A real-time image-guided six-degree-of-freedom internal-external correlation framework for motion monitoring on a standard linear accelerator

Abstract Objective. Real-time six-degree-of-freedom (6DoF) tumour motion monitoring is important for accurate stereotactic body radiotherapy (SBRT) of thoracic and abdominal cancer sites, yet existing approaches either require specialised imaging hardware or continuous fluoroscopic imaging. This study presents the development and first experimental implementation of a real-time image-guided 6DoF internal-external correlation (6D-IEC) modelling framework on a standard linear accelerator. Approach. The 6D-IEC framework estimates 6DoF tumour motion using a state-augmented linear correlation model between a 1DoF external respiratory monitor and internal fiducial marker positions, updated with intrafraction kV images every 3 seconds. Performance was characterised through two complementary evaluations: a prospective experimental investigation on a robotic motion platform, providing independent ground truth across eight patient-measured lung and liver motion traces (3 regular, 5 irregular); and a patient data study using intrafraction imaging data from three patients treated in the TROG 17.03 LARK liver SBRT trial (NCT02984566). 6DoF geometric error was quantified for both evaluations; software processing latency was measured in the experimental investigation. Main results. In the experimental investigation, mean ± SD geometric errors were 0.1±1.0 mm, 0.3±1.9 mm, and −0.3±1.4 mm along the left-right (LR), superior-inferior (SI), and anterior-posterior (AP) translational axes, and 0.4°±1.2°, −0.8°±1.0°, and −0.2°±0.8° around the corresponding rotational axes (rLR, rSI, rAP). Software processing latency was 190±80 ms. In the patient data study, errors were −0.5±0.7 mm, −1.2±2.5 mm, −0.1±1.0 mm (LR, SI, AP), and 1.1°±1.7°, −0.9°±1.5°, and −0.4°±1.6° (rLR, rSI, rAP). Significance. This work demonstrates that real-time 6DoF motion monitoring with clinically relevant accuracy is achievable on a standard linear accelerator without specialised hardware or continuous kV imaging. 6D-IEC infers tumour motion from an external signal between imaging updates, with accuracy contingent on internal-external correlation, but requires approximately 95% fewer intrafraction kV images than continuous fluoroscopic approaches. This has implications for broader access to real-time image-guided radiotherapy.

Authors

Institutions

Publication Details

Journal
Physics in Medicine and Biology
Published
2026-08-25
DOI
https://doi.org/10.1088/1361-6560/ae9e81
Primary Topic
Advanced Radiotherapy Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A real-time image-guided six-degree-of-freedom internal-external correlation framework for motion monitoring on a standard linear accelerator

John Kipritidis, Paul Keall, Nicholas Hardcastle, Jeremy Booth et al.
Physics in Medicine and Biology
Advanced Radiotherapy Techniques
article

A real-time image-guided six-degree-of-freedom internal-external correlation framework for motion monitoring on a standard linear accelerator

John Kipritidis, Paul Keall, Nicholas Hardcastle, Jeremy Booth, C. Sengupta, Alicja Kaczynska, Freeman Jin, Maegan Stewart
article en

Abstract

Abstract Objective. Real-time six-degree-of-freedom (6DoF) tumour motion monitoring is important for accurate stereotactic body radiotherapy (SBRT) of thoracic and abdominal cancer sites, yet existing approaches either require specialised imaging hardware or continuous fluoroscopic imaging. This study presents the development and first experimental implementation of a real-time image-guided 6DoF internal-external correlation (6D-IEC) modelling framework on a standard linear accelerator. Approach. The 6D-IEC framework estimates 6DoF tumour motion using a state-augmented linear correlation model between a 1DoF external respiratory monitor and internal fiducial marker positions, updated with intrafraction kV images every 3 seconds. Performance was characterised through two complementary evaluations: a prospective experimental investigation on a robotic motion platform, providing independent ground truth across eight patient-measured lung and liver motion traces (3 regular, 5 irregular); and a patient data study using intrafraction imaging data from three patients treated in the TROG 17.03 LARK liver SBRT trial (NCT02984566). 6DoF geometric error was quantified for both evaluations; software processing latency was measured in the experimental investigation. Main results. In the experimental investigation, mean ± SD geometric errors were 0.1±1.0 mm, 0.3±1.9 mm, and −0.3±1.4 mm along the left-right (LR), superior-inferior (SI), and anterior-posterior (AP) translational axes, and 0.4°±1.2°, −0.8°±1.0°, and −0.2°±0.8° around the corresponding rotational axes (rLR, rSI, rAP). Software processing latency was 190±80 ms. In the patient data study, errors were −0.5±0.7 mm, −1.2±2.5 mm, −0.1±1.0 mm (LR, SI, AP), and 1.1°±1.7°, −0.9°±1.5°, and −0.4°±1.6° (rLR, rSI, rAP). Significance. This work demonstrates that real-time 6DoF motion monitoring with clinically relevant accuracy is achievable on a standard linear accelerator without specialised hardware or continuous kV imaging. 6D-IEC infers tumour motion from an external signal between imaging updates, with accuracy contingent on internal-external correlation, but requires approximately 95% fewer intrafraction kV images than continuous fluoroscopic approaches. This has implications for broader access to real-time image-guided radiotherapy.

Physics in Medicine and Biology
Royal North Shore Hospital (AU), Peter MacCallum Cancer Centre (AU), North Shore Hospital (NZ), Institut des Maladies Génétiques Imagine (FR)
Openalex Percentile: Top 11%
Advanced Radiotherapy Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.