Analysis of cutting efficiency and superficial quality of resected root surface using different tools for apicoectomy: In vitro study

Abstract Introduction: In cases of endodontic treatment failures, retreatment is indicated, and when retreatment is not feasible, surgical intervention is performed. The present study aimed to evaluate the quality of apicectomies performed with Bladesonic and W1-O ultrasonic tips, comparing them with the #699 carbide drill; aspects related to cutting speed and postresection surface roughness were observed. Materials and Methods: Palatal and distobuccal roots from 36 extracted maxillary molars were used. The teeth were instrumented with rotary files up to #35/.04 in the distobuccal root and #50/.02 in the palatal root and filled with a thermoplasticizing technique with AH Plus cement. Teeth were randomly divided into three groups ( n = 12): Bladesonic, W1-O, and control (carbide #699 bur). After 15 days of filling, the specimens were apicectomized, at an angle of 90°, 3.0 mm from the root apex. The time required for root resection was recorded on a digital chronometer (0.01s); velocity was considered the ratio between time and area of each specimen. Roughness (μm) was measured by a blinded examiner regarding the apicoectomy method in a roughness meter calculated as a function of the arithmetic mean of the absolute values of the deviations from the profile within the evaluation length (Ra). The values obtained (speed and roughness) were submitted to the ANOVA analysis of variance and Tukey’s test ( P < 0.05); regression analysis was also applied among the characteristics analyzed. Results: The group prepared with the #699 drill showed shorter time for cutting in both roots. In turn, the group prepared with Bladesonic insert exhibited fewer rough surfaces. Conclusions: Under the conditions of the present study, it was possible to conclude that the type of instrument used in apicoectomy has an influence on the efficiency and quality of the cut.

Authors

Institutions

Publication Details

Journal
Saudi Endodontic Journal
Published
2026-08-25
DOI
https://doi.org/10.4103/sej.sej_277_25
Primary Topic
Endodontics and Root Canal Treatments
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
article

Analysis of cutting efficiency and superficial quality of resected root surface using different tools for apicoectomy: In vitro study

Thaine Oliveira Lima, Márcia Eugênia de Sousa Damasceno Feitosa, Murilo Priori Alcalde, Rodrigo Ricci Vivan et al.
Saudi Endodontic Journal
Endodontics and Root Canal Treatments
article

Analysis of cutting efficiency and superficial quality of resected root surface using different tools for apicoectomy: In vitro study

Thaine Oliveira Lima, Márcia Eugênia de Sousa Damasceno Feitosa, Murilo Priori Alcalde, Rodrigo Ricci Vivan, Bruno Carvalho de Vasconcelos, Ana Grasiela Limoeiro, Nathalia Maria Brigido Rabelo, Marco Antônio Húngaro Duarte, Suyane Maria Luna-Cruz
article en

Abstract

Abstract Introduction: In cases of endodontic treatment failures, retreatment is indicated, and when retreatment is not feasible, surgical intervention is performed. The present study aimed to evaluate the quality of apicectomies performed with Bladesonic and W1-O ultrasonic tips, comparing them with the #699 carbide drill; aspects related to cutting speed and postresection surface roughness were observed. Materials and Methods: Palatal and distobuccal roots from 36 extracted maxillary molars were used. The teeth were instrumented with rotary files up to #35/.04 in the distobuccal root and #50/.02 in the palatal root and filled with a thermoplasticizing technique with AH Plus cement. Teeth were randomly divided into three groups ( n = 12): Bladesonic, W1-O, and control (carbide #699 bur). After 15 days of filling, the specimens were apicectomized, at an angle of 90°, 3.0 mm from the root apex. The time required for root resection was recorded on a digital chronometer (0.01s); velocity was considered the ratio between time and area of each specimen. Roughness (μm) was measured by a blinded examiner regarding the apicoectomy method in a roughness meter calculated as a function of the arithmetic mean of the absolute values of the deviations from the profile within the evaluation length (Ra). The values obtained (speed and roughness) were submitted to the ANOVA analysis of variance and Tukey’s test ( P < 0.05); regression analysis was also applied among the characteristics analyzed. Results: The group prepared with the #699 drill showed shorter time for cutting in both roots. In turn, the group prepared with Bladesonic insert exhibited fewer rough surfaces. Conclusions: Under the conditions of the present study, it was possible to conclude that the type of instrument used in apicoectomy has an influence on the efficiency and quality of the cut.

Saudi Endodontic JournalVol. 16(3)
Universidade de São Paulo (BR), Universidade Federal do Ceará (BR)
Openalex Percentile: Top 8%
Endodontics and Root Canal Treatments
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.