Temperature field analysis and thermal management optimization of the free piston engine generator based on electromagnetic-thermal coupling

The free piston engine generator is a highly promising energy conversion system characterized by high efficiency, high power density, and wide fuel adaptability. However, its compact design, extreme operating conditions, and complex multi-source thermal interactions pose serious challenges to thermal management. This study develops a multi-physics coupled temperature field model considering actual operating conditions and verifies its accuracy through experiments. Based on the validated model, the temperature characteristics and heat transfer paths of key components are analyzed. The heat dissipation performance and applicable boundaries of different cooling methods are evaluated. To address the identified thermal management limitations, optimization strategies are proposed from three aspects: heat source suppression, heat path interruption, and heat dissipation enhancement. Results indicate that during the cold start stage, the average thrust should be limited to below 280 N under natural cooling, while forced air cooling can effectively suppress temperature rise at room temperature. During the power generation stage, an inlet wind velocity of at least 5 m/s is required to maintain the maximum temperature of the linear generator below 100 °C. Although water cooling can significantly reduce the overall temperature, localized hotspots remain at the ends of the mover and connecting rod regions. The effect of the cooling water velocity on temperature exhibits a diminishing return trend, with the cooling effect approaching saturation when the velocity exceeds 3 m/s. Using low thermal conductivity connecting rod materials can effectively reduce heat conduction, but the adverse impact on piston heat dissipation should be considered. Overall thermal safety can be ensured by controlling the average piston temperature below 147 °C and enhancing surface convective heat transfer.

Authors

Institutions

Publication Details

Journal
Case Studies in Thermal Engineering
Published
2026-08-25
DOI
https://doi.org/10.1016/j.csite.2026.108449
Primary Topic
Advanced Thermodynamic Systems and Engines
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Temperature field analysis and thermal management optimization of the free piston engine generator based on electromagnetic-thermal coupling

Guanfu Li, Yidi Wei, Huihua Feng, Bin Xu et al.
Case Studies in Thermal Engineering
Advanced Thermodynamic Systems and Engines
article

Temperature field analysis and thermal management optimization of the free piston engine generator based on electromagnetic-thermal coupling

Guanfu Li, Yidi Wei, Huihua Feng, Bin Xu, Zhengxing Zuo, Boru Jia, Yuguo Ma, Jian Li, Haitao Lin
article en

Abstract

The free piston engine generator is a highly promising energy conversion system characterized by high efficiency, high power density, and wide fuel adaptability. However, its compact design, extreme operating conditions, and complex multi-source thermal interactions pose serious challenges to thermal management. This study develops a multi-physics coupled temperature field model considering actual operating conditions and verifies its accuracy through experiments. Based on the validated model, the temperature characteristics and heat transfer paths of key components are analyzed. The heat dissipation performance and applicable boundaries of different cooling methods are evaluated. To address the identified thermal management limitations, optimization strategies are proposed from three aspects: heat source suppression, heat path interruption, and heat dissipation enhancement. Results indicate that during the cold start stage, the average thrust should be limited to below 280 N under natural cooling, while forced air cooling can effectively suppress temperature rise at room temperature. During the power generation stage, an inlet wind velocity of at least 5 m/s is required to maintain the maximum temperature of the linear generator below 100 °C. Although water cooling can significantly reduce the overall temperature, localized hotspots remain at the ends of the mover and connecting rod regions. The effect of the cooling water velocity on temperature exhibits a diminishing return trend, with the cooling effect approaching saturation when the velocity exceeds 3 m/s. Using low thermal conductivity connecting rod materials can effectively reduce heat conduction, but the adverse impact on piston heat dissipation should be considered. Overall thermal safety can be ensured by controlling the average piston temperature below 147 °C and enhancing surface convective heat transfer.

Case Studies in Thermal EngineeringVol. 86
Beijing Institute of Technology (CN)
National Natural Science Foundation of China, Natural Science Foundation of Beijing Municipality
Affordable and clean energy
Openalex Percentile: Top 19%
Advanced Thermodynamic Systems and Engines
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.