclusion The use of CGM telemonitoring represents a safe supplementary method of glycemic monitoring in hospitalized patients with glycemic variability and differentiation of hypoglycemic states. Despite the higher direct costs, when the length of hospitalization and indirect benefits are taken into account, it may be a potentially cost-effective solution. In addition to increasing safety and individualization of glycemic management, its use was also associated with continued monitoring after discharge to home care in a significant proportion of patients.

Bratislavské lekárske listy/Bratislava medical journal
University of Pavol Jozef Šafárik (SK), Univerzitná Nemocnica Louisa Pasteura (SK)
Good health and well-being
Diabetes Management and Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon