Evaluation of filter substrates for concurrent optical photothermal infrared and Raman spectroscopy in microplastic analysis

Abstract Optical photothermal infrared (O-PTIR) spectroscopy is an emerging technique to analyze submicron mid-infrared absorption. It can be combined with concurrent, co-located Raman spectroscopy on the same instrument platform, offering considerable potential for microplastic analysis. However, since measurements are typically performed directly on collection filters, substrate selection becomes a critical yet un-examined factor for these concurrent modalities. Here, we characterized nine commercially available filter substrates, namely Anodisc, silicon, gold-coated PET, gold-coated PC, silver, glass and quartz microfiber, PC, and cellulose, for O-PTIR and Raman analysis using 14 µm and 7 µm PMMA microplastic beads. Spectral fidelity was quantified via hit quality indices against a CaF 2 reference. Our results show that substrate suitability is governed by modality-specific requirements. O-PTIR demands mid-infrared spectral neutrality and is additionally sensitive to the substrate surface, whereas the quality of Raman spectra primarily depends on the absence of substrate Raman bands. Beyond spectral match quality, the reproducibility of PMMA spectra is consistently higher in the Raman channel than in the O-PTIR channel. This difference is attributed to O-PTIR’s sensitivity to local thermal contact and surface morphology, which introduce measurement variability absent in direct Raman scattering. Of the tested substrates, Anodisc and gold-coated PET performed the best in both modalities and with both particle sizes. These findings demonstrate that recommendations for substrates established for conventional FTIR or Raman microscopy cannot be transferred directly to O-PTIR. They also provide an evidence-based framework for selecting substrates in multimodal microplastic analysis workflows.

Authors

Institutions

Publication Details

Journal
Analytical and Bioanalytical Chemistry
Published
2026-08-25
DOI
https://doi.org/10.1007/s00216-026-06735-4
Primary Topic
Thermography and Photoacoustic Techniques
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Evaluation of filter substrates for concurrent optical photothermal infrared and Raman spectroscopy in microplastic analysis

Shiwani Shiwani, Iwan W. Schie, Shravan Raghunathan, Christoph Krafft et al.
Analytical and Bioanalytical Chemistry
Thermography and Photoacoustic Techniques
article

Evaluation of filter substrates for concurrent optical photothermal infrared and Raman spectroscopy in microplastic analysis

Shiwani Shiwani, Iwan W. Schie, Shravan Raghunathan, Christoph Krafft, Jürgen Popp
article en

Abstract

Abstract Optical photothermal infrared (O-PTIR) spectroscopy is an emerging technique to analyze submicron mid-infrared absorption. It can be combined with concurrent, co-located Raman spectroscopy on the same instrument platform, offering considerable potential for microplastic analysis. However, since measurements are typically performed directly on collection filters, substrate selection becomes a critical yet un-examined factor for these concurrent modalities. Here, we characterized nine commercially available filter substrates, namely Anodisc, silicon, gold-coated PET, gold-coated PC, silver, glass and quartz microfiber, PC, and cellulose, for O-PTIR and Raman analysis using 14 µm and 7 µm PMMA microplastic beads. Spectral fidelity was quantified via hit quality indices against a CaF 2 reference. Our results show that substrate suitability is governed by modality-specific requirements. O-PTIR demands mid-infrared spectral neutrality and is additionally sensitive to the substrate surface, whereas the quality of Raman spectra primarily depends on the absence of substrate Raman bands. Beyond spectral match quality, the reproducibility of PMMA spectra is consistently higher in the Raman channel than in the O-PTIR channel. This difference is attributed to O-PTIR’s sensitivity to local thermal contact and surface morphology, which introduce measurement variability absent in direct Raman scattering. Of the tested substrates, Anodisc and gold-coated PET performed the best in both modalities and with both particle sizes. These findings demonstrate that recommendations for substrates established for conventional FTIR or Raman microscopy cannot be transferred directly to O-PTIR. They also provide an evidence-based framework for selecting substrates in multimodal microplastic analysis workflows.

Analytical and Bioanalytical Chemistry
Helmholtz Institute Jena (DE), Carl Zeiss (Germany) (DE), Leibniz Institute of Photonic Technology (DE), Friedrich Schiller University Jena (DE)
European Commission, Deutsche Forschungsgemeinschaft, H2020 Marie Skłodowska-Curie Actions
Openalex Percentile: Top 17%
Thermography and Photoacoustic Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.