Design Considerations of Inductive AC Interference Mitigation Techniques

Electromagnetic induction is the primary interference effect of a high-voltage transmission line on a buried steel pipeline during normal steady state operation. The operating current directly affects the level of electromagnetic interference, which can induce an alternating current (AC) voltage and corresponding current in the pipeline. This induced AC potential may present a safety hazard to personnel and can contribute to AC corrosion of the pipeline. Problems arise when alternating currents above the defined limits are present on a pipeline, even if the cathodic protection (CP) levels are satisfactory and meet the criteria defined in ISO 15589-11 and ISO 218572. Much effort has been made in the last decades to define acceptable AC interference levels for carbon steel under CP conditions.3, 4, 5, 6, 7, 8, 9, 10, 11 This article discusses CP design considerations for pipelines when AC interference is present.

Authors

Institutions

Publication Details

Journal
Materials Performance
Published
2026-08-26
DOI
https://doi.org/10.5006/mp2026_65_9-22
Primary Topic
Electrical Fault Detection and Protection
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Design Considerations of Inductive AC Interference Mitigation Techniques

Ahmed Magdy Wahba Mahgoub
Materials Performance
Electrical Fault Detection and Protection
article

Design Considerations of Inductive AC Interference Mitigation Techniques

Ahmed Magdy Wahba Mahgoub
article en

Abstract

Electromagnetic induction is the primary interference effect of a high-voltage transmission line on a buried steel pipeline during normal steady state operation. The operating current directly affects the level of electromagnetic interference, which can induce an alternating current (AC) voltage and corresponding current in the pipeline. This induced AC potential may present a safety hazard to personnel and can contribute to AC corrosion of the pipeline. Problems arise when alternating currents above the defined limits are present on a pipeline, even if the cathodic protection (CP) levels are satisfactory and meet the criteria defined in ISO 15589-11 and ISO 218572. Much effort has been made in the last decades to define acceptable AC interference levels for carbon steel under CP conditions.3, 4, 5, 6, 7, 8, 9, 10, 11 This article discusses CP design considerations for pipelines when AC interference is present.

Materials PerformanceVol. 65(9)
Saudi Aramco (Saudi Arabia) (SA)
Openalex Percentile: Top 19%
Electrical Fault Detection and Protection
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.